Cited by 47Retinal Imaging and AnalysisGlaucoma and retinal disordersOphthalmology and Visual Health Research

Evaluation of an AI system for the automated detection of glaucoma from stereoscopic optic disc photographs: the European Optic Disc Assessment Study

Open access
Rogers, Thomas W., Jaccard, Nicolas, Carbonaro, Francis, Lemij, Hans G., Vermeer, Koenraad A., Reus, Nicolaas J., Trikha, Sameer·2019·Eye

Abstract

Objectives To evaluate the performance of a deep learning based Artificial Intelligence (AI) software for detection of glaucoma from stereoscopic optic disc photographs, and to compare this performance to the performance of a large cohort of ophthalmologists and optometrists.Methods A retrospective study evaluating the diagnostic performance of an AI software (Pegasus v1.0, Visulytix Ltd., London UK) and comparing it with that of 243 European ophthalmologists and 208 British optometrists, as determined in previous studies, for the detection of glaucomatous optic neuropathy from 94 scanned stereoscopic photographic slides scanned into digital format.Results Pegasus was able to detect glaucomatous optic neuropathy with an accuracy of 83.4% (95% CI: 77.5-89.2). This is comparable to an average ophthalmologist accuracy of 80.5% (95% CI: 67.2-93.8) and average optometrist accuracy of 80% (95% CI: 67-88) on the same images. In addition, the AI system had an intra-observer agreement (Cohen's Kappa, κ) of 0.74 (95% CI: 0.63-0.85), compared with 0.70 (range: -0.13-1.00; 95% CI: 0.67-0.73) and 0.71 (range: 0.08-1.00) for ophthalmologists and optometrists, respectively. There was no statistically significant difference between the performance of the deep learning system and ophthalmologists or optometrists.Conclusion The AI system obtained a diagnostic performance and repeatability comparable to that of the ophthalmologists and optometrists. We conclude that deep learning based AI systems, such as Pegasus, demonstrate significant promise in the assisted detection of glaucomatous optic neuropathy.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41433-019-0510-3

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Yang GG, Minasyan A, Lacey M, Gordon J, Knoll T. HMGA2 is a reliable immunohistochemical marker for separating melanoma from Nevi. Nature. 2014;94:145A.

Cited by

Sorted by citations

Authors
Rogers, T. W., Jaccard, N., Carbonaro, F., Lemij, H. G., Vermeer, K. A., Reus, N. J., & Trikha, S.
Affiliations
  • Mater Dei Hospital (MT)
  • Rotterdam Eye Hospital (NL)
  • Amphia Ziekenhuis (NL)
  • King's College Hospital NHS Foundation Trust (GB)
Corresponding author
Rogers, Thomas W.
Venue
Eye
Published
2019-07-02
Volume
33
Issue
11
Pages
1791-1797
ISSN
  • 0078-5334 (ISSN-L)
  • 0950-222X
  • 1476-5454
OpenAlex
W2948320234
Cited by
47
References
19
Citations by year
2026: 7 · 2025: 4 · 2024: 4 · 2023: 9 · 2022: 7 · 2021: 11 · 2020: 5
FWCI
3.80
Type
journal article
Language
en
Open access
Locations
  • Eye (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
Keywords
glaucoma detection, glaucomatous optic neuropathy, deep learning, artificial intelligence, automated diagnosis, intraobserver agreement
MeSH terms
Optometrists, Ophthalmologists, Deep Learning, Artificial Intelligence, Clinical Competence, Diagnosis, Computer-Assisted, Europe, False Positive Reactions, Glaucoma, Open-Angle, Humans, Optic Disk, Optic Nerve Diseases, Photography, Predictive Value of Tests, Retrospective Studies, ROC Curve, Sensitivity and Specificity, Reproducibility of Results, Observer Variation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review