AutoSpill is a principled framework that simplifies the analysis of multichromatic flow cytometry data

Open access
Roca, Carlos P., Burton, Oliver T., Gergelits, Václav, Prezzemolo, Teresa, Whyte, Carly E., Halpert, Richard, Kreft, Łukasz, Collier, James, Botzki, Alexander, Spidlen, Josef, Humblet-Baron, Stéphanie, Liston, Adrian · 2021 · Nature Communications
Cited by 56

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Compensating in flow cytometry is an unavoidable challenge in the data analysis of fluorescence-based flow cytometry. Even the advent of spectral cytometry cannot circumvent the spillover problem, with spectral unmixing an intrinsic part of such systems. The calculation of spillover coefficients from single-color controls has remained essentially unchanged since its inception, and is increasingly limited in its ability to deal with high-parameter flow cytometry. Here, we present AutoSpill, an alternative method for calculating spillover coefficients. The approach combines automated gating of cells, calculation of an initial spillover matrix based on robust linear regression, and iterative refinement to reduce error. Moreover, autofluorescence can be compensated out, by processing it as an endogenous dye in an unstained control. AutoSpill uses single-color controls and is compatible with common flow cytometry software. AutoSpill allows simpler and more robust workflows, while reducing the magnitude of compensation errors in high-parameter flow cytometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-021-23126-8

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 56

Metadata

Authors
Roca, C. P., Burton, O. T., Gergelits, V., Prezzemolo, T., Whyte, C. E., Halpert, R., Kreft, Ł., Collier, J., Botzki, A., Spidlen, J., Humblet-Baron, S., & Liston, A.
Venue
Nature Communications
Published
2021-05-17
Volume
12
Issue
1
Pages
2890-2890
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3162301887
Cited by
56
References
4
FWCI
3.53
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AutoSpill is a principled framework that simplifies the analysis of multichromatic flow cytometry data. https://app.cochat.ai/papers/10.1038/s41467-021-23126-8
The paper
Roca, C. P., Burton, O. T., Gergelits, V., Prezzemolo, T., Whyte, C. E., Halpert, R., Kreft, Ł., Collier, J., Botzki, A., Spidlen, J., Humblet-Baron, S., & Liston, A. (2021). AutoSpill is a principled framework that simplifies the analysis of multichromatic flow cytometry data. Nature Communications. https://doi.org/10.1038/s41467-021-23126-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.