Low-dose phase retrieval of biological specimens using cryo-electron ptychography
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Cryo-electron microscopy is an essential tool for high-resolution structural studies of biological systems. This method relies on the use of phase contrast imaging at high defocus to improve information transfer at low spatial frequencies at the expense of higher spatial frequencies. Here we demonstrate that electron ptychography can recover the phase of the specimen with continuous information transfer across a wide range of the spatial frequency spectrum, with improved transfer at lower spatial frequencies, and as such is more efficient for phase recovery than conventional phase contrast imaging. We further show that the method can be used to study frozen-hydrated specimens of rotavirus double-layered particles and HIV-1 virus-like particles under low-dose conditions (5.7 e/Å 2) and heterogeneous objects in an Adenovirus-infected cell over large fields of view (1.14 × 1.14 μm), thus making it suitable for studies of many biologically important structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Model for the structure of bacteriorhodopsin based on high-resolution electron cryo-microscopy
Henderson, R., Baldwin, J. M., Ceska, T. A., Zemlin, F., Beckmann, E., & Downing, K. H. (1990) · Journal of Molecular Biology · doi:10.1016/s0022-2836(05)80271-2 · Cited by 2,980
Three-dimensional model of purple membrane obtained by electron microscopy
Henderson, R., & Unwin, P. N. T. (1975) · Nature · doi:10.1038/257028a0 · Cited by 2,282
Li, X., Mooney, P., Zheng, S., Booth, C. R., Braunfeld, M. B., Gubbens, S., Agard, D. A., & Cheng, Y. (2013) · Nature Methods · doi:10.1038/nmeth.2472 · Cited by 1,818
Structure of the TRPV1 ion channel determined by electron cryo-microscopy
Liao, M., Cao, E., Julius, D., & Cheng, Y. (2013) · Nature · doi:10.1038/nature12822 · Cited by 1,686
An improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496
Cryo-electron microscopy of viruses
Adrian, M., Dubochet, J., Lepault, J., & McDowall, A. W. (1984) · Nature · doi:10.1038/308032a0 · Cited by 1,342
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Henderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194
How cryo-EM is revolutionizing structural biology
Bai, X.-C., McMullan, G., & Scheres, S. H. W. (2015) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2014.10.005 · Cited by 936
Fourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927
Metadata
- Authors
- Zhou, L., Song, J., Kim, J. S., Pei, X., Huang, C., Boyce, M., Mendonça, L., Clare, D., Siebert, A., Allen, C. S., Liberti, E., Stuart, D., Pan, X., Nellist, P. D., Zhang, P., Kirkland, A. I., & Wang, P.
- Venue
- Nature Communications
- Published
- 2020-06-02
- Volume
- 11
- Issue
- 1
- Pages
- 2773-2773
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3032336952
- Cited by
- 163
- References
- 30
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-dose phase retrieval of biological specimens using cryo-electron ptychography. https://app.cochat.ai/papers/10.1038/s41467-020-16391-6
- The paper
- Zhou, L., Song, J., Kim, J. S., Pei, X., Huang, C., Boyce, M., Mendonça, L., Clare, D., Siebert, A., Allen, C. S., Liberti, E., Stuart, D., Pan, X., Nellist, P. D., Zhang, P., Kirkland, A. I., & Wang, P. (2020). Low-dose phase retrieval of biological specimens using cryo-electron ptychography. Nature Communications. https://doi.org/10.1038/s41467-020-16391-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.