Autonomous Artificial Intelligence in Diabetic Retinopathy Testing—Lessons Learned on Successful Health System Adoption
Open accessAbstract
Purpose: Artificial intelligence (AI)-aided diabetic retinopathy (DR) testing systems have been commercialized for 5 years, but adoption is still relatively limited. This article aims to summarize the evidence in clinical settings, describe the current state of adoption, and share themes of successful implementation. Design: Evaluation of diagnostic test or technology. Participants: Ophthalmologists. Methods: We performed literature review and conducted interviews with ophthalmologists leading implementation of AI-aided DR testing programs at several academic health systems. The study focused on the 3 currently US Food and Drug Administration-cleared AI systems: LumineticsCore, EyeArt, and AEYE Diagnostic Screening (AEYE-DS), assessing their performance and strategies utilized by health systems to effectively implement this technology in clinics. Main Outcome Measures: Diagnostic accuracy data, ophthalmologist feedback. Results: The literature review found 6 publications reporting diagnostic accuracy data of autonomous AI DR testing in primary care office settings, including 5 for LumineticsCore and 1 for EyeArt. Additional articles, of which 18 were selected for detailed review, addressed impact on patient adherence, health equity, and carbon footprint, as well as cost-effectiveness and workflow efficiency analyses. There were no studies comparing the systems on the same patients. In aggregate, adopters of the AI systems reported average nonmydriatic gradability of 49% to 75% (n = 5), sensitivity 87% to 100% (n = 3), and specificity 60% to 91% (n = 4). Based on public records at the time of writing, both LumineticsCore and EyeArt have >5 academic adopters in the United States. Limited information is available on AEYE-DS given recency of regulatory clearance. Elements of successful implementation include proper site selection, aligning AI tools with primary care clinic workflows, streamlining patient engagement and referrals, and ongoing training of staff. Health systems utilizing AI reported improved Healthcare Effectiveness Data and Information Set measures, health equity, productivity, and patient adherence to follow-up with ophthalmology. Conclusions: Artificial intelligence-aided diabetic eye examinations present a promising solution to facilitate early detection of DR, promote equitable access, and drive down system-level cost of care. Its successful implementation requires addressing technological, operational, and stakeholder engagement challenges. Our study underscores the potential of AI to revolutionize care delivery provided its adoption is strategically managed. Financial Disclosures: The author has no/the authors have no proprietary or commercial interest in any materials discussed in this article.
AI snapshot
Written from the paper’s full text.
TL;DR
This review and expert-interview study summarizes evidence and adoption lessons for the three US FDA-cleared autonomous AI diabetic retinopathy testing systems: LumineticsCore, EyeArt, and AEYE-DS. It reports variable real-world gradability and accuracy, limited comparative data, and identifies top-down stakeholder alignment, workflow redesign, site selection, and performance tracking as keys to successful health system adoption.
Key findings
- The literature review found 6 publications reporting diagnostic accuracy of autonomous AI DR testing in primary care office settings, including 5 for LumineticsCore and 1 for EyeArt; there were no studies comparing the systems on the same patients.
- In aggregate, adopters reported average nonmydriatic gradability of 49% to 75% (n = 5), sensitivity 87% to 100% (n = 3), and specificity 60% to 91% (n = 4).
- Based on public records at the time of writing, both LumineticsCore and EyeArt had >5 academic adopters in the United States, while limited information was available on AEYE-DS given the recency of its regulatory clearance.
- Elements of successful implementation included proper site selection, aligning AI tools with primary care clinic workflows, streamlining patient engagement and referrals, and ongoing staff training; health systems using AI reported improved HEDIS measures, health equity, productivity, and patient adherence to follow-up with ophthalmology.
Methods
- Systematic literature search across PubMed, Google Scholars, Scopus, and Web of Science from January 2010 to October 2023 using keywords such as “artificial intelligence diabetic retinopathy evidence,” “autonomous eye exam,” “idx-dr,” “eyeart,” and “aeye-ds”; initial search yielded 106 articles, duplicates were removed, two independent reviewers screened titles/abstracts and full texts, and 18 articles were selected for detailed analysis.
- Semistructured interviews with 6 ophthalmologists leading implementation of AI DR testing programs at academic health systems; interviews lasted approximately 60 minutes, covered experience, implementation learnings/challenges, practice impact, and patient experience, were recorded and transcribed, and were analyzed thematically.
- The study focused on the 3 currently FDA-cleared AI systems—LumineticsCore, EyeArt, and AEYE-DS—assessing diagnostic accuracy data and ophthalmologist feedback.
Limitations
- The paper states that there were no studies comparing the systems on the same patients, that limited information is available on AEYE-DS given recency of regulatory clearance, that the predictive dilation model has not been proven prospectively, and that there has been limited data to prove the observation that referrals are more likely to be disease-positive without change in overall volume after AI rollout.
- Evident from the text: adoption data rely on publicly available information such as press releases and academic publications, and the adopter table is described as nonexhaustive.
- Evident from the text: the expert interviews involved only 6 ophthalmologists at academic health systems, and the literature search ended in October 2023, so findings may not generalize to all practice settings or capture newer evidence.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
32 of 69 cited sources checked · 3 supported · 0 flagged · accuracy not yet measured
- Premisecitation
Initial adoption of AI-aided testing systems is often limited by challenges including lack of trust, resistance to change, training gaps, and uncertainty of the cost-benefit.
“While AI-aided testing systems hold promise for helping drive down the social and economic burden of DR, initial adoption of new technology is often limited by many challenges including lack of trust, resistance to change, training gaps, and uncertainty of the cost-benefit.9”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [9] Lluch M. Healthcare professionals' organisational barriers to health information technologies-a literature review Int J Med Inform 80 2011 849 862 22000677 source
The Results section on adaptive optics imaging describes barriers to that modality’s widespread use—time-intensive analysis, limited device availability, and lack of standardization—not barriers to adopting AI-aided testing. Searches for AI adoption, trust, resistance to change, training, and cost-benefit found no passage addressing the claimed challenges; page numbers were unavailable in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Interpretationcitation
The 2016 Abramoff et al study was limited by its retrospective nature and therefore could not demonstrate the system's clinical potential.
“However, this study remained limited given its retrospective nature and therefore could not demonstrate the system’s clinical potential.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [14] Abràmoff M.D. Lou Y. Erginay A. Improved automated detection of diabetic retinopathy on a publicly available dataset through integration of deep learning Invest Ophthalmol Vis Sci 57 2016 5200 5206 27701631 source
The Introduction discusses an autonomous diabetic retinal-exam product and its CPT code, but does not discuss a 2016 Abramoff study. Searches for the study’s retrospective design and its ability to demonstrate clinical potential found no passage addressing either point. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Two years after IDx-DR, EyeArt received 510(k) clearance on the LumineticsCore predicate for detecting more-than-mild DR and vision-threatening DR.
“Two years later, another AI system, EyeArt (Eyenuk Inc), received 510(k) clearance on the LumineticsCore predicate for detecting more-than-mild DR (mtmDR) and vision-threatening DR.3”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [3] Anon Eyenuk announces FDA clearance for EyeArt autonomous AI system for diabetic retinopathy screening https://www.businesswire.com/news/home/20200805005495/en/Eyenuk-Announces-FDA-Clearance-EyeArt-Autonomous-AI 2020 source
The Retinopathy > Clinical Features passages discuss diabetic retinopathy and its treatment, not AI screening systems or regulatory clearance (page unavailable). Searches for EyeArt, LumineticsCore, 510(k), and automated screening found no passage in our copy addressing the claimed clearance or its timing. (LLM, conf=0.78)
Experimental — accuracy not yet measured
- Premisecitation
In a 2016 study by Abramoff et al, an earlier version of LumineticsCore reported a referable DR sensitivity of 96.8% and specificity of 87.0% against the Messidor-2 database.
“In a study by Abramoff et al in 2016, an earlier version of LumineticsCore reported a referable DR sensitivity of 96.8% and specificity of 87.0% against the Messidor-2 database.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [14] Abràmoff M.D. Lou Y. Erginay A. Improved automated detection of diabetic retinopathy on a publicly available dataset through integration of deep learning Invest Ophthalmol Vis Sci 57 2016 5200 5206 27701631 source
The Introduction discusses an autonomous diabetic retinal exam product, and Current context mentions the IDx-DR device, but neither reports a 2016 study or diagnostic performance. Searches for the stated sensitivity, specificity, Messidor-2, and the 2016 Abramoff study found no passage addressing those results. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Prior to autonomous AI testing, all patients were referred to ophthalmology for an annual eye examination.
“Prior to autonomous AI testing, all patients were referred to ophthalmology for an annual eye examination.59”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [59] American Diabetes Association Professional Practice Committee 12. Retinopathy, neuropathy, and foot care: standards of medical care in Diabetes-2022 Diabetes Care 45 2022 S185 S194 34964887 source
Section 12.3 recommends eye examinations that are generally repeated annually and permits examination by an ophthalmologist or optometrist. It does not establish that, before autonomous AI testing, all patients were referred to ophthalmology for annual examinations; it also allows 1–2-year screening intervals for some patients. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Premisecitation
In September 2020, the American Medical Association CPT Editorial Panel created code 92229 for retinal imaging with autonomous point-of-care interpretation, allowing institutions adopting AI-guided DR testing to bill for the procedure.
“Earlier in September 2020, the American Medical Association Current Procedural Terminology (CPT) Editorial Panel created code 92229 for retinal imaging with autonomous point-of-care interpretation, which allowed institutions that chose to adopt AI-guided DR testing to be billed for the procedure.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [19] Anon AMA releases 2021 CPT code set. American Medical Association https://www.ama-assn.org/press-center/press-releases/ama-releases-2021-cpt-code-set source
The Background and Retina fundus imaging modalities sections discuss AI-based diabetic retinopathy screening and FDA approval, but do not address CPT code 92229 or billing. Searches for the code, autonomous point-of-care interpretation, and AMA/CPT reimbursement found no passage supporting the September 2020 claim. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Interpretationcitation
These findings, along with EyeArt's use in the European Union and Canada, bolstered the credibility that EyeArt could be a clinically utilized AI-guided DR testing program in the United States.
“These findings, along with its use in the European Union and Canada, bolstered the credibility that EyeArt could be a clinically utilized AI-guided DR testing program in the United States.34”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [34] Bhaskaranand M. Ramachandra C. Bhat S. The value of automated diabetic retinopathy screening with the EyeArt system: a study of more than 100,000 consecutive encounters from people with diabetes Diabetes Technol Ther 21 2019 635 643 31335200 PMC6812728 source
The Introduction and Conclusion discuss AI-based diabetic-retinopathy screening and commercial systems generally, but do not identify EyeArt. Searches for EyeArt, its use in the European Union and Canada, and its potential clinical use in the United States found no passage addressing those claims. (LLM, conf=0.74)
Experimental — accuracy not yet measured
- Premisecitation
Johns Hopkins University found that the percentage of diabetes patients who received annual eye examinations increased from 46.4% in nontesting clinics to 64% in AI-testing clinics in 2021.
“Johns Hopkins University found the percentage of diabetes patients who received annual eye examinations increased from 46.4% in nontesting clinics to 64% in AI-testing clinics in 2021.48”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [48] Huang J. Wang J. Channa R. Autonomous artificial intelligence exams are associated with higher adherence to diabetic retinopathy testing in an integrated healthcare system Invest Ophthalmol Vis Sci 64 2023 212 source
The Introduction (page unavailable) discusses AI-based diabetic retinopathy screening generally, but does not report annual eye-examination rates. Searches for 46.4%, 64%, Johns Hopkins University, and clinic-level screening uptake found no passage in our copy addressing the claimed 2021 comparison. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
Based on a 2023 claims database, DR testing has become one of the most widely adopted and fastest-growing AI-aided medical procedures in the United States, second only to coronary artery disease.
“Based on the claims database in 2023, DR testing has become one of the most widely adopted and fastest-growing AI-aided medical procedures in the United States, only second to coronary artery disease.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [21] Wu K. Wu E. Theodorou B. Characterizing the clinical adoption of medical AI devices through U.S. insurance claims. NEJM AI https://ai.nejm.org/doi/full/10.1056/AIoa2300030 2023 source
The Introduction says adoption of AI-based DR screening had been slow, and the Discussion reports EyeArt’s screening performance rather than procedure uptake. Our copy contains no 2023 claims-database analysis, U.S. adoption or growth ranking, or comparison with coronary artery disease; a 2019 observation does not establish the 2023 claim. (LLM, conf=0.78)
Experimental — accuracy not yet measured
- Premisecitation
Liu et al found that among 180 study participants who underwent nonmydriatic fundus photography followed by automated retinal image analysis with human supervision, those referred for follow-up ophthalmic evaluation had an adherence rate of 55.4% at 1 year, compared with the historical adherence rate of 18.7%.
“Liu et al39 found that among 180 study participants who underwent nonmydriatic fundus photography followed by automated retinal image analysis with human supervision, those referred for follow-up ophthalmic evaluation had an adherence rate of 55.4% at 1 year, compared with the historical adherence rate of 18.7%.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [39] Liu J. Gibson E. Ramchal S. Diabetic retinopathy screening with automated retinal image analysis in a primary care setting improves adherence to ophthalmic care Ophthalmol Retina 5 2021 71 77 32562885 PMC8546907 source
Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
- Premisecitation
Stanford University found that those referred after an AI-based examination followed up at the eye institute at a rate nearly 3 times higher than those referred after teleophthalmology-only testing.
“In the same study as previously mentioned, Stanford University found that those referred after an AI-based examination followed up at the eye institute at a rate nearly 3 times higher than those referred after teleophthalmology-only testing.42”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [42] Fuller S.D. Hu J. Liu J.C. Five-year cost-effectiveness modeling of primary care-based, nonmydriatic automated retinal image analysis screening among low-income patients with diabetes J Diabetes Sci Technol 16 2022 415 427 33124449 PMC8861785 source
Section 12.3 discusses AI-based retinal screening and follow-up after abnormal results, but it does not report a Stanford study or compare follow-up rates after AI-based and teleophthalmology-only examinations. Searches for the claimed study and the nearly threefold follow-up difference found no matching passage in our copy. (LLM, conf=0.75)
Experimental — accuracy not yet measured
- Premisecitation
In randomized clinical trials, LumineticsCore has shown to improve physician productivity.
“In randomized clinical trials, this system has shown to improve health equity in minorities26 and physician productivity,8 as well as demonstrated safety, efficacy, and equity in youth with diabetes.7”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [8] Abramoff M.D. Whitestone N. Patnaik J.L. Autonomous artificial intelligence increases real-world specialist clinic productivity in a cluster-randomized trial npj Digital Med 6 2023 1 8 PMC10550906 37794054 source
The available passages contain only the article title and publication information (pp. A419–A420), not study findings. Searches for LumineticsCore, randomized trials, and physician productivity returned no passage addressing the attributed claim. (LLM, conf=0.72)
Experimental — accuracy not yet measured
- Premisecitation
Code 92229 was the first CPT code for autonomous AI in any specialty.
“This was the first CPT code for autonomous AI in any specialty.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [20] Frank R.A. Jarrin R. Pritzker J. Developing current procedural terminology codes that describe the work performed by machines NPJ digital Med 5 2022 177 PMC9719561 36463327 source
The Methods describe automated diabetic-retinopathy analysis, and the Discussion discusses its use with smartphone imaging, but neither addresses CPT coding. Searches for “92229,” “CPT,” and reimbursement found no passage supporting the claim that this was the first CPT code for autonomous AI in any specialty. (LLM, conf=0.76)
Experimental — accuracy not yet measured
- Premisecitation
A pivotal retrospective study from 2019 performed by Eyenuk with >100,000 patients tested by the software demonstrated a 91.3% sensitivity and 91.1% specificity.
“A pivotal retrospective study from 2019 performed by Eyenuk with >100 000 patients tested by the software demonstrated a 91.3% sensitivity and 91.1% specificity.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [34] Bhaskaranand M. Ramachandra C. Bhat S. The value of automated diabetic retinopathy screening with the EyeArt system: a study of more than 100,000 consecutive encounters from people with diabetes Diabetes Technol Ther 21 2019 635 643 31335200 PMC6812728 source
The Automated detection and classification section reports performance figures for other diabetic-retinopathy algorithms, including a 91.1% specificity for Ting et al.’s model. Searches of our copy for Eyenuk, EyeArt, the claimed study size, and 91.3% sensitivity found no passage describing the attributed 2019 retrospective study or its results; no page number is available in our copy. (LLM, conf=0.74)
Experimental — accuracy not yet measured
- Premisecitation
Combining both AI and human interpretation into a hybrid workflow improved testing sensitivity to 95.5% and specificity to 98.2%.
“Combining both the AI and human interpretation into a hybrid workflow as described earlier, this group found improvement of testing sensitivity to 95.5% and specificity to 98.2%.48”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [48] Huang J. Wang J. Channa R. Autonomous artificial intelligence exams are associated with higher adherence to diabetic retinopathy testing in an integrated healthcare system Invest Ophthalmol Vis Sci 64 2023 212 source
The Automated detection and classification section reports performance figures for automated models, but not a hybrid AI–human workflow with 95.5% sensitivity and 98.2% specificity. Searches for both figures and for combined human–AI interpretation found no passage in our copy reporting the claimed result. (LLM, conf=0.72)
Experimental — accuracy not yet measured
- Premisecitation
Similar cost-effectiveness of autonomous AI testing has been demonstrated in Europe.
“Similar cost-effectiveness has been demonstrated in Europe.64”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [64] Tufail A. Rudisill C. Egan C. Automated diabetic retinopathy image assessment software: diagnostic accuracy and cost-effectiveness compared with human graders Ophthalmology 124 2017 343 351 28024825 source
The Health Economic Analysis evaluates automated diabetic-retinopathy screening in the UK, and the Results report lower costs than manual grading. But the Results also find that both systems were less likely to classify disease correctly; the paper does not establish unqualified cost-effectiveness. (LLM, conf=0.85)
Experimental — accuracy not yet measured
- Findingown data
In aggregate, adopters of the AI systems reported sensitivity of 87% to 100% (n = 3).
“In aggregate, adopters of the AI systems reported average nonmydriatic gradability of 49% to 75% (n = 5), sensitivity 87% to 100% (n = 3), and specificity 60% to 91% (n = 4).”
Quote in the paperSubstantial claim - Findingown data
In aggregate, adopters of the AI systems reported average nonmydriatic gradability of 49% to 75% (n = 5).
“In aggregate, adopters of the AI systems reported average nonmydriatic gradability of 49% to 75% (n = 5), sensitivity 87% to 100% (n = 3), and specificity 60% to 91% (n = 4).”
Quote in the paperNot a substantial claim - Findingnone given
There were no studies comparing the AI systems on the same patients.
“There were no studies comparing the systems on the same patients.”
Quote in the paperNot a substantial claim - Findingown data
In aggregate, adopters of the AI systems reported specificity of 60% to 91% (n = 4).
“In aggregate, adopters of the AI systems reported average nonmydriatic gradability of 49% to 75% (n = 5), sensitivity 87% to 100% (n = 3), and specificity 60% to 91% (n = 4).”
Quote in the paperNot a substantial claim - Findingown data
Health systems utilizing AI reported improved health equity.
“Health systems utilizing AI reported improved Healthcare Effectiveness Data and Information Set measures, health equity, productivity, and patient adherence to follow-up with ophthalmology.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Findingnone given
Health systems utilizing AI reported improved Healthcare Effectiveness Data and Information Set measures.
“Health systems utilizing AI reported improved Healthcare Effectiveness Data and Information Set measures, health equity, productivity, and patient adherence to follow-up with ophthalmology.”
Quote in the paperNot a substantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Findingnone given
Health systems utilizing AI reported improved productivity.
“Health systems utilizing AI reported improved Healthcare Effectiveness Data and Information Set measures, health equity, productivity, and patient adherence to follow-up with ophthalmology.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Findingnone given
Health systems utilizing AI reported improved patient adherence to follow-up with ophthalmology.
“Health systems utilizing AI reported improved Healthcare Effectiveness Data and Information Set measures, health equity, productivity, and patient adherence to follow-up with ophthalmology.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Findingown data
Adopters have found various levels of challenges in stakeholder alignment, largely depending on the historic interdepartmental relationship.
“Adopters have found various levels of challenges in stakeholder alignment, largely depending on the historic interdepartmental relationship.”
Quote in the paperSubstantial claim- Rests on an assumption: The 6 academic ophthalmology programs interviewed are representative of health systems adopting autonomous AI testing, so their experiences can be generalized.
- Findingown data
Based on interviews with 6 academic ophthalmology programs, buy-in from the primary care team is critical for initiating utilization of AI examinations.
“Based on our interviews, the 6 academic ophthalmology programs agreed that buy-in from the primary care team is critical for initiating utilization of AI examinations.”
Quote in the paperSubstantial claim - Findingnone given
The level of receptiveness to autonomous AI testing varies from site to site depending on the preceding resource and culture.
“A key observation here is that the level of receptiveness varies from site to site depending on the preceding resource and culture.”
Quote in the paperSubstantial claim - Findingnone given
Among the early adopters, 2 that started with a pilot increased the number of clinics using AI testing by 50% to 100% over a 2-year period despite the impact of coronavirus disease.
“Among the early adopters, 2 that started with a pilot have increased the number of clinics using AI testing by 50% to 100% over a 2-year period despite the impact of coronavirus disease.”
Quote in the paperNot a substantial claim - Findingown data
Among the adopters interviewed, the majority launched the autonomous AI program through a pilot in 4 to 6 primary care sites out of the 30+ locations in their university health network.
“Among the adopters we interviewed with, the majority launched the autonomous AI program through a pilot in 4 to 6 primary care sites out of the 30+ locations in their university health network.”
Quote in the paperNot a substantial claim - Findingnone given
Academic health systems have been the earliest adopters of autonomous AI testing.
“Academic health systems have been the earliest adopters of autonomous AI testing.”
Quote in the paperNot a substantial claim- Rests on an assumption: Today, LumineticsCore is utilized in >1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.
- Rests on an assumption: To date, EyeArt has been utilized in the United States by institutions such as Temple Health, University of Utah Health, and Cedars Sinai Health System.
- Rests on an assumption: To our best knowledge, AEYE-DS has been implemented in select community-based health organizations in the United States, such as the Bethesda Health Clinic.
- Findingnone given
There are 2 main archetypes of adopters: those that had an existing human-read DR testing program in place at the time of introducing AI and those that did not.
“There are 2 main archetypes of adopters, those that had an existing human-read DR testing program in place at the time of introducing AI and those that did not.”
Quote in the paperNot a substantial claim - Findingown data
Based on interviews, the most success with implementation of AI-aided DR detection is observed when it is driven from top-down at the health system leadership level.
“Based on our interviews, we have observed the most success with implementation of AI-aided DR detection when it is driven from top-down at the health system leadership level.”
Quote in the paperSubstantial claim- Rests on an assumption: The 6 academic ophthalmology programs interviewed are representative of health systems adopting autonomous AI testing, so their experiences can be generalized.
- Findingown data
In practice, the nonmydriatic gradability is found to range from 49% to 75%.
“In practice, the nonmydriatic gradability is found to range from 49% to 75% (Table 1).”
Quote in the paperNot a substantial claim - Findingown data
Mayo Clinic successfully implemented reflex dilation at a single site.
“Mayo Clinic successfully implemented reflex dilation at a single site and did the following: when a patient receives an ungradable result, the technician sends an order for the patient to receive dilating eye drops from a registered nurse.”
Quote in the paperNot a substantial claim - Findingnone given
Connecting the local information technology team with the vendor information technology team was found to be helpful.
“Connecting the local information technology team with the vendor information technology team was also found to be helpful.”
Quote in the paperNot a substantial claim - Interpretationreasoning
The 2018 pivotal study played a role in informing the FDA's decision to clear IDx-DR.
“and played a role in informing the FDA's decision to clear IDx-DR.”
Quote in the paperSubstantial claim - Premisecitation
In 2018, the US FDA granted De Novo authorization to IDx-DR (now LumineticsCore) as the first autonomous AI-based diagnostic system for diabetic retinopathy testing.
“In 2018, the US Food and Drug Administration (FDA) granted De Novo authorization to IDx-DR (now rebranded as LumineticsCore) (Digital Diagnostics Inc) as the first autonomous AI-based diagnostic system for diabetic retinopathy (DR) testing,2”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [2] Office of the Commissioner FDA permits marketing of artificial intelligence-based device to detect certain diabetes-related eye problems. US Food and Drug Administration https://www.fda.gov/news-events/press-announcements/fda-permits-marketing-artificial-intelligence-based-device-detect-certain-diabetes-related-eye 2020 source
- Premisecitation
IDx-DR received the first ever FDA clearance for an autonomous AI algorithm.
“and the first ever FDA clearance for an autonomous AI algorithm.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [2] Office of the Commissioner FDA permits marketing of artificial intelligence-based device to detect certain diabetes-related eye problems. US Food and Drug Administration https://www.fda.gov/news-events/press-announcements/fda-permits-marketing-artificial-intelligence-based-device-detect-certain-diabetes-related-eye 2020 source
- Premisereasoning
The statistics in the 2018 Abramoff et al trial were calculated against a prognostic level 1 reference standard, meaning performance was compared against diagnostic modalities that include OCT imaging for central-involved diabetic macular edema rather than against clinicians.
“Of note, the statistics are calculated against a prognostic level 1 reference standard, meaning that rather than compare the performance against clinicians, it was compared against diagnostic modalities that include OCT imaging for central-involved diabetic macular edema.”
Quote in the paperNot a substantial claim - Interpretationnone given
Streamlining patient engagement and referrals is an element of successful implementation of AI-aided DR testing.
“Elements of successful implementation include proper site selection, aligning AI tools with primary care clinic workflows, streamlining patient engagement and referrals, and ongoing training of staff.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Premisecitation
In April 2018, the US FDA cleared the first generation of IDx-DR through the De Novo premarket review pathway as a class II medical device.
“In April 2018, the US FDA cleared the first generation of IDx-DR through the De Novo premarket review pathway as a class II medical device.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [2] Office of the Commissioner FDA permits marketing of artificial intelligence-based device to detect certain diabetes-related eye problems. US Food and Drug Administration https://www.fda.gov/news-events/press-announcements/fda-permits-marketing-artificial-intelligence-based-device-detect-certain-diabetes-related-eye 2020 source
- Interpretationreasoning
The 2018 pivotal study illuminated the feasibility of implementing AI in clinical spaces.
“This pivotal study illuminated the feasibility of implementing AI in clinical spaces”
Quote in the paperSubstantial claim - Interpretationnone given
Proper site selection is an element of successful implementation of AI-aided DR testing.
“Elements of successful implementation include proper site selection, aligning AI tools with primary care clinic workflows, streamlining patient engagement and referrals, and ongoing training of staff.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Interpretationreasoning
AI-aided diabetic eye examinations present a promising solution to drive down system-level cost of care.
“Artificial intelligence–aided diabetic eye examinations present a promising solution to facilitate early detection of DR, promote equitable access, and drive down system-level cost of care.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Interpretationnone given
Aligning AI tools with primary care clinic workflows is an element of successful implementation of AI-aided DR testing.
“Elements of successful implementation include proper site selection, aligning AI tools with primary care clinic workflows, streamlining patient engagement and referrals, and ongoing training of staff.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Interpretationnone given
Ongoing training of staff is an element of successful implementation of AI-aided DR testing.
“Elements of successful implementation include proper site selection, aligning AI tools with primary care clinic workflows, streamlining patient engagement and referrals, and ongoing training of staff.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Study design and conductown data
Interviews were conducted with 6 ophthalmologists who lead implementation of AI DR testing programs at academic health systems.
“interviews were conducted with 6 ophthalmologists who lead implementation of AI DR testing programs at academic health systems.”
Quote in the paperSubstantial claim - Interpretationown data
AI-aided diabetic eye examinations present a promising solution to facilitate early detection of DR.
“Artificial intelligence–aided diabetic eye examinations present a promising solution to facilitate early detection of DR, promote equitable access, and drive down system-level cost of care.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Interpretationown data
AI-aided diabetic eye examinations present a promising solution to promote equitable access.
“Artificial intelligence–aided diabetic eye examinations present a promising solution to facilitate early detection of DR, promote equitable access, and drive down system-level cost of care.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
- Premisenone given
Institutions such as the Diabetes Center Mergentheim, Tübingen University Hospital, and >25 centers in Italy have adopted EyeArt.
“Institutions such as the Diabetes Center Mergentheim, Tübingen University Hospital, and >25 centers in Italy have adopted this technology.”
Quote in the paperNot a substantial claim - Premisecitation
Based on the Medicare Physician Fee Schedule look-up tool, the national payment amount for autonomous AI eye examination was $47.06 in 2022, $45.74 in 2023, and $40.28 in 2024.
“Based on the Medicare Physician Fee Schedule look-up tool, the national payment amount was $47.06 in 2022, $45.74 in 2023, and $40.28 in 2024.58”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [58] Anon Search the physician fee schedule https://www.cms.gov/medicare/physician-fee-schedule/search?Y=1&T=4&HT=0&CT=0&H1=92229&M=5
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
In randomized clinical trials, LumineticsCore has demonstrated safety in youth with diabetes.
“In randomized clinical trials, this system has shown to improve health equity in minorities26 and physician productivity,8 as well as demonstrated safety, efficacy, and equity in youth with diabetes.7”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [7] Wolf R.M. Liu T.Y.A. Thomas C. The SEE study: safety, efficacy, and equity of implementing autonomous artificial intelligence for diagnosing diabetic retinopathy in youth Diabetes Care 44 2021 781 787 33479160 source
- Premisecitation
Historically, the process of retinal eye examination for patients with diabetes had a compliance rate below 50%.
“Historically, this is a process with <50% compliance rate.55”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [55] Anon Comprehensive Diabetes Care. NCQA https://www.ncqa.org/hedis/measures/comprehensive-diabetes-care/ 2018
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
In randomized clinical trials, LumineticsCore has shown to improve health equity in minorities.
“In randomized clinical trials, this system has shown to improve health equity in minorities26 and physician productivity,8 as well as demonstrated safety, efficacy, and equity in youth with diabetes.7”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [26] Wolf R.M. Channa R. Liu T.Y.A. Autonomous artificial intelligence increases screening and follow-up for diabetic retinopathy in youth: the ACCESS randomized control trial Nat Commun 15 2024 1 9 38212308 PMC10784572 source
- Premisecitation
Stanford University, which already had a telemedicine screening program before introducing AI, achieved an additional 8% increase in annual examination adherence rate (65.2%-72.8%) in AI-clinics.
“Stanford University already had a telemedicine screening program before introducing AI but achieved an additional 8% increase in annual examination adherence rate (65.2%–72.8%) in AI-clinics.56”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [56] Knapp A.N. Dow E. Chen K. Real world outcomes from artificial intelligence to detect diabetic retinopathy in the primary care setting: 12 month experience Invest Ophthalmol Vis Sci 64 2023 252
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
At health systems with large patient volume, referral of all patients to ophthalmology for annual eye examination creates long wait times that could lead to patients being lost to follow-up or seeking care elsewhere.
“Particularly at health systems with large patient volume, this creates long wait times for an appointment that could lead to either the patient being lost to follow-up or seeking care elsewhere.”
Quote in the paperSubstantial claim- Rests on an assumption: Previously, retinal eye examination required patients to schedule and attend a second appointment with ophthalmology after receiving a referral from primary care.
- Premisecitation
Providers are reimbursed for autonomous AI eye examinations under CPT code 92229 created in 2019 by Centers for Medicare and Medicaid Services.
“Providers are reimbursed for autonomous AI eye examinations under CPT code 92229 created in 2019 by Centers for Medicare and Medicaid Services: “Imaging of retina for detection or monitoring of disease; point-of-care automated analysis and report, unilateral or bilateral.””
Quote in the paperSubstantial claim - Interpretationreasoning
The increase in screening rates observed with autonomous AI is a result of the evolution in screening process unlocked by the AI technology, rather than the software itself.
“One shall note that the increase in screening rates is a result of the evolution in screening process unlocked by the AI technology, rather than the software itself.”
Quote in the paperSubstantial claim - Premisecitation
Retinal eye examination is one of the 6 HEDIS measures for patients with diabetes.
“Retinal eye examination is one of the 6 HEDIS measures for patients with diabetes.54”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [54] Anon HEDIS measures and technical resources. NCQA https://www.ncqa.org/hedis/measures/ 2023
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
In randomized clinical trials, LumineticsCore has demonstrated equity in youth with diabetes.
“In randomized clinical trials, this system has shown to improve health equity in minorities26 and physician productivity,8 as well as demonstrated safety, efficacy, and equity in youth with diabetes.7”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [7] Wolf R.M. Liu T.Y.A. Thomas C. The SEE study: safety, efficacy, and equity of implementing autonomous artificial intelligence for diagnosing diabetic retinopathy in youth Diabetes Care 44 2021 781 787 33479160 source
- Interpretationreasoning
With autonomous AI, family practitioners can capture patients at their primary care appointments and perform retinal eye examinations before they leave the door.
“With autonomous AI, family practitioners can now capture patients at their primary care appointments and perform retinal eye examinations before they leave the door.”
Quote in the paperSubstantial claim - Premisecitation
In randomized clinical trials, LumineticsCore has demonstrated efficacy in youth with diabetes.
“In randomized clinical trials, this system has shown to improve health equity in minorities26 and physician productivity,8 as well as demonstrated safety, efficacy, and equity in youth with diabetes.7”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [7] Wolf R.M. Liu T.Y.A. Thomas C. The SEE study: safety, efficacy, and equity of implementing autonomous artificial intelligence for diagnosing diabetic retinopathy in youth Diabetes Care 44 2021 781 787 33479160 source
- Premisecitation
In a retrospective review of 241 patients, Shou et al's predictive dilation model using type 1 diabetes, smoking, age, race, sex, and hypertension achieved an area under the receiver operating characteristics curve of 0.76, with sensitivity of 77% and specificity of 68% at 50% cutoff value.
“The model demonstrated an area under the receiver operating characteristics curve of 0.76, with sensitivity of 77% and specificity of 68% at 50% cutoff value.45”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [45] Shou B.L. Venkatesh K. Chen C. Risk factors for nondiagnostic imaging in a real-world deployment of artificial intelligence diabetic retinal examinations in an integrated health care system: maximizing workflow efficiency through predictive dilation J Diabetes Sci Technol 18 2023 19322968231201654 PMC10973867 37798955 source
- Interpretationnone given
On the back end, workflow changes are enabled by the information technology team, which plays a crucial role in supporting camera setup and integration of the AI system with EMR.
“On the back end, the workflow changes are enabled by the information technology team, which plays a crucial role in supporting camera setup and integration of the AI system with EMR.”
Quote in the paperNot a substantial claim - Premisecitation
In the United States, Fuller et al's 5-year cost-effective model in a local low-income population demonstrated 23.3% cost savings using Automated Retinal Image Analysis System-based DR testing in a primary care medicine clinic.
“In the United States, Fuller et al zoomed in on a local low-income population and built a 5-year cost-effective model, which demonstrated 23.3% cost savings using Automated Retinal Image Analysis System–based DR testing in a primary care medicine clinic.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Fuller et al
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
Some patient factors correlated to nondiagnostic image include type 1 diabetic mellitus, smoking, old age, and cataracts.
“Some patient factors correlated to nondiagnostic image include type 1 diabetic mellitus, smoking, old age, and cataracts.45,49”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [45] Shou B.L. Venkatesh K. Chen C. Risk factors for nondiagnostic imaging in a real-world deployment of artificial intelligence diabetic retinal examinations in an integrated health care system: maximizing workflow efficiency through predictive dilation J Diabetes Sci Technol 18 2023 19322968231201654 PMC10973867 37798955 source
- cites [49] Najac T. Nelson C. McMurtry S. Identifying causes of ungradable fundus photos in an artificial intelligence assisted screening program for diabetic retinopathy Invest Ophthalmol Vis Sci 64 2023 228
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
At Stanford, a hybrid workflow routing AI-ungradable nonmydriatic images to retina specialists at the Stanford Reading Center increases overall gradability of nonmydriatic images to 95.6% of encounters.
“With this process, the overall gradability of nonmydriatic images increases to 95.6% of encounters, as the human expert graders in this system are experienced retina specialists and have greater capacity for interpreting lower quality nonmydriatic images than the AI is currently programmed to accept.46”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [46] Dow E.R. Khan N.C. Chen K.M. AI-Human hybrid workflow enhances teleophthalmology for the detection of diabetic retinopathy Ophthalmol Sci 3 2023 100330 PMC10336195 37449051 source
- Premisecitation
Nelson et al found it helpful to add an additional camera supervisor and patient care navigator.
“Nelson et al50 found it helpful to add an additional camera supervisor and patient care navigator.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [50] Nelson C. Najac T. Luong A. Evaluating Follow-Up metrics in an AI-Assisted telemedicine screening program for diabetic retinopathy in primary care clinics after hiring a patient care navigator Invest Ophthalmol Vis Sci 64 2023 2274
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Classified as probably not a substantial claim. 32
- May combine two claims. 37
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationLumineticsCore diagnoses according to the ETDRS and Diabetic Retinopathy Clinical Research network grading system to detect ETDRS level 35 or higher or central-involved diabetic macular edema or clinically significant diabetic macular edema.
“LumineticsCore diagnoses according to the ETDRS and Diabetic Retinopathy Clinical Research network grading system to detect ETDRS level 35 or higher (mild or moderate DR depending on the classification system) or central-involved diabetic macular edema or clinically significant diabetic macular edema.12”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [12] Channa R. Wolf R.M. Simo R. A new approach to staging diabetic eye disease: staging of diabetic retinal neurodegeneration and diabetic macular edema Ophthalmol Sci 4 2024 100420 PMC10818256 38284099 source
The Validation of the Artificial Intelligence System and Nonmaleficence section identifies the ETDRS and Diabetic Retinopathy Clinical Research Network scales as prognostic standards and discusses center-involved versus clinically significant macular edema. It does not say that LumineticsCore uses those scales or detects ETDRS level 35 or higher. Searches for LumineticsCore, the level-35 threshold, and related diagnostic-system terms found no passage establishing those device-specific claims. (LLM, conf=0.74)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductcitationThe 2018 Abramoff et al trial was developed under a strict ethical framework.
“developed under a strict ethical framework.16,17”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [16] Abràmoff M.D. Cunningham B. Patel B. Foundational considerations for artificial intelligence using ophthalmic images Ophthalmology 129 2022 e14 e32 34478784 PMC9175066 source
The Bioethical Foundation section says an ethical framework is essential for identifying concerns in AI development and describes principles for designing and validating AI systems. The References section identifies the 2018 Abràmoff et al. pivotal trial, but the paper does not say that this specific trial was developed under the framework or characterize its framework as strict. Page numbers were not available in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [17] Char D.S. Abràmoff F.C. Identifying ethical considerations for machine learning healthcare applications Am J Bioeth 20 2020 7 17 PMC7737650 33103967 source
The Abstract cites Abràmoff et al. (2018) as an example of an autonomous AI diagnostic system, and the References identify its pivotal trial. The pipeline-framework section proposes ethical considerations for machine-learning healthcare applications generally; it does not say the 2018 trial was developed under a strict ethical framework. Searches for the trial and for an ethical framework yielded no passage establishing that claim. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationLumineticsCore is directly connected to the camera and interfaces directly with all available electronic medical record for ordering, billing, and resulting directly.
“The system, which is directly connected to the camera, interfaces directly with all available electronic medical record (EMR) for ordering, billing, and resulting directly.13”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [13] Anon TRC-NW400 non-mydriatic retinal camera from topcon healthcare https://www.ophthalmologyweb.com/5740-Digital-Retinal-Camera/6016878-TRC-NW400-Non-Mydriatic-Retinal-Camera/ source
The Implementation, Evaluation, and Oversight section discusses electronic medical record platforms and a hypothetical diabetic-retinopathy diagnostic system, but does not describe LumineticsCore’s connections or interfaces. Searches for camera and EMR integration, ordering, billing, and resulting found no passage addressing those capabilities; page numbers were unavailable in our copy. (LLM, conf=0.74)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationDigital Diagnostics filed a 510(k) application for the current version of LumineticsCore based on the previous IDx-DR as predicate device, and it was cleared in May 2021 with the same De Novo special controls in place.
“Two years later, Digital Diagnostics filed a 510(k) application for the current version of LumineticsCore based on the previous IDx-DR as predicate device, which was subsequently cleared in May 2021, with the same De Novo special controls in place, which now apply to all 510(k)s.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [18] Anon [no title] https://www.accessdata.fda.gov/cdrh_docs/pdf20/K203629.pdf source
The Methods > Interventions passage identifies IDx-DR as a Digital Diagnostics device and says it received FDA De Novo authorization in 2018. It does not address LumineticsCore, a 510(k) filing or predicate designation, clearance in May 2021, or whether the same special controls applied. (LLM, conf=0.80)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationThe 2018 Abramoff et al trial reported a sensitivity of 87.2%, specificity of 90.7%, and gradability of 96.1% for referrable DR.
“reporting a sensitivity of 87.2%, specificity of 90.7%, and gradability of 96.1% for referrable DR”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] Abràmoff M.D. Lavin P.T. Birch M. Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices NPJ Digit Med 1 2018 39 31304320 PMC6550188 source
May combine two claims.
PremisecitationIn 2018, Abramoff et al published a preregistered prospective clinical trial, a first of its kind in any field of medicine, with n = 900 fully screened patients in primary care by operators without previous experience.
“However, in 2018, Abramoff et al15 published a preregistered prospective clinical trial, a first of its kind in any field of medicine, with n = 900 fully screened patients in primary care by operators without previous experience”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] Abràmoff M.D. Lavin P.T. Birch M. Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices NPJ Digit Med 1 2018 39 31304320 PMC6550188 source
Methods (Study design and Site initiation) describes a prospective study at 10 primary care sites with 900 enrolled participants, a prespecified protocol, and operators who had no prior ocular-imaging experience before receiving four hours of training. Results (Study population) says only 892 completed all procedures and 819 could be fully analyzed, so 900 were not fully screened. The Abstract calls the system the first FDA-authorized autonomous AI diagnostic system in any field of medicine; it does not make that first-of-its-kind claim about the trial. (LLM, conf=0.91)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationEyenuk's commercial launch of EyeArt began in the European Union in 2016 after receiving a Conformité Européenne Mark, when the system was only approved for investigational use in the United States.
“Eyenuk’s commercial launch of EyeArt began in the European Union in 2016 after receiving a Conformité Européenne Mark, when the system was only approved for investigational use in the United States.”
Quote in the paperNot a substantial claim3 of 3 sources checked- cites [29] Anon Eyenuk, inc. Expands into Germany with launch of EyeArt® artificial intelligence eye screening for diabetic retinopathy - Eyenuk, Inc. ∼ Artificial Intelligence Eye Screening. Eyenuk, Inc ∼ Artificial Intelligence Eye Screening https://www.eyenuk.com/us-en/articles/blog/eyenuk-inc-expands-into-germany-with-launch-of-eyeart-artificial-intelligence-eye-screening-for-diabetic-retinopathy 2018 source
The section “Example of an autonomous AI: IDx-DR” discusses FDA clearance in 2018 for IDx-DR, a different system. Searches for EyeArt, Eyenuk, the 2016 EU launch, CE marking, and investigational use in the United States found no passage addressing the claim in our copy. (LLM, conf=0.76)
Experimental — accuracy not yet measured - cites [30] Anon EyeArt used to screen for diabetic retinopathy in over 25 centers across Italy - Eyenuk, Inc. ∼ Artificial Intelligence Eye Screening. Eyenuk, Inc ∼ Artificial Intelligence Eye Screening https://www.eyenuk.com/us-en/success-stories/europe/eyeart-used-to-screen-for-diabetic-retinopathy-in-over-25-centers-across-italy 2020 source
The Image Acquisition, Imageability, and Diagnosability section discusses EyeArt’s pivotal trial, but not its commercial launch. Searches for the 2016 European Union launch, CE marking, and investigational-use status in the United States found no passage addressing those claims. (LLM, conf=0.75)
Experimental — accuracy not yet measured - cites [31] Anon Top German diabetes centers adopt eyenuk AI technology - eyenuk, inc. ∼ artificial intelligence eye screening. Eyenuk, inc ∼ artificial intelligence eye screening 2021 https://www.eyenuk.com/us-en/articles/eyeart/german-diabetes-centers-adopt-eyenuk-ai source
The Introduction describes IDx-DR by Digital Diagnostics and its FDA approval, not EyeArt by Eyenuk. Searches of our copy for EyeArt, Eyenuk, the 2016 EU launch, CE marking, and investigational use in the United States found no passage addressing the claim. No page number was provided for the Introduction passage. (LLM, conf=0.76)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationArtificial intelligence algorithms have demonstrated a high sensitivity of 95% to 100% in clinical implementation, whereas specificity is relatively lower and with greater variation at 60% to 90%.
“Artificial intelligence algorithms have demonstrated a high sensitivity of 95% to 100% in clinical implementation, whereas specificity is relatively lower and with greater variation at 60% to 90%.38,40,41,46”
Quote in the paperSubstantial claim1 of 4 sources checked- cites [38] Verbraak F.D. Abramoff M.D. Bausch G.C.F. Diagnostic accuracy of a device for the automated detection of diabetic retinopathy in a primary care setting Diabetes Care 42 2019 651 656 30765436 source
The Results report 100% sensitivity for vision-threatening diabetic retinopathy, supporting one endpoint of the claimed sensitivity range. But sensitivity for more-than-mild disease was 79.4%, and specificity was 97.8% and 93.8% for the two outcomes—neither within the claimed 60%–90% range. The paper evaluates one device, not algorithms generally. (LLM, conf=0.90)
Experimental — accuracy not yet measured - cites [40] Mehra A.A. Softing A. Guner M.K. Diabetic retinopathy telemedicine outcomes with artificial intelligence-based image analysis, reflex dilation, and image overread Am J Ophthalmol 244 2022 125 132 35970206 source
- cites [41] Mokhashi N. Grachevskaya J. Cheng L. A comparison of artificial intelligence and human diabetic retinal image interpretation in an urban health system J Diabetes Sci Technol 16 2022 1003 1007 33719599 PMC9264425 source
- cites [46] Dow E.R. Khan N.C. Chen K.M. AI-Human hybrid workflow enhances teleophthalmology for the detection of diabetic retinopathy Ophthalmol Sci 3 2023 100330 PMC10336195 37449051 source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationIn 2018, Health Canada approved EyeArt, allowing its sale in Canada.
“In 2018, Health Canada approved EyeArt, allowing its sale in Canada.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [32] Anon. Eyenuk, inc. Receives health Canada approval for EyeArtTM, an AI-enabled cloud-based automated diabetic retinopathy screening software - eyenuk, inc. ∼ artificial intelligence eye screening. Eyenuk, Inc ∼ Artificial Intelligence Eye Screening https://www.eyenuk.com/us-en/articles/blog/eyenuk-inc-receives-health-canada-approval-for-eyeart-an-ai-enabled-cloud-based-automated-diabetic-retinopathy-screening-software 2018 source
Our copy discusses U.S. FDA authorization of IDx-DR in the introductory passage following Financial Disclosure(s), but does not address EyeArt’s Canadian regulatory status. Searches for EyeArt, Health Canada, and Canadian approval found no passage stating that Health Canada approved EyeArt in 2018 or permitted its sale. (LLM, conf=0.76)
Experimental — accuracy not yet measured
May combine two claims.
InterpretationcitationAmidst rising DR prevalence, autonomous AI testing presents a promising solution to facilitate early detection, promote equitable access, and drive down system-level cost of care.
“Amidst rising DR prevalence, autonomous AI testing presents a promising solution to facilitate early detection, promote equitable access, and drive down system-level cost of care.42,48,67”
Quote in the paperSubstantial claim3 of 3 sources checked- cites [42] Fuller S.D. Hu J. Liu J.C. Five-year cost-effectiveness modeling of primary care-based, nonmydriatic automated retinal image analysis screening among low-income patients with diabetes J Diabetes Sci Technol 16 2022 415 427 33124449 PMC8861785 source
Section 12.3 identifies FDA-authorized AI systems as an alternative for diabetic-retinopathy screening and explains why prompt detection matters. It attributes improved access and possible cost savings to retinal photography with remote expert reading, not specifically to autonomous AI, and says the benefits and optimal use of AI screening remain undetermined. The cited passages do not establish rising retinopathy prevalence. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [48] Huang J. Wang J. Channa R. Autonomous artificial intelligence exams are associated with higher adherence to diabetic retinopathy testing in an integrated healthcare system Invest Ophthalmol Vis Sci 64 2023 212 source
- cites [67] Huang X. Wang H. She C. Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy Front Endocrinol 13 2022 946915 PMC9559815 36246896 source
- Rests on an assumption: Vulnerable populations served by Federally Qualified Health Centers lack access to specialist resources.
May combine two claims.
PremisecitationIn the pivotal trial that led to the clearance of LumineticsCore, 76.4% of participants received results without pharmacologic dilation, and an additional 23.6% became gradable with dilation.
“In the pivotal trial that led to the clearance of LumineticsCore, 76.4% of participants received results without pharmacologic dilation, and an additional 23.6% became gradable with dilation.15”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [15] Abràmoff M.D. Lavin P.T. Birch M. Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices NPJ Digit Med 1 2018 39 31304320 PMC6550188 source
The Results (AI system characteristics; page unavailable) report that 76.4% did not require pharmacologic dilation and 23.6% required it to obtain an AI-system disease-level output, supporting the numerical claim. The Discussion says the trial helped lead to FDA authorization, but the paper identifies the system as IDx-DR, not LumineticsCore; our copy does not establish that product-name connection. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Findingnone givenBased on public records at the time of writing, both LumineticsCore and EyeArt have more than 5 academic adopters in the United States.
“Based on public records at the time of writing, both LumineticsCore and EyeArt have >5 academic adopters in the United States.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingown dataAdditional articles, of which 18 were selected for detailed review, addressed impact on patient adherence, health equity, and carbon footprint, as well as cost-effectiveness and workflow efficiency analyses.
“Additional articles, of which 18 were selected for detailed review, addressed impact on patient adherence, health equity, and carbon footprint, as well as cost-effectiveness and workflow efficiency analyses.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe literature review found 6 publications reporting diagnostic accuracy data of autonomous AI DR testing in primary care office settings, including 5 for LumineticsCore and 1 for EyeArt.
“The literature review found 6 publications reporting diagnostic accuracy data of autonomous AI DR testing in primary care office settings, including 5 for LumineticsCore and 1 for EyeArt.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
FindingreasoningThe final selection was 18 articles for detailed analysis.
“resulting in a final selection of 18 articles for detailed analysis.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
FindingreasoningLimited information is available on AEYE-DS given the recency of its regulatory clearance.
“Limited information is available on AEYE-DS given recency of regulatory clearance.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based). May combine two claims.
Findingnone givenAI-aided diabetic retinopathy testing systems have been commercialized for 5 years, but adoption is still relatively limited.
“Artificial intelligence (AI)–aided diabetic retinopathy (DR) testing systems have been commercialized for 5 years, but adoption is still relatively limited.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Findingnone givenAnecdotally, ophthalmologists have observed that patients referred to clinics are more likely to be disease-positive without change in overall volume after AI program roll-out.
“Anecdotally, ophthalmologists have observed that patients referred to clinics are more likely to be disease-positive without change in overall volume after AI program roll-out.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Findingnone givenUniversally, leaders in ophthalmology departments have leaned into the effort to implement these systems.
“Universally, leaders in ophthalmology departments have leaned into the effort to implement these systems.”
Quote in the paperNot a substantial claim- Rests on an assumption: Today, LumineticsCore is utilized in >1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.
- Rests on an assumption: To date, EyeArt has been utilized in the United States by institutions such as Temple Health, University of Utah Health, and Cedars Sinai Health System.
- Rests on an assumption: To our best knowledge, AEYE-DS has been implemented in select community-based health organizations in the United States, such as the Bethesda Health Clinic.
May combine two claims.
Findingown dataWhen a health system pursued implementation in a research context without top-down support, research staff tested patients without disrupting the regular visit workflow, and after the study the camera was returned and the system was not implemented.
“In contrast, when a health system pursued implementation in a research context without top-down support, research staff visited primary care offices and tested patients without disrupting the regular visit workflow. Upon conclusion of the research study, the camera was returned to the manufacturer and the system was not implemented.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataBased on publicly available information, both LumineticsCore and EyeArt each have around 5 academic adopters in the United States today.
“Based on publicly available information (from press release, academic publications), both LumineticsCore and EyeArt each have around 5 academic adopters in the United States today (Table 1, Table 2).”
Quote in the paperNot a substantial claim- Rests on an assumption: Today, LumineticsCore is utilized in >1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.
- Rests on an assumption: To date, EyeArt has been utilized in the United States by institutions such as Temple Health, University of Utah Health, and Cedars Sinai Health System.
Probably not a substantial claim: may not pass S3 (load-bearing).
Findingown dataOphthalmology departments contribute numerous peer-reviewed articles and abstracts to describe their practical experience since 2018.
“These departments also contribute numerous peer-reviewed articles and abstracts to describe their practical experience since 2018 (Table 3).”
Quote in the paperNot a substantial claim- Rests on an assumption: Today, LumineticsCore is utilized in >1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.
- Rests on an assumption: To date, EyeArt has been utilized in the United States by institutions such as Temple Health, University of Utah Health, and Cedars Sinai Health System.
- Rests on an assumption: To our best knowledge, AEYE-DS has been implemented in select community-based health organizations in the United States, such as the Bethesda Health Clinic.
May combine two claims.
Findingown dataThe department collecting payment for autonomous AI eye examinations varies across health systems; among adopters interviewed, about half attribute payments to the primary care department and the other half to ophthalmology.
“Interestingly, the department collecting the payment varies across health systems. Among the adopters we interviewed with, about half attribute payments to the primary care department, and the other half to ophthalmology.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataTwo hospitals became interested in autonomous AI testing of DR to improve primary care HEDIS scores; with this objective articulated and priorities set, implementation followed as a coordinated effort between ophthalmology and primary care.
“For instance, 2 hospitals became interested in autonomous AI testing of DR as an effort to improve primary care HEDIS scores. With this objective articulated and priorities set, implementation followed as a coordinated effort between ophthalmology and primary care.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataIn terms of staffing, 80% of the health systems did not add dedicated full-time equivalent to launch the AI program, although more than half of adopters interviewed expressed "wish we could."
“In terms of staffing, 80% of the health systems did not add dedicated full-time equivalent to launch the AI program, although more than half of adopters we interviewed expressed “wish we could.””
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone givenThe study adhered to the Declaration of Helsinki and informed consent was waived and was institutional review board exempt.
“Our study adhered to the Declaration of Helsinki and informed consent was waived and was institutional review board exempt.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenCurrently, there are 3 commercially available US FDA-cleared systems for DR testing: LumineticsCore, EyeArt, and AEYE-DS.
“Currently, there are 3 commercially available US FDA–cleared systems for DR testing: LumineticsCore (previously IDx-DR) by Digital Diagnostics, EyeArt by Eyenuk, Inc, and AEYE-DS by AEYE Health, Inc.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
InterpretationreasoningSuccessful implementation of AI-aided diabetic eye examinations requires addressing technological, operational, and stakeholder engagement challenges.
“Its successful implementation requires addressing technological, operational, and stakeholder engagement challenges.”
Quote in the paperSubstantial claim- Rests on an assumption: The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenIn late 2022, AEYE-DS was cleared through 510(k) using the same predicate as LumineticsCore.
“In late 2022, a third system, AEYE Diagnostic Screening (AEYE-DS), was also cleared through 510(k) using the same predicate.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenToday, DR remains the only indication in medicine where an AI system can provide an image analysis decision without clinician interpretation.
“Today, DR remains the only indication in medicine where an AI system can provide an image analysis decision without clinician interpretation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationImaging-based diagnostics is one of the earliest frontiers of AI development and has been cited by healthcare professionals as the most common application of AI solutions in health care today.
“Imaging-based diagnostics is one of the earliest frontiers of AI development and has been cited by healthcare professionals as the most common application of AI solutions in health care today.1”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [1] Spatharou A. Hieronimus S. Jenkins J. Transforming healthcare with AI: The impact on the workforce and organizations 2020 McKinsey & Company https://www.mckinsey.com/industries/healthcare/our-insights/transforming-healthcare-with-ai
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenDigital Diagnostics is the first autonomous AI company to receive the US FDA De Novo pathway clearance for DR testing.
“Digital Diagnostics is the first autonomous AI company to receive the US FDA De Novo pathway clearance for DR testing.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenLumineticsCore is an AI diagnostic system designed to autonomously diagnose patients for mtmDR, central-involved diabetic macular edema traditionally diagnosed with OCT, and clinically significant diabetic macular edema diagnosed with fundus photographs, using images acquired with a Topcon TRC-NW400 camera.
“Their product, LumineticsCore (originally known as IDx-DR), is an AI diagnostic system designed to autonomously diagnose patients for mtmDR, central-involved diabetic macular edema traditionally diagnosed with OCT, and clinically significant diabetic macular edema diagnosed with fundus photographs, using images acquired with a Topcon TRC-NW400 camera (Topcon).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductown dataTwo independent reviewers screened titles and abstracts for relevance, followed by full-text assessment.
“Two independent reviewers (C.T. and S.P.) screened titles and abstracts for relevance, followed by full-text assessment.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Study design and conductnone givenA systematic search was conducted across electronic databases including PubMed, Google Scholars, Scopus, and Web of Science.
“A systematic search was conducted across electronic databases, including PubMed, Google Scholars, Scopus, and Web of Science.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationWithout a screening program, all patients diagnosed with type 1 diabetic mellitus and type 2 diabetic mellitus are referred for an annual eye examination.
“Without a screening program, all patients diagnosed with type 1 diabetic mellitus and type 2 diabetic mellitus are referred for an annual eye examination;46”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] Dow E.R. Khan N.C. Chen K.M. AI-Human hybrid workflow enhances teleophthalmology for the detection of diabetic retinopathy Ophthalmol Sci 3 2023 100330 PMC10336195 37449051 source
May combine two claims.
InterpretationcitationThe accuracy and low dilation requirement distinguish the AEYE-DS system from the other 2 commercially available systems.
“Though the enhanced efficiency and potential pitfalls in clinical workflows of taking 1 image versus 2 images per eye have yet to be studied, the accuracy and low dilation requirement distinguish the AEYE-DS system from the other 2 commercially available systems.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [37] Anon. CTG labs - NCBI https://clinicaltrials.gov/study/NCT04612868 source
May combine two claims.
InterpretationreasoningWhen autonomous AI performs the first round of testing and refers only patients with positive or ungradable examinations, ophthalmologists can focus attention on those most likely to have disease and patient access to appointments and treatment improves.
“When autonomous AI performs the first round of testing and refers only the patients with positive or ungradable examinations, this allows ophthalmologists to focus attention on those who are most likely to have disease and improve patient access to appointments and treatment.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationIn 2021, Centers for Medicare and Medicaid Services established relative value units for autonomous AI eye examination and a national payment rate.
“In 2021, Centers for Medicare and Medicaid Services established relative value units for this service and national payment rate.57”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [57] Larson P.M. Medicare: what's new for 2022 https://www.reviewofophthalmology.com/article/medicare-whats-new-for-2022 2022
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationAEYE-DS requires only 1 image per eye (macula-centered color fundus images with ≥45° field of view) for diagnosis and requires dilation in <1% of patients.
“The system requires only 1 image per eye (ie, macula-centered color fundus images with ≥45° field of view) for diagnosis and requires dilation in <1% of patients.37”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [37] Anon. CTG labs - NCBI https://clinicaltrials.gov/study/NCT04612868 source
May combine two claims.
PremisecitationA 2023 study by Najac et al found that overall image quality in telemedical general practitioner-based diabetic eye disease testing with EyeArt was sufficient and would be accepted by both medical assistants and patients in most cases.
“Their study found that the overall image quality achieved in this telemedical general practicioner-based diabetic eye disease testing was sufficient and would be accepted by both medical assistants and patients in most cases.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [35] Wintergerst M.W.M. Bejan V. Hartmann V. Telemedical diabetic retinopathy screening in a primary care setting: quality of retinal photographs and accuracy of automated image analysis Ophthalmic Epidemiol 29 2022 286 295 34151725 source
- cites [36] Hutton D. Eyenuk receives FDA clearance for additional camera for autonomous detection of diabetic retinopathy. Ophthalmology Times https://www.ophthalmologytimes.com/view/eyenuk-receives-fda-clearance-for-additional-camera-for-autonomous-detection-of-diabetic-retinopathy 2023
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenIf the scheduling system is fully integrated into the EMR, primary care can schedule the ophthalmology appointment before the patient leaves.
“If the scheduling system is fully integrated into the EMR, primary care can schedule the ophthalmology appointment before the patient leaves.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningCompared to a human-interpretation model, autonomous AI testing frees ophthalmologists from the time commitment of image batch reads and allows focus on in-person patient care.
“Compared to a human-interpretation model (Fig 1, Workflow 2), this also frees ophthalmologists from the time commitment of image batch reads and focuses on in-person patient care.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable). May combine two claims.
InterpretationreasoningA pilot affords the opportunity to gather feedback, refine processes, and build confidence across the network to prepare for scaling.
“A pilot also affords the opportunity to gather feedback, refine processes, and build confidence across the network to prepare for scaling.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenWhen executed well, an AI-aided DR testing program can create value and efficiency for the health system.
“When executed well, an AI-aided DR testing program can create value and efficiency for the health system in the following ways:”
Quote in the paperNot a substantial claim- Rests on an assumption: The 6 academic ophthalmology programs interviewed are representative of health systems adopting autonomous AI testing, so their experiences can be generalized.
May combine two claims.
InterpretationreasoningFrom the patients' perspective, integrating scheduling into the EMR improves access by eliminating the need to call to schedule and allowing the option to find earlier appointments for more urgent cases.
“From the patients’ perspective, there is also improved access as this eliminates the need to call to schedule and allows the option to find earlier appointments for more urgent cases.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe 2023 study by Najac et al highlighted challenges in ensuring good image quality and integrating the system into the existing workflow.
“However, the study also highlighted challenges in ensuring good image quality and integrating the system into the existing workflow.35,36”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [35] Wintergerst M.W.M. Bejan V. Hartmann V. Telemedical diabetic retinopathy screening in a primary care setting: quality of retinal photographs and accuracy of automated image analysis Ophthalmic Epidemiol 29 2022 286 295 34151725 source
- cites [36] Hutton D. Eyenuk receives FDA clearance for additional camera for autonomous detection of diabetic retinopathy. Ophthalmology Times https://www.ophthalmologytimes.com/view/eyenuk-receives-fda-clearance-for-additional-camera-for-autonomous-detection-of-diabetic-retinopathy 2023
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationEyenuk offers a "spellcheck"-like, assistive-AI function for ophthalmologists who read retinal images for other diseases such as glaucoma and age-related macular degeneration, which are not currently FDA-cleared for autonomous diagnosis.
“Of note, they also offer a “spellcheck”-like, assistive-AI function for ophthalmologists who read these images for other diseases such as glaucoma and age-related macular degeneration, which are not currently FDA-cleared for autonomous diagnosis.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [27] Lim G. Bellemo V. Xie Y. Different fundus imaging modalities and technical factors in AI screening for diabetic retinopathy: a review Eye Vis (Lond) 7 2020 21 32313813 PMC7155252 source
Probably not a substantial claim: may not pass S4 (based). May combine two claims.
InterpretationreasoningIntegrating scheduling into the EMR will drive internal referral and patient retention in the health system and reduce the workload to call patients for scheduling on the back end.
“This will not only drive internal referral and patient retention in the health system but also reduce the workload to call patients for scheduling on the back end.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
InterpretationreasoningLeadership by ophthalmology has the additional benefit of breeding future expansion of this technology into other ocular diseases, such as age-related macular degeneration and glaucoma.
“On this front, leadership by ophthalmology has the additional benefit of breeding future expansion of this technology into other ocular diseases, such as age-related macular degeneration and glaucoma.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationDow et al found that the AI algorithm is more sensitive than remote image interpretation by a retinal specialist (95.5% vs 69.5%) but had lower specificity (60.3% vs 96.9%).
“Stanford’s experience with this hybrid system was reported by Dow et al, who found that the AI algorithm is more sensitive than remote image interpretation by a retinal specialist (95.5% vs 69.5%) but had lower specificity (60.3% vs 96.9%).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Dow et al
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationIn September 2022, the FDA completed the Software Precertification Pilot Program, which was started in 2017, aimed to explore innovative approaches to regulatory oversight of medical device software.
“In September 2022, the FDA completed the Software Precertification Pilot Program, which was started in 2017, aimed to explore innovative approaches to regulatory oversight of medical device software.66”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [66] U.S. Food and Drug Administration, Others, Digital health software precertification (pre-cert) pilot program https://www.fda.gov/medical-devices/digital-health-center-excellence/digital-health-software-precertification-pre-cert-pilot-program 2022
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
PremisecitationIn Singapore, autonomous testing costs $11-15 less per patient per year, leading to an annual national savings of $15 million by 2050.
“In Singapore, it is estimated that autonomous testing costs $11-15 less per patient per year, leading to an annual national savings of $15 million by 2050.63”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [63] Xie Y. Nguyen Q.D. Hamzah H. Artificial intelligence for teleophthalmology-based diabetic retinopathy screening in a national programme: an economic analysis modelling study Lancet Digit Health 2 2020 e240 e249 33328056 source
May combine two claims.
PremisecitationMultiple studies have shown that diagnostic rates can be increased by a reflexive dilation protocol, but utilization has been found to be challenging.
“While multiple studies have shown that diagnostic rates can be increased by a reflexive dilation protocol,60,61 utilization has been found to be challenging.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [60] Deb-Joardar N. Germain N. Thuret G. Screening for diabetic retinopathy by ophthalmologists and endocrinologists with pupillary dilation and a nonmydriatic digital camera Am J Ophthalmol 140 2005 814 821 16310458 source
- cites [61] Banaee T. Ansari-Astaneh M.-R. Pourreza H. Utility of 1% tropicamide in improving the quality of images for tele-screening of diabetic retinopathy in patients with dark irides Ophthalmic Epidemiol 24 2017 217 221 28658588 source
Probably not a substantial claim: may not pass S4 (based). May combine two claims.
Premisenone givenAmong the 3 commercially available US FDA-cleared systems, both LumineticsCore and EyeArt have been implemented outside of trial conditions for 3 to 5 years with adequate levels of imageability and accuracy reported.
“Among the 3 commercially available US FDA–cleared systems, both LumineticsCore and EyeArt have been implemented outside of trial conditions for 3 to 5 years with adequate levels of imageability and accuracy reported.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationReflexive dilation protocol introduces another step in the primary care workflow in addition to a small patient risk, requiring the operator to be comfortable performing the procedure and understand relevant contraindications, as well as accommodation for added visit time and ensuring patients have transportation means.
“This introduces another step in the primary care workflow in addition to a small patient risk,62 requiring the operator to be comfortable performing the procedure and understand relevant contraindications, as well as accommodation for added visit time and ensuring patients have transportation means.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [62] Pandit R.J. Taylor R. Mydriasis and glaucoma: exploding the myth. A systematic review Diabet Med 17 2000 693 699 11110501 source
- Rests on an assumption: Image quality in fundus photography is affected by factors such as pupil size, patient positioning and compliance, and media opacities such as cataracts.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFuture algorithm improvements may trigger the requirement for a 510(k) premarket notification submission under guidelines for software changes published in 2017.
“future algorithm improvements may trigger the requirement for a 510(k) premarket notification submission under guidelines for software changes published in 2017.65”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [65] Center for Devices, Radiological Health Deciding when to submit a 510(k) for a software change to an existing device. US Food and Drug Administration https://www.fda.gov/regulatory-information/search-fda-guidance-documents/deciding-when-submit-510k-software-change-existing-device 2020
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
The paper relies on this without support.
The experiences and perspectives of the six interviewed ophthalmologists are representative of successful AI DR testing implementation across academic health systems.
“interviews were conducted with 6 ophthalmologists who lead implementation of AI DR testing programs at academic health systems.”
The paper relies on this without support.
In 2022, Centers for Medicare and Medicaid Services announced that they would be reimbursing LumineticsCore procedures under the physician fee schedule, and private payers soon followed.
“In 2022, Centers for Medicare and Medicaid Services announced that they would be reimbursing LumineticsCore procedures under the physician fee schedule, and private payers soon followed.”
The paper relies on this without support.
Today, LumineticsCore is utilized in >1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.
“Today, LumineticsCore is utilized in >1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.”
The paper relies on this without support.
To date, EyeArt has been utilized in the United States by institutions such as Temple Health, University of Utah Health, and Cedars Sinai Health System.
“To date, EyeArt has been utilized in the United States by institutions such as Temple Health, University of Utah Health, and Cedars Sinai Health System.”
The paper relies on this without support.
In 2020, EyeArt received FDA clearance under the 510(k) pathway using IDx-DR as the predicate device, and began its expansion into the United States.
“More recently, in 2020, the system received FDA clearance under the 510(k) pathway using IDx-DR as the predicate device, and began its expansion into the United States.”
The paper relies on this without support.
In October 2022, AEYE-DS received FDA clearance under the 510(k) pathway using IDx-DR as the predicate device.
“In October 2022, AEYE-DS received FDA clearance under the 510(k) pathway using IDx-DR as the predicate device.”
The paper relies on this without support.
To our best knowledge, AEYE-DS has been implemented in select community-based health organizations in the United States, such as the Bethesda Health Clinic.
“To our best knowledge, AEYE-DS has been implemented in select community-based health organizations in the United States, such as the Bethesda Health Clinic.”
The paper relies on this without support.
AI is not a standalone tool but a component in the overall design of a testing program for eye diseases.
“It is worth noting that AI is not a standalone, but rather a component in the overall design of a testing program for eye diseases.”
The paper relies on this without support.
The 6 academic ophthalmology programs interviewed are representative of health systems adopting autonomous AI testing, so their experiences can be generalized.
“Based on our interviews, the 6 academic ophthalmology programs agreed that buy-in from the primary care team is critical for initiating utilization of AI examinations.”
The paper relies on this without support.
In the traditional model, a considerable proportion of patients fail to follow up after being referred for ophthalmology assessment.
“In the traditional model, one of the challenges is that a considerable proportion of patients fail to follow up after being referred for ophthalmology assessment.”
The paper relies on this without support.
Image quality in fundus photography is affected by factors such as pupil size, patient positioning and compliance, and media opacities such as cataracts.
“Image quality in fundus photography is affected by a number of factors, such as pupil size, patient positioning and compliance, and media opacities such as cataracts.”
The paper relies on this without support.
Following Medicare and Medicaid, a growing number of commercial payers established reimbursement for autonomous AI eye examinations.
“Following Medicare and Medicaid, a growing number of commercial payers established reimbursement.”
The paper relies on this without support.
Previously, retinal eye examination required patients to schedule and attend a second appointment with ophthalmology after receiving a referral from primary care.
“Previously, this required patients to schedule and attend a second appointment with ophthalmology after receiving a referral from primary care.”
The paper relies on this without support.
LabCorp launched DR examinations with LumineticsCore at 9 locations in Alabama in April 2023.
“Another notable adopter on the horizon is LabCorp, who launched DR examinations with LumineticsCore at 9 locations in Alabama in April 2023.”
The paper relies on this without support.
Payment for the point-of-care diagnostic service is currently covered under CPT code 92229.
“Payment for the point-of-care diagnostic service is currently covered under CPT code 92229”
The paper relies on this without support.
Vulnerable populations served by Federally Qualified Health Centers lack access to specialist resources.
“Given the lack of access to specialist resources among the vulnerable population served by FQHCs”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Sensitivity-study count conflicts with Table 1
MinorThe abstract gives n = 3 for reported sensitivities, whereas Table 1 reports sensitivities for four institutions: Iowa, Mayo, Stanford, and Temple.
“sensitivity 87% to 100% (n = 3), and specificity 60% to 91% (n = 4).”
“| University of Iowa | LumineticsCore | 892 | 73.4% | 96.1% | 87.2% | 90.7% | 76% | 96% | 15 | | Mayo Clinic | LumineticsCore | 1052 | 55.1% | 91.7% | 100% | 89.2% | 27.5% | 100% | 40 | | Johns Hopkins University | LumineticsCore | 241 | 49% | N/A | N/A | N/A | N/A | N/A | 45 | | Stanford University | LumineticsCore | 80 | 71% | N/A | 96% | 60% | 48% | 97% | 46 | | Temple University | EyeArt | 260 | 75% | N/A | 100% | 78% | 19% | 100% | 41 |”
Conflicting creation dates for CPT code 92229
MinorOne passage says the CPT Editorial Panel created code 92229 in September 2020; another says it was created in 2019.
“Earlier in September 2020, the American Medical Association Current Procedural Terminology (CPT) Editorial Panel created code 92229 for retinal imaging with autonomous point-of-care interpretation”
“Providers are reimbursed for autonomous AI eye examinations under CPT code 92229 created in 2019 by Centers for Medicare and Medicaid Services”
Pivotal-trial gradability percentages conflict
MinorThe stated 76.4% receiving results without dilation plus an additional 23.6% becoming gradable with dilation implies 100% overall gradability. The paper reports 96.1% gradability for the pivotal trial.
“In the pivotal trial that led to the clearance of LumineticsCore, 76.4% of participants received results without pharmacologic dilation, and an additional 23.6% became gradable with dilation.15”
“reporting a sensitivity of 87.2%, specificity of 90.7%, and gradability of 96.1% for referrable DR”
Cites
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697 · see citing works
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638 · cited 4× · see citing works
“15 In practice, the nonmydriatic gradability is found to range from 49% to 75% (Table 1).”
InfluentialAbràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101 · cited 1× · see citing works
“14 However, in 2018, Abramoff et al 15 published a preregistered prospective clinical trial, a first of its kind in any field of medicine, with n = 900 fully screened patients in primary care by operators without previous experience reporting a sensitivity of 87.2%, specificity of 90.7%, and…”
InfluentialRajalakshmi, R., Subashini, R., Anjana, R. M., & Mohan, V. (2018) · Eye · doi:10.1038/s41433-018-0064-9 · Cited by 462 · see citing works
Identifying Ethical Considerations for Machine Learning Healthcare Applications
Char, D. S., Abràmoff, M. D., & Feudtner, C. (2020) · The American Journal of Bioethics · doi:10.1080/15265161.2020.1819469 · Cited by 415 · cited 1× · see citing works
“16,17 Of note, the statistics are calculated against a prognostic level 1 reference standard, meaning that rather than compare the performance against clinicians, it was compared against diagnostic modalities that include OCT imaging for central-involved diabetic macular edema.”
Saaddine, J. B. (2008) · Archives of Ophthalmology · doi:10.1001/archopht.126.12.1740 · Cited by 377 · see citing works
Lluch, M. (2011) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2011.09.005 · Cited by 358 · see citing works
Xie, Y., Nguyen, Q. D., Hamzah, H., Lim, G., Bellemo, V., Gunasekeran, D. V., Yip, M. Y. T., Qi Lee, X., Hsu, W., Li Lee, M., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30060-1 · Cited by 288 · see citing works
Automated Diabetic Retinopathy Image Assessment Software
Tufail, A., Rudisill, C., Egan, C., Kapetanakis, V. V., Salas-Vega, S., Owen, C. G., Lee, A., Louw, V., Anderson, J., Liew, G., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.11.014 · Cited by 283 · see citing works
Bhaskaranand, M., Ramachandra, C., Bhat, S., Cuadros, J., Nittala, M. G., Sadda, S. R., & Solanki, K. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0164 · Cited by 211 · cited 1× · see citing works
“34 A study in 2023 by Najac et al assessed the feasibility of telemedicine diabetic eye disease testing in a point-of-care general practice setting.”
12. Retinopathy, Neuropathy, and Foot Care: <i>Standards of Medical Care in Diabetes—2022</i>
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s012 · Cited by 177 · see citing works
Comprehensive review of the effects of diabetes on ocular health
Skarbez, K., Priestley, Y., Hoepf, M., & Koevary, S. B. (2010) · Expert Review of Ophthalmology · doi:10.1586/eop.10.44 · Cited by 117 · see citing works
Wolf, R. M., Channa, R., Liu, T. Y. A., Zehra, A., Bromberger, L., Patel, D., Ananthakrishnan, A., Brown, E. A., Prichett, L., Lehmann, H. P., et al. (2024) · Nature Communications · doi:10.1038/s41467-023-44676-z · Cited by 116 · cited 1× · see citing works
“In randomized clinical trials, this system has shown to improve health equity in minorities 26 and physician productivity, 8 as well as demonstrated safety, efficacy, and equity in youth with diabetes.”
Self-citationVerbraak, F. D., Abramoff, M. D., Bausch, G. C. F., Klaver, C., Nijpels, G., Schlingemann, R. O., & van der Heijden, A. A. (2019) · Diabetes Care · doi:10.2337/dc18-0148 · Cited by 115 · cited 1× · see citing works
“38,40,41,46 To improve the specificity of referral, Mayo Clinic and Stanford adopted an AI-human hybrid workflow (Fig 1, Workflow 4).”
Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy
Huang, X., Wang, H., She, C., Feng, J., Liu, X., Hu, X., Chen, L., & Tao, Y. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.946915 · Cited by 115 · see citing works
Characterizing the clinical adoption of medical AI devices through U.S. insurance claims
Wu, K., Wu, E., Theodorou, B., Liang, W., Mack, C., Glass, L., Sun, J., & Zou, J. (2024) · NEJM AI · doi:10.1056/aioa2300030 · Cited by 103 · cited 1× · see citing works
“21 LumineticsCore was also the first autonomous AI testing system to secure Medicare 22 and Medicaid reimbursement, 23 and qualify for Healthcare Effectiveness Data and Information Set (HEDIS) care gap closure 24 and Merit-based Incentive Payment System care gap closure.”
Lim, G., Bellemo, V., Xie, Y., Lee, X. Q., Yip, M. Y. T., & Ting, D. S. W. (2020) · Eye and Vision · doi:10.1186/s40662-020-00182-7 · Cited by 96 · cited 1× · see citing works
“27 Of note, they also offer a “spellcheck”-like, assistive-AI function for ophthalmologists who read these images for other diseases such as glaucoma and age-related macular degeneration, which are not currently FDA-cleared for autonomous diagnosis.”
Foundational Considerations for Artificial Intelligence Using Ophthalmic Images
Abràmoff, M. D., Cunningham, B., Patel, B., Eydelman, M. B., Leng, T., Sakamoto, T., Blodi, B., Grenon, S. M., Wolf, R. M., Manrai, A. K., et al. (2022) · Ophthalmology · doi:10.1016/j.ophtha.2021.08.023 · Cited by 96 · cited 1× · see citing works
“16,17 Of note, the statistics are calculated against a prognostic level 1 reference standard, meaning that rather than compare the performance against clinicians, it was compared against diagnostic modalities that include OCT imaging for central-involved diabetic macular edema.”
Self-citationMydriasis and glaucoma: exploding the myth. A systematic review
Pandit, R. J., & Taylor, R. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00368.x · Cited by 94 · cited 1× · see citing works
“This introduces another step in the primary care workflow in addition to a small patient risk, 62 requiring the operator to be comfortable performing the procedure and understand relevant contraindications, as well as accommodation for added visit time and ensuring patients have transportation…”
Liu, J., Gibson, E., Ramchal, S., Shankar, V., Piggott, K., Sychev, Y., Li, A. S., Rao, P. K., Margolis, T. P., Fondahn, E., et al. (2021) · Ophthalmology Retina · doi:10.1016/j.oret.2020.06.016 · Cited by 88 · cited 2× · see citing works
“42 Liu et al 39 found that among 180 study participants who underwent nonmydriatic fundus photography followed by automated retinal image analysis with human supervision, those referred for follow-up ophthalmic evaluation had an adherence rate of 55.4% at 1 year, compared with the historical adherence rate of 18.7%.”
InfluentialSelf-citationAbramoff, M. D., Whitestone, N., Patnaik, J. L., Rich, E., Ahmed, M., Husain, L., Hassan, M. Y., Tanjil, M. S. H., Weitzman, D., Dai, T., et al. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00931-7 · Cited by 81 · see citing works
Potential reduction in healthcare carbon footprint by autonomous artificial intelligence
Wolf, R. M., Abramoff, M. D., Channa, R., Tava, C., Clarida, W., & Lehmann, H. P. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00605-w · Cited by 63 · see citing works
Wolf, R. M., Liu, T. Y. A., Thomas, C., Prichett, L., Zimmer-Galler, I., Smith, K., Abramoff, M. D., & Channa, R. (2021) · Diabetes Care · doi:10.2337/dc20-1671 · Cited by 62 · cited 1× · see citing works
“7 Today, LumineticsCore is utilized in > 1000 US clinical sites spanning both academic health systems and community-based health organizations including Stanford Medicine, Johns Hopkins Health System, Cahaba Medical Care, and LabCorp, with expansion to sites outside the United States as well.”
Self-citationFuller, S. D., Hu, J. Q., Liu, J. C., Gibson, E., Gregory, M. H., Kuo, J., & Rajagopal, R. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820967011 · Cited by 60 · cited 2× · see citing works
“42,48,67 Among the 3 commercially available US FDA — cleared systems, both LumineticsCore and EyeArt have been implemented outside of trial conditions for 3 to 5 years with adequate levels of imageability and accuracy reported.”
InfluentialSelf-citationDow, E. R., Khan, N. C., Chen, K. M., Mishra, K., Perera, C., Narala, R., Basina, M., Dang, J., Kim, M., Levine, M., et al. (2023) · Ophthalmology Science · doi:10.1016/j.xops.2023.100330 · Cited by 40 · cited 1× · see citing works
“38,40,41,46 To improve the specificity of referral, Mayo Clinic and Stanford adopted an AI-human hybrid workflow (Fig 1, Workflow 4).”
Self-citationWintergerst, M. W. M., Bejan, V., Hartmann, V., Schnorrenberg, M., Bleckwenn, M., Weckbecker, K., & Finger, R. P. (2022) · Ophthalmic Epidemiology · doi:10.1080/09286586.2021.1939886 · Cited by 39 · see citing works
Artificial Intelligence Improves Patient Follow-Up in a Diabetic Retinopathy Screening Program
Dow, E. R., Chen, K. M., Zhao, C., Knapp, A., Phadke, A., Weng, K., Do, D. V., Mahajan, V. B., Mruthyunjaya, P., Leng, T., et al. (2023) · Clinical Ophthalmology · doi:10.2147/opth.s422513 · Cited by 29 · see citing works
Self-citationDeb-Joardar, N., Germain, N., Thuret, G., Manoli, P., Garcin, A.-F., Millot, L., Gavet, Y., Estour, B., & Gain, P. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.051 · Cited by 26 · see citing works
A New Approach to Staging Diabetic Eye Disease
Channa, R., Wolf, R. M., Simo, R., Brigell, M., Fort, P., Curcio, C., Lynch, S., Verbraak, F., Abramoff, M. D., Abramoff, M. D., et al. (2024) · Ophthalmology Science · doi:10.1016/j.xops.2023.100420 · Cited by 26 · see citing works
Mehra, A. A., Softing, A., Guner, M. K., Hodge, D. O., & Barkmeier, A. J. (2022) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2022.08.008 · Cited by 24 · cited 1× · see citing works
“38,40,41,46 To improve the specificity of referral, Mayo Clinic and Stanford adopted an AI-human hybrid workflow (Fig 1, Workflow 4).”
Self-citationMokhashi, N., Grachevskaya, J., Cheng, L., Yu, D., Lu, X., Zhang, Y., & Henderer, J. D. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821999370 · Cited by 23 · cited 1× · see citing works
“38,40,41,46 To improve the specificity of referral, Mayo Clinic and Stanford adopted an AI-human hybrid workflow (Fig 1, Workflow 4).”
Self-citationDeveloping current procedural terminology codes that describe the work performed by machines
Frank, R. A., Jarrin, R., Pritzker, J., Abramoff, M. D., Repka, M. X., Baird, P. D., Marlene Grenon, S., Mahoney, M. R., Mattison, J. E., & Silva, E. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00723-5 · Cited by 23 · cited 1× · see citing works
“20 Based on the claims database in 2023, DR testing has become one of the most widely adopted and fastest-growing AI-aided medical procedures in the United States, only second to coronary artery disease.”
Banaee, T., Ansari-Astaneh, M.-R., Pourreza, H., Faal Hosseini, F., Vatanparast, M., Shoeibi, N., & Jami, V. (2017) · Ophthalmic Epidemiology · doi:10.1080/09286586.2016.1274039 · Cited by 19 · cited 1× · see citing works
“45,49 While multiple studies have shown that diagnostic rates can be increased by a reflexive dilation protocol, 60,61 utilization has been found to be challenging.”
Goldstein, J., Weitzman, D., Lemerond, M., & Jones, A. (2023) · Frontiers in Digital Health · doi:10.3389/fdgth.2023.1004130 · Cited by 16 · see citing works
Wolf, R. M., Channa, R., Lehmann, H. P., Abramoff, M. D., & Liu, T. Y. A. (2024) · Clinical Diabetes · doi:10.2337/cd23-0019 · Cited by 12 · cited 1× · see citing works
“Wolf et al 44 shared additional pointers for successful implementation.”
Self-citationDvey-Aharon, Z., & Huhtinen, P. (2021) · Journal of the Endocrine Society · doi:10.1210/jendso/bvab048.856 · Cited by 8 · see citing works
Shou, B. L., Venkatesh, K., Chen, C., Ghidey, R., Lee, J. H., Wang, J., Channa, R., Wolf, R. M., Abramoff, M. D., & Liu, T. Y. A. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231201654 · Cited by 5 · see citing works
Self-citationALVIN LIU, T. Y., HUANG, J., LEHMANN, H., WOLF, R. M., CHANNA, R., & ABRÀMOFF, M. D. (2023) · Diabetes · doi:10.2337/db23-261-or · Cited by 3 · see citing works
Self-citation
Flagged first, then by citations
1 of the 39 references couldn’t be matched to a known paper.
Research works printed but not linked: 6
- 2023, Fed Regist, 88, 7881
- Huang, 2023, Autonomous artificial intelligence exams are associated with higher adherence to diabetic retinopathy testing in an integrated healthcare system, Invest Ophthalmol Vis Sci, 64, 212
- Najac, 2023, Identifying causes of ungradable fundus photos in an artificial intelligence assisted screening program for diabetic retinopathy, Invest Ophthalmol Vis Sci, 64, 228
- Nelson, 2023, Evaluating Follow-Up metrics in an AI-Assisted telemedicine screening program for diabetic retinopathy in primary care clinics after hiring a patient care navigator, Invest Ophthalmol Vis Sci, 64, 2274
- Leong, 2023, Autonomous artificial intelligence (AI) increases health equity for patients who are more at risk for poor visual outcomes due to diabetic eye disease (DED), Invest Ophthalmol Vis Sci, 64, 243
- Knapp, 2023, Real world outcomes from artificial intelligence to detect diabetic retinopathy in the primary care setting: 12 month experience, Invest Ophthalmol Vis Sci, 64, 252
Cited by
Sorted by citations
Ocular implants and inserts: revolutionizing drug delivery in ophthalmology
Chhoker, D., Yadav, A. K., & Sinha, V. R. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.126248 · Cited by 11 · see citing works
Artificial intelligence in ophthalmology: from innovation to clinical integration
Gurnani, B., & Kaur, K. (2026) · Frontiers in Ophthalmology · doi:10.3389/fopht.2026.1839194 · Cited by 5 · see citing works
Generalizability in OCT Deep Learning—Moving Beyond Single-Disease and Single-Vendor Models
Liu, J. C., & Rajagopal, R. (2026) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2026.0084 · Cited by 2 · see citing works
Self-citationPillai, S. S., & Ashraf, A. P. (2026) · Current Opinion in Pediatrics · doi:10.1097/mop.0000000000001564 · Cited by 2 · see citing works
Emerging Risks of AI-to-AI Interactions in Health Care: Lessons From Moltbook
Athni, T. S. (2026) · Journal of Medical Internet Research · doi:10.2196/96199 · Cited by 4 · see citing works
Miller, M. N., Hsu, D., Tailor, P. D., & Starr, M. R. (2026) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000001225 · Cited by 1 · see citing works
Gil, O., Arad, A., Fogel, M., Vorobichik-Berar, O., Katz, G., Gurevich, R., Tirosh, A., Pelz-Sinvani, N., Moroz, I., Shalem, S., et al. (2026) · British Journal of Ophthalmology · doi:10.1136/bjo-2025-328991 · Cited by 2 · see citing works
Kakaraparthi, V. N., Gannamaneni, V. K., Samuel, P. S., et al. (2026) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-026-01712-0 · Cited by 1 · see citing works
Donocik, W., Sałak, J., Tryczyński, P., Wrona, J., Helbin, P., Gralec, A., Ożga, S., & Spirkowicz, A. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.1(49).2026.5728
Bastos-Carvalho, A., Ware, S. L., Studts, C. R., & Mathenge, W. C. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1863810
Mehr als nur Technik: autonome KI in ophthalmologischer Versorgung
Gronow, T. (2026) · Die Ophthalmologie · doi:10.1007/s00347-026-02466-0
Model-Specific Disruption of Demographic Prediction in Retinal Fundus ImagesPreprint
Majid, I., & Wang, M. (2026) · medRxiv · doi:10.64898/2026.06.23.26356379
Lin, M. Y., Chiang, C. Y. N., Girard, M. J. A., Biousse, V., & Newman, N. J. (2026) · Current Treatment Options in Neurology · doi:10.1007/s11940-026-00875-9
Translating AI Into the Eye Clinic—From Models to Clinical Workflow
Zhang, D., Wang, Y. X., Tham, Y. C., & Wong, T. Y. (2026) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2026.2360
Ophthalmic screening in phakomatoses
Kikani, B., Stanley, S., & Ramasubramanian, A. (2026) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2026.1785180
Иванович, К. Д., Lamotkin, A. I., & Анатольевич, Л. И. (2026) · FARMAKOEKONOMIKA Modern Pharmacoeconomics and Pharmacoepidemiology · doi:10.17749/2070-4909/farmakoekonomika.2026.372
Reporting follow-up budgets for diagnostic and predictive AI
Bair, H., & Djulbegovic, M. (2026) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocag118
Singh, A. K., Pandey, G., Kolipaka, T., & Srivastava, S. (2026) · BioNanoScience · doi:10.1007/s12668-026-02733-z · Cited by 2 · see citing works
Autonomous AI for Diabetic Retinopathy Screening: Evidence, Regulation, and Health-System Fit
Mehta, K., Patel, L., & Shah, M. (2026) · Clinical eHealth · doi:10.1016/j.ceh.2026.07.001
Deobhakta, A. A., Rosen, R. B., Chadha, N., Tsai, J. C., Harris, A., & Pasquale, L. R. (2026) · Current Ophthalmology Reports · doi:10.1007/s40135-026-00355-y
From Black Boxes to Biomarkers: Artificial Intelligence in Surgical Retina
Guo, L. Y., & Ting, D. S. W. (2026) · Ophthalmology Retina · doi:10.1016/j.oret.2026.06.003
Toward autonomous science with agentic artificial intelligence
Guo, L. Y., Ting, D. S. J., Su, X., Aliper, A., Zhavoronkov, A. A., & Ting, D. S. W. (2026) · Cell · doi:10.1016/j.cell.2026.08.052 · Cited by 2 · see citing works
Wong, M. Y. Z., & Ang, M. (2026) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000001246
- Authors
- Teng, C. W., Patel, S. D., Barkmeier, A. J., Liu, T. Y. A., Myung, D., Henderer, J., Liu, J., Hansen, E., & Al-Aswad, L. A.
- Affiliations
- University of Pennsylvania (US)
- Mayo Clinic (US)
- Johns Hopkins University (US)
- Stanford University (US)
- Washington University in St. Louis (US)
- University of Utah (US)
- ORCID
- Venue
- Ophthalmology Science
- Publisher
- Elsevier BV
- Published
- 2026-01
- Volume
- 6
- Issue
- 1
- Pages
- 100935
- ISSN
- 2666-9145 (ISSN-L)
- PMC
- PMC12553049
- OpenAlex
- W4414001469
- Semantic Scholar
- 8211d352251820b3e63b1afe34e6376965ada102
- Cited by
- 23
- References
- 39
- Citations by year
- 2026: 22 · 2025: 1
- FWCI
- 12.53
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Ophthalmology Science (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Research to Prevent Blindness
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Keywords
- artificial intelligence, technology implementation, primary care, diagnostic accuracy, health equity, patient adherence, cost-effectiveness, workflow efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-13.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-13.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review