Lifting the bandwidth limit of optical homodyne measurement with broadband parametric amplification
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Homodyne measurement is a corner-stone method of quantum optics that measures the quadratures of light—the quantum optical analog of the canonical position and momentum. Standard homodyne, however, suffers from a severe bandwidth limitation: while the bandwidth of optical states can span many THz, standard homodyne is inherently limited to the electronically accessible MHz-to-GHz range, leaving a dramatic gap between relevant optical phenomena and the measurement capability. We demonstrate a fully parallel optical homodyne measurement across an arbitrary optical bandwidth, effectively lifting this bandwidth limitation completely. Using optical parametric amplification, which amplifies one quadrature while attenuating the other, we measure quadrature squeezing of 1.7 dB simultaneously across 55 THz, using the pump as the only local oscillator. As opposed to standard homodyne, our measurement is robust to detection inefficiency, and was obtained with >50% detection loss. Broadband parametric homodyne opens a wide window for parallel processing of quantum information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scully, M. O., & Zubairy, M. S. (1997) · doi:10.1017/cbo9780511813993 · Cited by 6,589
Quantum information with continuous variables
Braunstein, S. L., & van Loock, P. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.513 · Cited by 3,858
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Unconditional Quantum Teleportation
Furusawa, A., Sørensen, J. L., Braunstein, S. L., Fuchs, C. A., Kimble, H. J., & Polzik, E. S. (1998) · Science · doi:10.1126/science.282.5389.706 · Cited by 3,005
Smithey, D. T., Beck, M., Raymer, M. G., & Faridani, A. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.1244 · Cited by 1,538 · cited 1×
“(5)), and the overall detector response per single photon n(2)0.”
BackgroundBell inequality for position and time
Franson, J. D. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.2205 · Cited by 1,168
Okubo, R., Hirano, M., Zhang, Y., & Hirano, T. (2008) · Optics Letters · doi:10.1364/ol.33.001458 · Cited by 44
Cited by
Kues, M., Reimer, C., Lukens, J. M., Munro, W. J., Weiner, A. M., Moss, D. J., & Morandotti, R. (2019) · Nature Photonics · doi:10.1038/s41566-019-0363-0 · Cited by 697
Toward large-scale fault-tolerant universal photonic quantum computing
Takeda, S., & Furusawa, A. (2019) · APL Photonics · doi:10.1063/1.5100160 · Cited by 234
Time-Domain-Multiplexed Measurement-Based Quantum Operations with 25-MHz Clock Frequency
Asavanant, W., Charoensombutamon, B., Yokoyama, S., Ebihara, T., Nakamura, T., Alexander, R. N., Endo, M., Yoshikawa, J.-I., Menicucci, N. C., Yonezawa, H., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.16.034005 · Cited by 76
Metadata
- Authors
- Shaked, Y., Michael, Y., Vered, R. Z., Bello, L., Rosenbluh, M., & Pe’er, A.
- Venue
- Nature Communications
- Published
- 2018-02-09
- Volume
- 9
- Issue
- 1
- Pages
- 609-609
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2806759896
- Cited by
- 122
- References
- 7
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lifting the bandwidth limit of optical homodyne measurement with broadband parametric amplification. https://app.cochat.ai/papers/10.1038/s41467-018-03083-5
- The paper
- Shaked, Y., Michael, Y., Vered, R. Z., Bello, L., Rosenbluh, M., & Pe’er, A. (2018). Lifting the bandwidth limit of optical homodyne measurement with broadband parametric amplification. Nature Communications. https://doi.org/10.1038/s41467-018-03083-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.