Raman image-activated cell sorting
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
The advent of image-activated cell sorting and imaging-based cell picking has advanced our knowledge and exploitation of biological systems in the last decade. Unfortunately, they generally rely on fluorescent labeling for cellular phenotyping, an indirect measure of the molecular landscape in the cell, which has critical limitations. Here we demonstrate Raman image-activated cell sorting by directly probing chemically specific intracellular molecular vibrations via ultrafast multicolor stimulated Raman scattering (SRS) microscopy for cellular phenotyping. Specifically, the technology enables real-time SRS-image-based sorting of single live cells with a throughput of up to ~100 events per second without the need for fluorescent labeling. To show the broad utility of the technology, we show its applicability to diverse cell types and sizes. The technology is highly versatile and holds promise for numerous applications that are previously difficult or undesirable with fluorescence-based technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Haslam, D. W., & James, W. P. T. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67483-1 · Cited by 3,757
Hematopoietic Stem-Cell Transplantation
Copelan, E. A. (2006) · New England Journal of Medicine · doi:10.1056/nejmra052638 · Cited by 2,522
Efficacy and Toxicity Management of 19-28z CAR T Cell Therapy in B Cell Acute Lymphoblastic Leukemia
Davila, M. L., Riviere, I., Wang, X., Bartido, S., Park, J., Curran, K., Chung, S. S., Stefanski, J., Borquez-Ojeda, O., Olszewska, M., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008226 · Cited by 2,476
An outlook on microalgal biofuels
Wijffels, R. H., & Barbosa, M. J. (2010) · Science · doi:10.1126/science.1189003 · Cited by 1,886
Naive and Primed Pluripotent States
Nichols, J., & Smith, A. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.05.015 · Cited by 1,859
Quantitative phase imaging in biomedicine
Park, Y., Depeursinge, C., & Popescu, G. (2018) · Nature Photonics · doi:10.1038/s41566-018-0253-x · Cited by 1,802
Autologous Induced Stem-Cell–Derived Retinal Cells for Macular Degeneration
Mandai, M., Watanabe, A., Kurimoto, Y., Hirami, Y., Morinaga, C., Daimon, T., Fujihara, M., Akimaru, H., Sakai, N., Shibata, Y., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1608368 · Cited by 1,509
Self-citationAngiogenesis and Inflammation in Peritoneal Dialysis: The Role of Adipocytes
Shi, J., Yu, M., & Sheng, M. (2017) · Kidney and Blood Pressure Research · doi:10.1159/000476017 · Cited by 1,403
Stable-isotope probing as a tool in microbial ecology
Radajewski, S., Ineson, P., Parekh, N. R., & Murrell, J. C. (2000) · Nature · doi:10.1038/35001054 · Cited by 1,252
Cited by
Raman Spectroscopy for Chemical Biology Research
Dodo, K., Fujita, K., & Sodeoka, M. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c05359 · Cited by 329
Recent Advances in Microfluidic Technology for Bioanalysis and Diagnostics
Berlanda, S. F., Breitfeld, M., Dietsche, C. L., & Dittrich, P. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04366 · Cited by 305
Honrado, C., Bisegna, P., Swami, N. S., & Caselli, F. (2021) · Lab on a Chip · doi:10.1039/d0lc00840k · Cited by 222
Rahaman, M. T., Pranta, A. D., Repon, M. R., Ahmed, M. S., & Islam, T. (2024) · Journal of Open Innovation: Technology, Market, and Complexity · doi:10.1016/j.joitmc.2024.100280 · Cited by 169
Machine learning for microfluidic design and control
McIntyre, D., Lashkaripour, A., Fordyce, P., & Densmore, D. (2022) · Lab on a Chip · doi:10.1039/d2lc00254j · Cited by 166
Dual-frequency impedance assays for intracellular components in microalgal cells
Tang, T., Liu, X., Yuan, Y., Kiya, R., Shen, Y., Zhang, T., Suzuki, K., Tanaka, Y., Li, M., Hosokawa, Y., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc00721a · Cited by 26
Self-citationLi, X., Chen, J., Yang, Y., Cai, H., Ao, Z., Xing, Y., Li, K., Yang, K., Guan, W., Friend, J., et al. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00916-4 · Cited by 17
“…a wide range of compatibility with various interfacial sensing technologies, which can improve the performance and functionality, such as enzyme-linked immunosorbent assay (ELISA) 49 , surface plasmon resonance (SPR) 50 , and Raman sensing 51 , greatly expanding the range of practical applications.”
Recent Developments (After 2020) in Flow Cytometry Worldwide and Within China
Du, X., Chen, X., Gao, C., Wang, J., Huo, X., & Chen, J. (2025) · Biosensors · doi:10.3390/bios15030156 · Cited by 10
“For instance, Goda et al. reported high-speed Raman imaging based on a unique laser source with a switchangle wavelength and pulse-pair resolution, enabling a throughput of up to ~100 cells/s (see Figure 2a) [37].”
Metadata
- Authors
- Nitta, N., Iino, T., Isozaki, A., Yamagishi, M., Kitahama, Y., Sakuma, S., Suzuki, Y., Tezuka, H., Oikawa, M., Arai, F., Asai, T., Deng, D., Fukuzawa, H., Hase, M., Hasunuma, T., Hayakawa, T., Hiraki, K., Hiramatsu, K., Hoshino, Y., Inaba, M., Inoue, Y., Ito, T., Kajikawa, M., Karakawa, H., Kasai, Y., Kato, Y., Kobayashi, H., Lei, C., Matsusaka, S., Mikami, H., Nakagawa, A., Numata, K., Ota, T., Sekiya, T., Shiba, K., Shirasaki, Y., Suzuki, N., Tanaka, S., Ueno, S., Watarai, H., Yamano, T., Yazawa, M., Yonamine, Y., Di Carlo, D., Hosokawa, Y., Uemura, S., Sugimura, T., Ozeki, Y., & Goda, K.
- Venue
- Nature Communications
- Published
- 2020-07-10
- Volume
- 11
- Issue
- 1
- Pages
- 3452-3452
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3041069161
- Cited by
- 205
- References
- 74
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.