Artificial intelligence for the detection of COVID-19 pneumonia on chest CT using multinational datasets

Open access

Abstract

Chest CT is emerging as a valuable diagnostic tool for clinical management of COVID-19 associated lung disease. Artificial intelligence (AI) has the potential to aid in rapid evaluation of CT scans for differentiation of COVID-19 findings from other clinical entities. Here we show that a series of deep learning algorithms, trained in a diverse multinational cohort of 1280 patients to localize parietal pleura/lung parenchyma followed by classification of COVID-19 pneumonia, can achieve up to 90.8% accuracy, with 84% sensitivity and 93% specificity, as evaluated in an independent test set (not included in training and validation) of 1337 patients. Normal controls included chest CTs from oncology, emergency, and pneumonia-related indications. The false positive rate in 140 patients with laboratory confirmed other (non COVID-19) pneumonias was 10%. AI-based algorithms can readily identify CT scans with COVID-19 associated pneumonia, as well as distinguish non-COVID related pneumonias with high specificity in diverse patient populations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-020-17971-2

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 3D classification workflow. All CT images under lung segmentation for localization to chest cavity region. Following cropping to lung region, two methods were considered for differentiation of COVID-19 from other clinical entities. a Full 3D Model resampled the cropped lung region of CT to a fixed size (192 × 192 × 64 voxels) for input to algorithm. b Hybrid CT resampled the cropped lung region of CT to fixed resolution (1mm × 1mm × 5mm) and sampled multiple 3D regions (192 × 192 × 32) for input to algorithm. At training, 6 regions/patient were used. At inference 15 regions/patient were used and results were averaged to produce final probability of COVID-19.
Fig. 1 3D classification workflow. All CT images under lung segmentation for localization to chest cavity region. Following cropping to lung region, two methods were considered for differentiation of COVID-19 from other clinical entities. a Full 3D Model resampled the cropped lung region of CT to a fixed size (192 × 192 × 64 voxels) for input to algorithm. b Hybrid CT resampled the cropped lung region of CT to fixed resolution (1mm × 1mm × 5mm) and sampled multiple 3D regions (192 × 192 × 32) for input to algorithm. At training, 6 regions/patient were used. At inference 15 regions/patient were used and results were averaged to produce final probability of COVID-19.CC BY · PubMed Central
Fig. 2 Model performance. Receiver operating characteristic (ROC) curve for 3D and hybrid 3D classification models. Both experimental conditions are shown, with highlighted area to zoom in at upper left area of the curve. Solid lines represent original training design, dotted lines indicate independent testing population design.
Fig. 2 Model performance. Receiver operating characteristic (ROC) curve for 3D and hybrid 3D classification models. Both experimental conditions are shown, with highlighted area to zoom in at upper left area of the curve. Solid lines represent original training design, dotted lines indicate independent testing population design.CC BY · PubMed Central
Fig. 3 Grad-CAM* resultant saliency maps for five representative COVID-19 patients from testing set. All images are of correctly predicted positive by 3D model. Within the heatmap, areas of red indicate activation of the algorithm related with COVID-19 prediction. a, b Images and (f, g) associated maps from Hubei, China cohort. c Image and (h) associated map from Tokyo, Japan cohort. d Image and (i) associated map from an advanced case in Milan, Italy Center #1. Note activation in non-consolidating areas for prediction of COVID-19, indicating specific features independent of pneumonia-related consolidation are learned. e Image and (j) associated map of an advanced case in Milan, Italy Center #2. Note: case (e) represents an unseen testing center from training/validation centers. *footnote: Grad-CAM images are produced from preprocessed input data, including cropping to lung region and resizing to fixed dimension, which may result in visible changes to anatomic aspect ratio.
Fig. 3 Grad-CAM* resultant saliency maps for five representative COVID-19 patients from testing set. All images are of correctly predicted positive by 3D model. Within the heatmap, areas of red indicate activation of the algorithm related with COVID-19 prediction. a, b Images and (f, g) associated maps from Hubei, China cohort. c Image and (h) associated map from Tokyo, Japan cohort. d Image and (i) associated map from an advanced case in Milan, Italy Center #1. Note activation in non-consolidating areas for prediction of COVID-19, indicating specific features independent of pneumonia-related consolidation are learned. e Image and (j) associated map of an advanced case in Milan, Italy Center #2. Note: case (e) represents an unseen testing center from training/validation centers. *footnote: Grad-CAM images are produced from preprocessed input data, including cropping to lung region and resizing to fixed dimension, which may result in visible changes to anatomic aspect ratio.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 588

Metadata

Authors
Harmon, S. A., Sanford, T. H., Xu, S., Turkbey, E. B., Roth, H., Xu, Z., Yang, D., Myronenko, A., Anderson, V., Amalou, A., Blain, M., Kassin, M., Long, D., Varble, N., Walker, S. M., Bagci, U., Ierardi, A. M., Stellato, E., Plensich, G. G., Franceschelli, G., Girlando, C., Irmici, G., Labella, D., Hammoud, D., Malayeri, A., Jones, E., Summers, R. M., Choyke, P. L., Xu, D., Flores, M., Tamura, K., Obinata, H., Mori, H., Patella, F., Cariati, M., Carrafiello, G., An, P., Wood, B. J., & Turkbey, B.
Affiliations
  • National Institutes of Health (US)
  • State University of New York (US)
  • Nvidia (United States) (US)
  • Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT)
  • Ospedale San Paolo (IT)
  • University of Milan (IT)
  • Self-Defense Forces Central Hospital (JP)
  • Hubei University of Medicine (CN)
Corresponding author
Wood, Bradford J.
Venue
Nature Communications
Published
2020-08-14
Volume
11
Issue
1
Pages
4080-4080
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3049757379
Cited by
587
References
28
Citations by year
2026: 28 · 2025: 40 · 2024: 64 · 2023: 113 · 2022: 141 · 2021: 181 · 2020: 19
FWCI
55.37
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • U.S. Department of Health and Human Services (Task Order No. 75N91019F00129, No. 75N91019D00024, Contract No. 75N91019D00024, 75N91019D00024)
  • Nvidia
  • Société Française de Radiologie
  • National Institutes of Health (Contract No.75N91019D00024, 75N91019D00024, COVID-19, 75N91019F00129)
  • National Cancer Institute (Contract No: 75N91019D00024, 75N91019D00024, 75N91019F00129, CL040015, ZIDBC011242)
  • NIH Clinical Center (ZIACL040015)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
COVID-19 pneumonia, chest CT, deep learning, artificial intelligence, pneumonia detection, lung parenchyma, diagnostic accuracy, cross-population generalizability, image classification
MeSH terms
Betacoronavirus, Deep Learning, COVID-19, SARS-CoV-2, COVID-19 Testing, Adolescent, Adult, Aged, Aged, 80 and over, Algorithms, Artificial Intelligence, Child, Child, Preschool, Female, Humans, Lung, Male, Middle Aged, Pneumonia, Viral, Radiographic Image Interpretation, Computer-Assisted, Tomography, X-Ray Computed, Coronavirus Infections, Clinical Laboratory Techniques, Imaging, Three-Dimensional, Young Adult, Pandemics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial intelligence for the detection of COVID-19 pneumonia on chest CT using multinational datasets. https://app.cochat.ai/papers/10.1038/s41467-020-17971-2
The paper
Harmon, S. A., Sanford, T. H., Xu, S., Turkbey, E. B., Roth, H., Xu, Z., Yang, D., Myronenko, A., Anderson, V., Amalou, A., Blain, M., Kassin, M., Long, D., Varble, N., Walker, S. M., Bagci, U., Ierardi, A. M., Stellato, E., Plensich, G. G., . . . Turkbey, B. (2020). Artificial intelligence for the detection of COVID-19 pneumonia on chest CT using multinational datasets. Nature Communications. https://doi.org/10.1038/s41467-020-17971-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.