Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.

High performance planar germanium-on-silicon single-photon avalanche diode detectors

Vines, Peter, Kuzmenko, Kateryna, Kirdoda, Jarosław, Dumas, Derek C. S., Mirza, Muhammad M., Millar, Ross W., Paul, Douglas J., Buller, Gerald S.·2019·Nature Communications

Abstract

Single-photon detection has emerged as a method of choice for ultra-sensitive measurements of picosecond optical transients. In the short-wave infrared, semiconductor-based single-photon detectors typically exhibit relatively poor performance compared with all-silicon devices operating at shorter wavelengths. Here we show a new generation of planar germanium-on-silicon (Ge-on-Si) single-photon avalanche diode (SPAD) detectors for short-wave infrared operation. This planar geometry has enabled a significant step-change in performance, demonstrating single-photon detection efficiency of 38% at 125 K at a wavelength of 1310 nm, and a fifty-fold improvement in noise equivalent power compared with optimised mesa geometry SPADs. In comparison with InGaAs/InP devices, Ge-on-Si SPADs exhibit considerably reduced afterpulsing effects. These results, utilising the inexpensive Ge-on-Si platform, provide a route towards large arrays of efficient, high data rate Ge-on-Si SPADs for use in eye-safe automotive LIDAR and future quantum technology applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-019-08830-w

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Ge-on-Si single-photon avalanche diode (SPAD) structure. Cross-section of a planar Ge-on-Si SPAD showing the Ge top contact and absorption layers, the Si charge sheet, multiplication and bottom contact layers, metallisation and the planarization, passivation and anti-reflection (AR) coating
Fig. 1 Ge-on-Si single-photon avalanche diode (SPAD) structure. Cross-section of a planar Ge-on-Si SPAD showing the Ge top contact and absorption layers, the Si charge sheet, multiplication and bottom contact layers, metallisation and the planarization, passivation and anti-reflection (AR) coatingCC BY · PubMed Central
Fig. 2 Single-photon avalanche diode modelling and current-voltage behaviour. a Electric field profile at 5% excess bias for the planar single-photon avalanche diode (SPAD). b Electric field profile at 5% excess bias for the mesa etched SPAD. c Current-voltage measurements on 100 µm diameter planar (blue line) and mesa etched (green line) structures at a temperature of 100 K under dark conditions. d Current-voltage measurements on a 100 µm diameter planar device at a temperature of 78 K. The graph shows dark current (blue line) and photocurrent when illuminated with a 1310 nm laser (red line). Punchthrough is evident at 20 V
Fig. 2 Single-photon avalanche diode modelling and current-voltage behaviour. a Electric field profile at 5% excess bias for the planar single-photon avalanche diode (SPAD). b Electric field profile at 5% excess bias for the mesa etched SPAD. c Current-voltage measurements on 100 µm diameter planar (blue line) and mesa etched (green line) structures at a temperature of 100 K under dark conditions. d Current-voltage measurements on a 100 µm diameter planar device at a temperature of 78 K. The graph shows dark current (blue line) and photocurrent when illuminated with a 1310 nm laser (red line). Punchthrough is evident at 20 VCC BY · PubMed Central
Fig. 3 Ge-on-Si single-photon avalanche diode (SPAD) performance. Single-photon detection efficiency (SPDE) and dark count rate (DCR) as a function of excess bias for a 100 µm diameter SPAD at temperatures of a 78 K, b 100 K and c 125 K. The measurements were taken using the time-correlated single-photon counting (TCSPC) technique with a 50 ns electrical gate applied to the detector to bias it above avalanche breakdown. For the SPDE measurements the gate was synchronised with the arrival of the 1310 nm wavelength attenuated laser pulse. The detector was gated at a repetition rate of 1 kHz
Fig. 3 Ge-on-Si single-photon avalanche diode (SPAD) performance. Single-photon detection efficiency (SPDE) and dark count rate (DCR) as a function of excess bias for a 100 µm diameter SPAD at temperatures of a 78 K, b 100 K and c 125 K. The measurements were taken using the time-correlated single-photon counting (TCSPC) technique with a 50 ns electrical gate applied to the detector to bias it above avalanche breakdown. For the SPDE measurements the gate was synchronised with the arrival of the 1310 nm wavelength attenuated laser pulse. The detector was gated at a repetition rate of 1 kHzCC BY · PubMed Central
Fig. 4 Ge-on-Si single-photon avalanche diode (SPAD) jitter. Timing histogram for a 100 µm diameter SPAD at an excess bias of 5.5% and a temperature of 78 K with incident radiation at λ = 1310 nm. The jitter full-width-at-half maximum (FWHM) was 310 ps
Fig. 4 Ge-on-Si single-photon avalanche diode (SPAD) jitter. Timing histogram for a 100 µm diameter SPAD at an excess bias of 5.5% and a temperature of 78 K with incident radiation at λ = 1310 nm. The jitter full-width-at-half maximum (FWHM) was 310 psCC BY · PubMed Central
Fig. 5 Single-photon detection efficiency (SPDE) as a function of wavelength. a Normalised SPDE as a function of incident wavelength for a 100 µm single-photon avalanche diode (SPAD) at temperatures of 125 K (black squares), 150 K (red circles) and 175 K (blue triangles). b Experimental (squares) and theoretical (line) Ge cut-off wavelength as a function of temperature. c Estimated cut-off wavelength and fitting for a Ge-on-Si SPAD with a 2-µm-thick Ge absorption region. The red lines in b and c indicate the temperature required to reach a cut-off wavelength of 1550 nm
Fig. 5 Single-photon detection efficiency (SPDE) as a function of wavelength. a Normalised SPDE as a function of incident wavelength for a 100 µm single-photon avalanche diode (SPAD) at temperatures of 125 K (black squares), 150 K (red circles) and 175 K (blue triangles). b Experimental (squares) and theoretical (line) Ge cut-off wavelength as a function of temperature. c Estimated cut-off wavelength and fitting for a Ge-on-Si SPAD with a 2-µm-thick Ge absorption region. The red lines in b and c indicate the temperature required to reach a cut-off wavelength of 1550 nmCC BY · PubMed Central
Fig. 6 Single-photon avalanche diode afterpulsing. a Afterpulsing probability as a function of gate delay time for a 100 µm diameter Ge-on-Si single-photon avalanche detector (SPAD) (open squares) compared to a 25 µm diameter commercially available InGaAs/InP SPAD (closed squares) when measured at λ = 1310 nm and operated at a single-photon detection efficiency (SPDE) of 17% and a temperature of 125 K. b Activation energy for the Ge-on-Si SPAD as a function of excess bias. The activation energies were acquired by fitting Arrhenius plots to the afterpulsing lifetime time constants. c The band structure at the Ge-Si heterointerface at 125 K showing the trapped defect states from dislocations (dashed lines) and the Γ valley (red line), L valley (blue line), Δ valley (black line), Light Hole (LH) band (grey line), Heavy Hole (HH) band (green line) and Split-Off (SO) band (yellow line)
Fig. 6 Single-photon avalanche diode afterpulsing. a Afterpulsing probability as a function of gate delay time for a 100 µm diameter Ge-on-Si single-photon avalanche detector (SPAD) (open squares) compared to a 25 µm diameter commercially available InGaAs/InP SPAD (closed squares) when measured at λ = 1310 nm and operated at a single-photon detection efficiency (SPDE) of 17% and a temperature of 125 K. b Activation energy for the Ge-on-Si SPAD as a function of excess bias. The activation energies were acquired by fitting Arrhenius plots to the afterpulsing lifetime time constants. c The band structure at the Ge-Si heterointerface at 125 K showing the trapped defect states from dislocations (dashed lines) and the Γ valley (red line), L valley (blue line), Δ valley (black line), Light Hole (LH) band (grey line), Heavy Hole (HH) band (green line) and Split-Off (SO) band (yellow line)CC BY · PubMed Central
Fig. 7 Single-photon characterisation setup. Schematic diagram of the experimental setup used for time-correlated single-photon counting (TCSPC) characterisation. The black lines denote electrical connections, the red solid lines denote optical fibre connections and the red dotted line denotes the free-space optical connection. The laser spot was directed onto the optical area of the SPAD using a broadband imaging system (not shown). The cryostat housing the SPAD has been removed for clarity
Fig. 7 Single-photon characterisation setup. Schematic diagram of the experimental setup used for time-correlated single-photon counting (TCSPC) characterisation. The black lines denote electrical connections, the red solid lines denote optical fibre connections and the red dotted line denotes the free-space optical connection. The laser spot was directed onto the optical area of the SPAD using a broadband imaging system (not shown). The cryostat housing the SPAD has been removed for clarityCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 58 references

Cited by

See all 195

Metadata

Authors
Vines, P., Kuzmenko, K., Kirdoda, J., Dumas, D. C. S., Mirza, M. M., Millar, R. W., Paul, D. J., & Buller, G. S.
Venue
Nature Communications
Published
2019-03-06
Volume
10
Issue
1
ISSN
2041-1723
Cited by
195
References
58
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High performance planar germanium-on-silicon single-photon avalanche diode detectors. https://app.cochat.ai/papers/10.1038/s41467-019-08830-w
The paper
Vines, P., Kuzmenko, K., Kirdoda, J., Dumas, D. C. S., Mirza, M. M., Millar, R. W., Paul, D. J., & Buller, G. S. (2019). High performance planar germanium-on-silicon single-photon avalanche diode detectors. Nature Communications. https://doi.org/10.1038/s41467-019-08830-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.