Automated diabetic retinopathy detection in smartphone-based fundus photography using artificial intelligence
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
To assess the role of artificial intelligence (AI)-based automated software for detection of diabetic retinopathy (DR) and sight-threatening DR (STDR) by fundus photography taken using a smartphone-based device and validate it against ophthalmologist’s grading. Three hundred and one patients with type 2 diabetes underwent retinal photography with Remidio ‘Fundus on phone’ (FOP), a smartphone-based device, at a tertiary care diabetes centre in India. Grading of DR was performed by the ophthalmologists using International Clinical DR (ICDR) classification scale. STDR was defined by the presence of severe non-proliferative DR, proliferative DR or diabetic macular oedema (DME). The retinal photographs were graded using a validated AI DR screening software (EyeArt TM ) designed to identify DR, referable DR (moderate non-proliferative DR or worse and/or DME) or STDR. The sensitivity and specificity of automated grading were assessed and validated against the ophthalmologists’ grading. Retinal images of 296 patients were graded. DR was detected by the ophthalmologists in 191 (64.5%) and by the AI software in 203 (68.6%) patients while STDR was detected in 112 (37.8%) and 146 (49.3%) patients, respectively. The AI software showed 95.8% (95% CI 92.9–98.7) sensitivity and 80.2% (95% CI 72.6–87.8) specificity for detecting any DR and 99.1% (95% CI 95.1–99.9) sensitivity and 80.4% (95% CI 73.9–85.9) specificity in detecting STDR with a kappa agreement of k = 0.78 ( p < 0.001) and k = 0.75 ( p < 0.001), respectively. Automated AI analysis of FOP smartphone retinal imaging has very high sensitivity for detecting DR and STDR and thus can be an initial tool for mass retinal screening in people with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Image acquisition was often performed by trained non-physician staff (technicians, optometrists, nurses, paramedics), while final grading was typically carried out by ophthalmologists or retinal specialists (22/30 studies) [8–13, 15, 16, 18, 21, 22, 24, 26, 27, 30–37]”
From Diabetic retinopathy screening model in low and middle-income countries: a scoping review (2025) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, a hybrid approach—non-mydriatic screening with selective mydriasis for ungradable images—might optimizes accuracy and workflow [21, 43–45].”
From Diabetic retinopathy screening model in low and middle-income countries: a scoping review (2025) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Recent advancements include the use of CNN architectures like VGGNet [23] and ResNet [32], achieving high AUCs for referable DR up to 0.97 [21, 23].”
From Diabetic retinopathy screening model in low and middle-income countries: a scoping review (2025) · cites this paper as [21]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Remote grading of retinal images is widely utilized, with 18 out of 30 studies relying on this approach [10, 15, 16, 18, 21–27, 29–35, 37]”
From Diabetic retinopathy screening model in low and middle-income countries: a scoping review (2025) · cites this paper as [21]
The cited source says what the claim attributes to it.
In the citing paper
“Various severity scales are used to classify diabetic retinopathy (DR), with the International Clinical Diabetic Retinopathy (ICDR) severity scale being the most commonly utilized in 15 out of 30 studies [9, 11–13, 15, 18, 21–23, 32, 34–36].”
From Diabetic retinopathy screening model in low and middle-income countries: a scoping review (2025) · cites this paper as [21]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697 · cited 5×
“Deep learning/AI for detection of DR happens by machine learning by providing thousands of retinal images of varying grades of DR to the system for learning [7, 8].”
BackgroundMethodResultInfluential(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402 · cited 1×
“[18] done in Singapore with multiple retinal images taken with conventional fundus cameras from multi-ethnic cohorts of people with diabetes, their algorithm showed a high sensitivity and specificity for”
BackgroundFong, D. S., Aiello, L. P., Ferris, F. L., & Klein, R. (2004) · Diabetes Care · doi:10.2337/diacare.27.10.2540 · Cited by 640
Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Russo, A., Morescalchi, F., Costagliola, C., Delcassi, L., & Semeraro, F. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.11.008 · Cited by 177
Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173 · cited 4×
“Retinal photography with grading and interpretation by ophthalmologists/retina specialists and trained graders is widely accepted for screening for DR [4, 12, 13].”
BackgroundMethodResultInfluentialSelf-citationThe Cost–Utility of Telemedicine to Screen for Diabetic Retinopathy in India
Rachapelle, S., Legood, R., Alavi, Y., Lindfield, R., Sharma, T., Kuper, H., & Polack, S. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.09.002 · Cited by 171
Ahmed, J., Ward, T. P., Bursell, S.-E., Aiello, L. M., Cavallerano, J. D., & Vigersky, R. A. (2006) · Diabetes Care · doi:10.2337/dc06-0295 · Cited by 152
Cited by
Items 101–200 of 556
Najjar, R. (2024) · Biomedical engineering · doi:10.5772/intechopen.114142 · Cited by 37
Artificial Intelligence in Ophthalmology: Evolutions in Asia
Ruamviboonsuk, P., Cheung, C. Y.-L., Zhang, X., Raman, R., Park, S. J., & Ting, D. S. W. (2020) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/01.apo.0000656980.41190.bf · Cited by 37
Hao, S., Liu, C., Li, N., Wu, Y., Li, D., Gao, Q., Yuan, Z., Li, G., Li, H., Yang, J., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275983 · Cited by 37
A Review of Advancements and Evidence Gaps in Diabetic Retinopathy Screening Models
Pearce, E., & Sivaprasad, S. (2020) · Clinical ophthalmology · doi:10.2147/opth.s267521 · Cited by 37
Teng, C. W., Patel, S. D., Barkmeier, A. J., Liu, T. Y. A., Myung, D., Henderer, J., Liu, J., Hansen, E., & Al-Aswad, L. A. (2026) · Ophthalmology Science · doi:10.1016/j.xops.2025.100935 · Cited by 36
Urina‐Triana, M., Piñeres-Melo, M. A., Mantilla-Morrón, M., Butt, S. A., Galeano-Muñoz, L., Naz, S., & Ariza-Colpas, P. (2024) · IEEE Access · doi:10.1109/access.2024.3378277 · Cited by 37
Clinical Applications and Future Directions of Smartphone Fundus Imaging
Ahn, S. J., & Kim, Y. H. (2024) · Diagnostics · doi:10.3390/diagnostics14131395 · Cited by 36
Sedova, A., Hajdu, D., Datlinger, F., Steiner, I., Neschi, M., Aschauer, J., Gerendas, B. S., Schmidt-Erfurth, U., & Pollreisz, A. (2022) · Eye · doi:10.1038/s41433-021-01912-4 · Cited by 35
Geldsetzer, P., Flores, S., Wang, G., Flores, B. E. I., Rogers, A. B., Bunker, A., Chang, A. Y., & Tisdale, R. L. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00644-3 · Cited by 35
Accelerating ophthalmic artificial intelligence research: the role of an open access data repository
Kras, A., Celi, L. A., & Miller, J. B. (2020) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000678 · Cited by 35
Kim, T. N., Aaberg, M. T., Li, P., Davila, J. R., Bhaskaranand, M., Bhat, S., Ramachandra, C. A., Solanki, K. V., Myers, F., Reber, C. D., et al. (2020) · Eye · doi:10.1038/s41433-020-0849-5 · Cited by 35
Imaging Modalities Employed in Diabetic Retinopathy Screening: A Review and Meta-Analysis
Kanclerz, P., Tuuminen, R., & Khoramnia, R. (2021) · Diagnostics · doi:10.3390/diagnostics11101802 · Cited by 35
Srivastava, N., Verma, S., Singh, A., Shukla, P., Singh, Y., Oza, A. D., Kaur, T., Chowdhury, S., Kapoor, M., & Yadav, A. N. (2024) · DARU Journal of Pharmaceutical Sciences · doi:10.1007/s40199-024-00548-5 · Cited by 36
Progress of artificial intelligence in diabetic retinopathy screening
Wang, Y., Yang, J., Yang, J., Zhao, X., Chen, Y., & Yu, W. (2020) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3414 · Cited by 34
Tahir, H. N., Ullah, N., Tahir, M., Domnic, I. S., Prabhakar, R., Meerasa, S. S., AbdElneam, A. I., Tahir, S., & Ali, Y. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2025.1519768 · Cited by 32
Smartphone Eye Examination: Artificial Intelligence and Telemedicine
Vilela, M. A. P., Arrigo, A., Parodi, M. B., & Mengue, C. D. S. (2024) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2023.0041 · Cited by 32
Sajid, M. Z., Qureshi, I., Abbas, Q., Albathan, M., Shaheed, K., Youssef, A., Ferdous, S., & Hussain, A. (2023) · Diagnostics · doi:10.3390/diagnostics13081439 · Cited by 32
Nunez do Rio, J. M., Nderitu, P., Raman, R., Rajalakshmi, R., Kim, R., Rani, P. K., Sivaprasad, S., Bergeles, C., for the SMART India Study Group, Raman, R., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-28347-z · Cited by 31
Self-citationBi, Z., Li, J., Liu, Q., & Fang, Z. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1485311 · Cited by 31
Accuracy and feasibility with AI-assisted OCT in retinal disorder community screening
Bai, J., Wan, Z., Li, P., Chen, L., Wang, J., Fan, Y., Chen, X., Peng, Q., & Gao, P. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.1053483 · Cited by 31
Digital image processing software for diagnosing diabetic retinopathy from fundus photograph
Ratanapakorn, T., Daengphoonphol, A., Eua-Anant, N., & Yospaiboon, Y. (2019) · Clinical ophthalmology · doi:10.2147/opth.s195617 · Cited by 31
Commentary: Rise of machine learning and artificial intelligence in ophthalmology
Akkara, J., & Kuriakose, A. (2019) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_622_19 · Cited by 30
Hainsworth, D. P., Gangula, A., Ghoshdastidar, S., Kannan, R., & Upendran, A. (2020) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2020.01.032 · Cited by 29
Chen, Y., Zhao, W., Yi, S., & Liu, J. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1174080 · Cited by 28
Wroblewski, J. J., Sánchez-Buenfil, E., Inciarte, M., Berdia, J., Blake, L. R., Wroblewski, S., Patti, A., Suter, G., & Sanborn, G. E. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231194644 · Cited by 28
Malerbi, F. K., Nakayama, L. F., Melo, G. B., Stuchi, J. A., Lencione, D., Prado, P. V. D. S., Ribeiro, L. Z., Dib, S. A., & Regatieri, C. V. (2024) · Ophthalmology Science · doi:10.1016/j.xops.2024.100481 · Cited by 28
Applications of Deep Learning and Artificial Intelligence in Retina
Date, R. C., Jesudasen, S. J., & Weng, C. Y. (2018) · International Ophthalmology Clinics · doi:10.1097/iio.0000000000000246 · Cited by 28
Thomas, N. M., & Jerome, S. A. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-18403-9 · Cited by 28
Artificial Intelligence in Medical Imaging: From Theory to Clinical Practice
Morra, L., Delsanto, S., & Correale, L. (2019) · CRC Press eBooks · doi:10.1201/9780367229184 · Cited by 28
Transparency in Artificial Intelligence Reporting in Ophthalmology-A Scoping Review
Chen, D. K., Geevarghese, A., Lee, S., Plovnick, C., Elgin, C. Y., Zhou, R. W., Oermann, E. K., Aphinyonaphongs, Y., & Al‐Aswad, L. A. (2024) · Ophthalmology Science · doi:10.1016/j.xops.2024.100471 · Cited by 27
Application of Artificial Intelligence in Precision Medicine for Diabetic Macular Edema
Li, L., Zhang, W., Tu, X., Pang, J., Lai, I. F., Jin, C., Cheung, C. Y.-L., & Lin, H. (2023) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000583 · Cited by 27
Clinical Role of Smartphone Fundus Imaging in Diabetic Retinopathy and Other Neuro-retinal Diseases
Pujari, A., Saluja, G., Agarwal, D., Sinha, A., Ananya, P. R., Kumar, A., & Sharma, N. (2021) · Current Eye Research · doi:10.1080/02713683.2021.1958347 · Cited by 27
Molani, A., Pennati, F., Ravazzani, S., Scarpellini, A., Storti, F. M., Vegetali, G., Paganelli, C., & Aliverti, A. (2024) · Sensors · doi:10.3390/s24206682 · Cited by 27
Kozlakidis, Z., Muradyan, A., & Sargsyan, K. (2024) · Sustainable development goals series · doi:10.1007/978-3-031-62332-5 · Cited by 27
do Rio, J. M. N., Nderitu, P., Bergeles, C., Sivaprasad, S., Tan, G. S. W., & Raman, R. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11030614 · Cited by 26
Wang, T.-W., Luo, W.-T., Tu, Y.-K., Chou, Y.-B., & Wu, Y.-T. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-02223-8 · Cited by 26
Rajalakshmi, R., Pramodkumar, T. A., Naziyagulnaaz, A. S., Anjana, R. M., Raman, R., Suchetha, M., & Mohan, V. (2024) · Seminars in Ophthalmology · doi:10.1080/08820538.2024.2432902 · Cited by 26
Self-citationA deep transfer learning approach for identification of diabetic retinopathy using data augmentation
Devi, Y. S., & Kumar, S. P. (2022) · IAES International Journal of Artificial Intelligence · doi:10.11591/ijai.v11.i4.pp1287-1296 · Cited by 26
Ten simple rules for engaging with artificial intelligence in biomedicine
Malik, A., Patel, P., Ehsan, L., Guleria, S., Hartka, T., Adewole, S., & Syed, S. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1008531 · Cited by 26
Examining the ocular fundus in neurology
Rodenbeck, S. J., & Mackay, D. D. (2018) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000637 · Cited by 26
Penha, F. M., Priotto, B. M., Hennig, F., Przysiezny, B., Wiethorn, B. A., Orsi, J., Nagel, I. B. F., Wiggers, B., Stuchi, J. A., Lencione, D., et al. (2023) · International Journal of Retina and Vitreous · doi:10.1186/s40942-023-00477-6 · Cited by 25
Manifestations of xenophobia in AI systems
Tomašev, N., Maynard, J. L., & Gabriel, I. (2024) · AI & Society · doi:10.1007/s00146-024-01893-4 · Cited by 26
The impact of artificial intelligence in screening for diabetic retinopathy in India
Rajalakshmi, R. (2019) · Eye · doi:10.1038/s41433-019-0626-5 · Cited by 25
Self-citationHow-to guide for smartphone slit-lamp imaging
Akkara, J., & Kuriakose, A. (2019) · Kerala Journal of Ophthalmology · doi:10.4103/kjo.kjo_24_19 · Cited by 25
Kalavar, M., Al-khersan, H., Sridhar, J. S., Gorniak, R., Lakhani, P. C., Flanders, A. E., & Kuriyan, A. E. (2020) · International Ophthalmology Clinics · doi:10.1097/iio.0000000000000333 · Cited by 24
Brennan, P., McNeil, A. J., Jing, M., Awuah, A., Finlay, D., Blighe, K., McLaughlin, J. A., Wang, R., Moore, J. E., Nesbit, M. A., et al. (2019) · Microvascular Research · doi:10.1016/j.mvr.2019.103907 · Cited by 24
Mokhashi, N., Grachevskaya, J., Cheng, L., Yu, D., Lu, X., Zhang, Y., & Henderer, J. D. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821999370 · Cited by 23
Naz, H. U., Nijhawan, R., & Ahuja, N. J. (2024) · International Ophthalmology · doi:10.1007/s10792-024-02975-4 · Cited by 23
Upadhyaya, S., Rao, D. P., Kavitha, S., Ganeshrao, S. B., Negiloni, K., Bhandary, S., Savoy, F. M., & Venkatesh, R. (2024) · Ophthalmology Glaucoma · doi:10.1016/j.ogla.2024.09.002 · Cited by 23
Krishnamoorthy, S. G., Weifeng, Y., Luo, J., & Kadry, S. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.120408 · Cited by 23
Utility of teleconsultation in accessing eye care in a developing country during COVID-19 pandemic
Mansoor, H., Khan, S. A., Afghani, T., Assir, M. Z., Ali, M., & Khan, W. A. (2021) · PLOS ONE · doi:10.1371/journal.pone.0245343 · Cited by 22
Deepa, R., & Sivasamy, A. (2023) · AIP Advances · doi:10.1063/5.0172226 · Cited by 22
Microfluidic Immunosensor for Point-of-Care-Testing of Beta-2-Microglobulin in Tear
Maity, S., Ghosh, S., Bhuyan, T., Das, D., & Bandyopadhyay, D. (2020) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c00289 · Cited by 22
Smartphone-Based Diabetic Retinopathy Severity Classification Using Convolution Neural Networks
Sheikh, S., & Qidwai, U. A. (2020) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-55190-2_35 · Cited by 22
Review of smartphone funduscopy for diabetic retinopathy screening
Vaughan, N. (2023) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2023.10.006 · Cited by 22
D-CNN and Image Processing Based Approach for Diabetic Retinopathy Classification
Khan, A., Kulkarni, N., Kumar, A., & Kamat, A. (2021) · Advances in intelligent systems and computing · doi:10.1007/978-981-16-2008-9_27 · Cited by 22
Modern Approach to Diabetic Retinopathy Diagnostics
Kąpa, M., Koryciarz, I., Kustosik, N., Jurowski, P., & Pniakowska, Z. (2024) · Diagnostics · doi:10.3390/diagnostics14171846 · Cited by 21
Teoh, C. S., Wong, K. H., Xiao, D., Wong, H. C., Zhao, P., Chan, H. W., Yuen, Y. S., Naing, T., Kanagasingam, Y., & Koh, V. (2023) · Healthcare · doi:10.3390/healthcare11121697 · Cited by 21
Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
Otero, C., García‐Porta, N., Tabernero, J., & Pardhan, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-37925-5 · Cited by 21
Using MobileNetV2 to Classify the Severity of Diabetic Retinopathy
Sheikh, S., & Qidwai, U. A. (2020) · International Journal of Simulation Systems Science & Technology · doi:10.5013/ijssst.a.21.02.16 · Cited by 21
Hasan, S. U., & Siddiqui, M. A. R. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110943 · Cited by 20
Detection of retinal abnormalities using smartphone-captured fundus images: a survey
Akil, M., & Elloumi, Y. (2019) · Real-Time Image Processing and Deep Learning · doi:10.1117/12.2519094 · Cited by 20
Tan, C. H., Quah, W.-H., Tan, C. S., Smith, H. E., & Car, L. T. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-028811 · Cited by 19
Reducing the Cost of Diabetes Care with Telemedicine, Smartphone, and Home Monitoring
Kesavadev, J., & Mohan, V. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-023-00363-y · Cited by 19
Self-citationSheikh, A., Bhatti, A., Adeyemi, O. J., Raja, M., & Sheikh, I. (2021) · Journal of Current Ophthalmology · doi:10.4103/2452-2325.329064 · Cited by 19
Sivaprasad, S., Netuveli, G., Wittenberg, R., Khobragade, R. N., Sadanandan, R., Gopal, B. K., Premnazir, L., Conroy, D. M., Srinath, J., Ramakrishnan, R., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-040577 · Cited by 19
Diabetic retinopathy detection using EADBSC and improved dilated ensemble CNN-based classification
Thomas, N. M., & Jerome, S. A. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-16923-4 · Cited by 19
Chandhakanond, P., & Aimmanee, P. (2025) · Scientific Reports · doi:10.1038/s41598-025-90048-6 · Cited by 19
Deep learning-based classification of multiple fundus diseases using ultra-widefield images
Duan, M.-M., & Tu, X. (2025) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2025.1630667 · Cited by 19
Teaching Smartphone Funduscopy with 20 Diopter Lens in Undergraduate Medical Education
Kohler, J., Tran, T. M., Sun, S. Y., & Montezuma, S. R. (2021) · Clinical ophthalmology · doi:10.2147/opth.s266123 · Cited by 19
Moannaei, M., Jadidian, F., Doustmohammadi, T., Kiapasha, A. M., Bayani, R., Rahmani, M., Jahanbazy, M. R., Sohrabivafa, F., Asadi Anar, M., Magsudy, A., et al. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01336-1 · Cited by 18
Retinal Vascular Imaging in Vascular Cognitive Impairment: Current and Future Perspectives
Dumitrașcu, O., & Qureshi, T. A. (2018) · Journal of Experimental Neuroscience · doi:10.1177/1179069518801291 · Cited by 18
Dunn, H., Marks, S., Teo, K. Z., Dunn, S. M., Healey, P. R., & White, A. J. R. (2021) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.13977 · Cited by 18
A deep learning-based ADRPPA algorithm for the prediction of diabetic retinopathy progression
Wang, V. Y., Lo, M., Chen, T., Huang, C.-H., Huang, A., & Wang, P. (2024) · Scientific Reports · doi:10.1038/s41598-024-82884-9 · Cited by 18
Cougnard‐Grégoire, A., Korobelnik, J., Delyfer, M., Rigalleau, V., Daïen, V., Creuzot-Garcher, C. P., & Delcourt, C. (2020) · Ophthalmic Research · doi:10.1159/000506136 · Cited by 18
Progress of Imaging in Diabetic Retinopathy—From the Past to the Present
Horie, S., & Ohno‐Matsui, K. (2022) · Diagnostics · doi:10.3390/diagnostics12071684 · Cited by 18
Chen, K.-Y., Chan, H.-C., & Chan, C.-M. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02627-0 · Cited by 17
Paterson, E. N., Cardwell, C., MacGillivray, T. J., Trucco, E., Doney, A. S., Foster, P., Maxwell, A. P., McKay, G. J., on behalf of The UK Biobank Eye and Vision Consortium, Aslam, T., et al. (2021) · BMC Nephrology · doi:10.1186/s12882-021-02273-6 · Cited by 17
Computational intelligence in eye disease diagnosis: a comparative study
Kumar, S. V. M., & Gunasundari, R. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02737-3 · Cited by 17
Prayogo, M. E., Zaharo, A. F., Damayanti, N. N. R., Widyaputri, F., Thobari, J. A., Susanti, V. Y., & Sasongko, M. B. (2023) · Clinical ophthalmology · doi:10.2147/opth.s416422 · Cited by 17
Optimized Feature Selection Approach for Smartphone Based Diabetic Retinopathy Detection
Gupta, S., Thakur, S., & Gupta, A. (2022) · International Conference on Innovative Practices in Technology and Management (ICIPTM) · doi:10.1109/iciptm54933.2022.9754021 · Cited by 17
Learning curve evaluation upskilling retinal imaging using smartphones
Jansen, L. G., Shah, P. N., Wabbels, B., Holz, F. G., Finger, R. P., & Wintergerst, M. W. M. (2021) · Scientific Reports · doi:10.1038/s41598-021-92232-w · Cited by 17
Diabetic Retinopathy Detection-MobileNet Binary Classifier
Pavate, A. A., Mistry, J., Palve, R., & Gami, N. (2020) · Acta Scientific Medical Sciences · doi:10.31080/asms.2020.04.0800 · Cited by 17
Bhatt, J., Jain, S., & Bhatia, D. D. (2025) · Sensors & Diagnostics · doi:10.1039/d5sd00146c · Cited by 16
Prevalence and risk factors for diabetic retinopathy in prediabetes in Asian Indians
Rajalakshmi, R., UmaSankari, G., Sivaprasad, S., Venkatesan, U., Kumpatla, S., Shanthirani, C. S., Viswanathan, V., & Mohan, V. (2022) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2022.108131 · Cited by 16
Self-citationSeipetdenova, S., Oladejo, T. O., Bekmurzayeva, A., Tan, C., Yang, M., Blanc, W., & Tosi, D. (2025) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2025.108943 · Cited by 16
Smartphone Ophthalmoscopy: is there a place for it?
Pujari, A. (2021) · Clinical ophthalmology · doi:10.2147/opth.s243103 · Cited by 16
Fractal Dimension-Based Infection Detection in Chest X-ray Images
Ghatak, S., Chakraborti, S., Gupta, M., Dutta, S., Pati, S. K., & Bhattacharya, A. (2022) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-022-04108-y · Cited by 16
Leveraging Large Language Models to Generate Multiple-Choice Questions for Ophthalmology Education
Gholami, S., Mummert, D. B., Wilson, B., Page, S., Dodhia, R. M., Ferres, J. L., Weeks, W. B., Fajardo, D. E., & Bojikian, K. D. (2025) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2025.3622 · Cited by 15
Smartphone-basierte Fundusfotografie: Anwendungen und Adapter
Jansen, L. G., Schultz, T., Holz, F. G., Finger, R. P., & Wintergerst, M. W. M. (2021) · Der Ophthalmologe · doi:10.1007/s00347-021-01536-9 · Cited by 15
Liu, R., Li, H., Liang, F., Yao, L., Liu, J., Li, M., Cao, L., & Song, B. (2019) · Medicine · doi:10.1097/md.0000000000016227 · Cited by 15
Alshammari, R. D., Haliqa, W. A., & Majzoub, R. Y. (2025) · Journal of Medical Imaging and Interventional Radiology · doi:10.1007/s44326-025-00083-w · Cited by 14
Advanced Artificial Intelligence Technologies Transforming Contemporary Pharmaceutical Research
Kumar, P., Chaudhary, B., Arya, P., Chauhan, R., Devi, S., Parejiya, P. B., & Gupta, M. M. (2025) · Bioengineering · doi:10.3390/bioengineering12040363 · Cited by 14
Automated detection of diabetic retinopathy using optimized convolutional neural network
Minija, S. J., Rejula, M. A., & Ross, B. S. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-16204-0 · Cited by 14
Automated Early Diabetic Retinopathy Detection Using a Deep Hybrid Model
Shazia, A., Dahri, F. H., Ali, A., Adnan, M., Laghari, A. A., & Nawaz, T. (2024) · ICCK Transactions on Emerging Topics in Artificial Intelligence · doi:10.62762/tetai.2024.305743 · Cited by 14
Rani, P. K., Peguda, H. K., Chandrashekher, M., Swarna, S., Jonnadula, G. B., James, J., Shinde, L., & Bharadwaj, S. R. (2021) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1944_20 · Cited by 14
Wang, T., Luo, W.-T., Tu, Y., Chou, Y.-B., & Wu, Y. (2025) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2025.11.012 · Cited by 14
Horie, S., Kukimoto, N., Kamoi, K., Igarashi-Yokoi, T., Yoshida, T., & Ohno‐Matsui, K. (2021) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000432 · Cited by 14
Artificial Intelligence: The Gateway to Better Medical Diagnosis
Hameed, E. K., & Al-Ameri, L. T. (2024) · AL-Kindy College Medical Journal · doi:10.47723/w1ymg293 · Cited by 14
A Machine Learning Approach to Detect Diabetic Retinopathy Using Convolutional Neural Network
Chowdhury, M. M. H., Meem, N. T. A., & Marium-E-Jannat (2019) · Algorithms for intelligent systems · doi:10.1007/978-981-13-7564-4_23 · Cited by 14
Metadata
- Authors
- Rajalakshmi, R., Subashini, R., Anjana, R. M., & Mohan, V.
- Affiliations
- Madras Diabetes Research Foundation (IN)
- Corresponding author
- Rajalakshmi, Ramachandran
- Venue
- Eye
- Published
- 2018-03-09
- Volume
- 32
- Issue
- 6
- Pages
- 1138-1144
- ISSN
- 0078-5334 (ISSN-L)
- 0950-222X
- 1476-5454
- PMC
- PMC5997766
- OpenAlex
- W2789360655
- Cited by
- 462
- References
- 23
- Citations by year
- 2026: 46 · 2025: 64 · 2024: 68 · 2023: 72 · 2022: 48 · 2021: 63 · 2020: 65 · 2019: 24 · 2018: 12
- FWCI
- 28.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- Locations
- Eye (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Keywords
- diabetic retinopathy, automated retinopathy detection, artificial intelligence, type 2 diabetes, diabetic macular edema, referable diabetic retinopathy, retinal screening, diagnostic accuracy, mass screening
- MeSH terms
- Smartphone, Adult, Diabetic Retinopathy, Diagnosis, Computer-Assisted, Female, Humans, Male, Middle Aged, Photography, Predictive Value of Tests, Retina, Sensitivity and Specificity, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.