A systematic review of simulation-based training tools for technical and non-technical skills in ophthalmology
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To evaluate all simulation models for ophthalmology technical and non-technical skills training and the strength of evidence to support their validity and effectiveness. A systematic search was performed using PubMed and Embase for studies published from inception to 01/07/2019. Studies were analysed according to the training modality: virtual reality; wet-lab; dry-lab models; e-learning. The educational impact of studies was evaluated using Messick’s validity framework and McGaghie’s model of translational outcomes for evaluating effectiveness. One hundred and thirty-one studies were included in this review, with 93 different simulators described. Fifty-three studies were based on virtual reality tools; 47 on wet-lab models; 26 on dry-lab models; 5 on e-learning. Only two studies provided evidence for all five sources of validity assessment. Models with the strongest validity evidence were the Eyesi Surgical, Eyesi Direct Ophthalmoscope and Eye Surgical Skills Assessment Test. Effectiveness ratings for simulator models were mostly limited to level 2 (contained effects) with the exception of the Sophocle vitreoretinal surgery simulator, which was shown at level 3 (downstream effects), and the Eyesi at level 5 (target effects) for cataract surgery. A wide range of models have been described but only the Eyesi has undergone comprehensive investigation. The main weakness is in the poor quality of study design, with a predominance of descriptive reports showing limited validity evidence and few studies investigating the effects of simulation training on patient outcomes. More robust research is needed to enable effective implementation of simulation tools into current training curriculums. 本文旨在评估所有眼科技术与非技术仿真训练设备的优点, 以找到支持其有效性的证据。使用PubMed和Embase从开始研究至2019年7月1日进行文献检索。研究根据训练模式进行分类: 虚拟现实、实际操作实验室、教学实验室以及跟随电子设备学习。使用Messick有效性框架以及转化医学McGaghie模型评估其有效性。本文共纳入131项研究, 涉及 93种不同的模拟训练设备, 其中53项研究基于虚拟现实设备、47项基于实际操作的实验室模型、26项基于教学实验室模型和5项基于电子设备学习。只有2项研究涉及所有5种模拟设备。最有效的模型有Eyesi眼外科系统、Eyesi直接检眼镜和眼外科技能评估测试系统 (Eye Surgical Skills Assessment Test, ESSAT)。模拟训练设备刺激模型的有效性等级大多限制在2级 (包含有效), Sophocle玻璃体视网膜手术模拟设备显示为3级 (下游效应), 以及白内障手术5级 (靶向效应) 。本文针对大多数模型进行了阐述, 对Eyesi进行了深入探讨。本文的局限性在于纳入的研究实验设计质量差, 描述性报告显示有效性证据有限, 很少有研究调查模拟训练对患者结局的影响。因此需要更有力的研究证据, 以便在现有培训课程中有效地应用仿真训练设备。
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meaning and Values in Test Validation: The Science and Ethics of Assessment
Messick, S. (1989) · Educational Researcher · doi:10.3102/0013189x018002005 · Cited by 948
Ophthalmic microsurgical robot and associated virtual environment
Hunter, I. W., Jones, L. A., Sagar, M. A., Lafontaine, S. R., & Hunter, P. J. (1995) · Computers in Biology and Medicine · doi:10.1016/0010-4825(94)00042-o · Cited by 70
Cited by
Nair, A., Mishra, D., Gandhi, R., Gogate, P., Mathur, S., Bhushan, P., Srivastav, T., Singh, H., Sinha, B., & Singh, M. (2020) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1067_20 · Cited by 172
Trends and Innovations of Simulation for Twenty First Century Medical Education
Herrera-Aliaga, E., & Estrada, L. D. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.619769 · Cited by 146
“Simulation has a positive impact on various training areas, such as work in clinical teams (41), improvement in surgical skills (42–47), in ophthalmology (48), in specific health techniques (49–52), critical care (53), pediatrics (54), resuscitation (55), medical emergencies (56), microsurgery (57), anesthesia (58), a…”
BackgroundLing, J., Chan, C.-L., Ho, C.-Y., Gao, X., Tsang, S.-M., Leung, P.-C., Hu, J.-M., & Wong, C.-K. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms231911195 · Cited by 31
Metadata
- Authors
- Lee, R., Raison, N., Lau, W. Y., Aydin, A., Dasgupta, P., Ahmed, K., & Haldar, S.
- Venue
- Eye
- Published
- 2020-03-13
- Volume
- 34
- Issue
- 10
- Pages
- 1737-1759
- ISSN
- 0078-5334 (ISSN-L)
- 0950-222X
- 1476-5454
- OpenAlex
- W3011309374
- Cited by
- 142
- References
- 2
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A systematic review of simulation-based training tools for technical and non-technical skills in ophthalmology. https://app.cochat.ai/papers/10.1038/s41433-020-0832-1
- The paper
- Lee, R., Raison, N., Lau, W. Y., Aydin, A., Dasgupta, P., Ahmed, K., & Haldar, S. (2020). A systematic review of simulation-based training tools for technical and non-technical skills in ophthalmology. Eye. https://doi.org/10.1038/s41433-020-0832-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.