Cryopolymerization enables anisotropic polyaniline hybrid hydrogels with superelasticity and highly deformation-tolerant electrochemical energy storage
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
The development of energy storage devices that can endure large and complex deformations is central to emerging wearable electronics. Hydrogels made from conducting polymers give rise to a promising integration of high conductivity and versatility in processing. However, the emergence of conducting polymer hydrogels with a desirable network structure cannot be readily achieved using conventional polymerization methods. Here we present a cryopolymerization strategy for preparing an intrinsically stretchable, compressible and bendable anisotropic polyvinyl alcohol/polyaniline hydrogel with a complete recovery of 100% stretching strain, 50% compressing strain and fully bending. Due to its high mechanical strength, superelastic properties and bi-continuous phase structure, the as-obtained anisotropic polyvinyl alcohol/polyaniline hydrogel can work as a stretching/compressing/bending electrode, maintaining its stable output under complex deformations for an all-solid-state supercapacitor. In particular, it achieves an extremely high energy density of 27.5 W h kg−1, which is among that of state-of-the-art stretchable supercapacitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible Energy‐Storage Devices: Design Consideration and Recent Progress
Wang, X., Lu, X., Liu, B., Chen, D., Tong, Y., & Shen, G. (2014) · Advanced Materials · doi:10.1002/adma.201400910 · Cited by 1,385
Xu, J., Wang, K., Zu, S.-Z., Han, B.-H., & Wei, Z. (2010) · ACS Nano · doi:10.1021/nn1006539 · Cited by 1,383
Self-citationHierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
Kayser, L. V., & Lipomi, D. J. (2019) · Advanced Materials · doi:10.1002/adma.201806133 · Cited by 1,186
Coaxial wet-spun yarn supercapacitors for high-energy density and safe wearable electronics
Kou, L., Huang, T., Zheng, B., Han, Y., Zhao, X., Gopalsamy, K., Sun, H., & Gao, C. (2014) · Nature Communications · doi:10.1038/ncomms4754 · Cited by 1,134
Eftekhari, A., Li, L., & Yang, Y. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.02.054 · Cited by 926
Self-citationBeidaghi, M., & Wang, C. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201201292 · Cited by 812
A self-healable and highly stretchable supercapacitor based on a dual crosslinked polyelectrolyte
Huang, Y., Zhong, M., Huang, Y., Zhu, M., Pei, Z., Wang, Z., Xue, Q., Xie, X., & Zhi, C. (2015) · Nature Communications · doi:10.1038/ncomms10310 · Cited by 742
Shi, Y., Pan, L., Liu, B., Wang, Y., Cui, Y., Bao, Z., & Yu, G. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta00484a · Cited by 699
Self-citationA kirigami approach to engineering elasticity in nanocomposites through patterned defects
Shyu, T. C., Damasceno, P. F., Dodd, P. M., Lamoureux, A., Xu, L., Shlian, M., Shtein, M., Glotzer, S. C., & Kotov, N. A. (2015) · Nature Materials · doi:10.1038/nmat4327 · Cited by 681
Cited by
Zhao, Z., Xia, K., Hou, Y., Zhang, Q., Ye, Z., & Lu, J. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00800e · Cited by 490
Cyclic stability of supercapacitors: materials, energy storage mechanism, test methods, and device
Wu, Q., He, T., Zhang, Y., Zhang, J., Wang, Z., Liu, Y., Zhao, L., Wu, Y., & Ran, F. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta06815f · Cited by 449
Self-citationMultifunctional conductive hydrogels and their applications as smart wearable devices
Chen, Z., Chen, Y., Hedenqvist, M. S., Chen, C., Cai, C., Li, H., Liu, H., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb02929g · Cited by 323
Cheng, T., Zhang, Y., Wang, S., Chen, Y., Gao, S., Wang, F., Lai, W., & Huang, W. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202101303 · Cited by 308
Self-citationRoy, A., Zenker, S., Jain, S., Afshari, R., Oz, Y., Zheng, Y., & Annabi, N. (2024) · Advanced Materials · doi:10.1002/adma.202404225 · Cited by 278
Mechanically Strong and Multifunctional Hybrid Hydrogels with Ultrahigh Electrical Conductivity
Zhou, Q., Lyu, J., Wang, G., Robertson, M., Qiang, Z., Sun, B., Ye, C., & Zhu, M. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104536 · Cited by 247
Temperature-Responsive Ionic Conductive Hydrogel for Strain and Temperature Sensors
Pang, Q., Hu, H., Zhang, H., Qiao, B., & Ma, L. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c06952 · Cited by 242
Yu, X., Zhang, H., Wang, Y., Fan, X., Li, Z., Zhang, X., & Liu, T. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204366 · Cited by 239
Self-citationHybrid assembly of polymeric nanofiber network for robust and electronically conductive hydrogels
He, H., Li, H., Pu, A., Li, W., Ban, K., & Xu, L. (2023) · Nature Communications · doi:10.1038/s41467-023-36438-8 · Cited by 236
Chen, Z., Liu, J., Chen, Y., Zheng, X., Liu, H., & Li, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c16719 · Cited by 228
Construction methods and biomedical applications of PVA-based hydrogels
Zhong, Y., Lin, Q., Yu, H., Shao, L., Cui, X., Pang, Q., Zhu, Y., & Hou, R. (2024) · Frontiers in Chemistry · doi:10.3389/fchem.2024.1376799 · Cited by 207
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Self-citationMredha, M. T. I., & Jeon, I. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100870 · Cited by 183
Karimzadeh, Z., Mahmoudpour, M., Rahimpour, E., & Jouyban, A. (2022) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2022.102705 · Cited by 178
Hierarchical architecture of MXene/PANI hybrid electrode for advanced asymmetric supercapacitors
Li, Y., Kamdem, P., & Jin, X.-J. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2020.156608 · Cited by 177
Luo, W., Wei, Y., Zhuang, Z., Lin, Z., Li, X., Hou, C., Li, T., & Ma, Y. (2022) · Electrochimica Acta · doi:10.1016/j.electacta.2022.139871 · Cited by 173
Metadata
- Authors
- Li, L., Zhang, Y., Lu, H., Wang, Y., Xu, J., Zhu, J., Zhang, C., & Liu, T.
- Venue
- Nature Communications
- Published
- 2020-01-07
- Volume
- 11
- Issue
- 1
- Pages
- 62-62
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2998883194
- Cited by
- 354
- References
- 61
- FWCI
- 32.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.