Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.

A Highly Stretchable, Conductive, and Transparent Bioadhesive Hydrogel as a Flexible Sensor for Enhanced Real‐Time Human Health Monitoring

Open access
Roy, Arpita, Zenker, Shea, Jain, Saumya, Afshari, Ronak, Oz, Yavuz, Zheng, Yuting, Annabi, Nasim·2024·Advanced Materials

Abstract

Real‐time continuous monitoring of non‐cognitive markers is crucial for the early detection and management of chronic conditions. Current diagnostic methods are often invasive and not suitable for at‐home monitoring. An elastic, adhesive, and biodegradable hydrogel‐based wearable sensor with superior accuracy and durability for monitoring real‐time human health is developed. Employing a supramolecular engineering strategy, a pseudo‐slide‐ring hydrogel is synthesized by combining polyacrylamide (pAAm), β‐cyclodextrin (β‐CD), and poly 2‐(acryloyloxy)ethyltrimethylammonium chloride (AETAc) bio ionic liquid (Bio‐IL). This novel approach decouples conflicting mechano–chemical effects arising from different molecular building blocks and provides a balance of mechanical toughness (1.1 × 10 6 Jm−3), flexibility, conductivity (≈0.29 S m−1), and tissue adhesion (≈27 kPa), along with rapid self‐healing and remarkable stretchability (≈3000%). Unlike traditional hydrogels, the one‐pot synthesis avoids chemical crosslinkers and metallic nanofillers, reducing cytotoxicity. While the pAAm provides mechanical strength, the formation of the pseudo‐slide‐ring structure ensures high stretchability and flexibility. Combining pAAm with β‐CD and pAETAc enhances biocompatibility and biodegradability, as confirmed by in vitro and in vivo studies. The hydrogel also offers transparency, passive‐cooling, ultraviolet (UV)‐shielding, and 3D printability, enhancing its practicality for everyday use. The engineered sensor demonstratesimproved efficiency, stability, and sensitivity in motion/haptic sensing, advancing real‐time human healthcare monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202404225

Cites

133 of 133 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 133 references

Metadata

Authors
Roy, A., Zenker, S., Jain, S., Afshari, R., Oz, Y., Zheng, Y., & Annabi, N.
Venue
Advanced Materials
Publisher
Wiley
Published
2024-07-06
Volume
36
Issue
35
Pages
e2404225-e2404225
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W4399887213
Cited by
278
References
133
FWCI
29.20
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Highly Stretchable, Conductive, and Transparent Bioadhesive Hydrogel as a Flexible Sensor for Enhanced Real‐Time Human Health Monitoring. https://app.cochat.ai/papers/10.1002/adma.202404225
The paper
Roy, A., Zenker, S., Jain, S., Afshari, R., Oz, Y., Zheng, Y., & Annabi, N. (2024). A Highly Stretchable, Conductive, and Transparent Bioadhesive Hydrogel as a Flexible Sensor for Enhanced Real‐Time Human Health Monitoring. Advanced Materials. https://doi.org/10.1002/adma.202404225

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.