The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Probing the Na metal solid electrolyte interphase via cryo-transmission electron microscopy
Open accessAbstract
Cryogenic transmission electron microscopy (cryo-TEM) is a valuable tool recently proposed to investigate battery electrodes. Despite being employed for Li-based battery materials, cryo-TEM measurements for Na-based electrochemical energy storage systems are not commonly reported. In particular, elucidating the chemical and morphological behavior of the Na-metal electrode in contact with a non-aqueous liquid electrolyte solution could provide useful insights that may lead to a better understanding of metal cells during operation. Here, using cryo-TEM, we investigate the effect of fluoroethylene carbonate (FEC) additive on the solid electrolyte interphase (SEI) structure of a Na-metal electrode. Without FEC, the NaPF 6-containing carbonate-based electrolyte reacts with the metal electrode to produce an unstable SEI, rich in Na 2 CO 3 and Na 3 PO 4, which constantly consumes the sodium reservoir of the cell during cycling. When FEC is used, the Na-metal electrode forms a multilayer SEI structure comprising an outer NaF-rich amorphous phase and an inner Na 3 PO 4 phase. This layered structure stabilizes the SEI and prevents further reactions between the electrolyte and the Na metal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Opportunities and challenges for a sustainable energy future
Chu, S., & Majumdar, A. (2012) · Nature · doi:10.1038/nature11475 · Cited by 12,550
Atomic structure of sensitive battery materials and interfaces revealed by cryo–electron microscopy
Li, Y., Li, Y., Pei, A., Yan, K., Sun, Y., Wu, C.-L., Joubert, L.-M., Chin, R., Koh, A. L., Yu, Y., et al. (2017) · Science · doi:10.1126/science.aam6014 · Cited by 1,547
Cited by
Fan, X., Zhong, C., Liu, J., Ding, J., Deng, Y., Han, X., Zhang, L., Hu, W., Wilkinson, D. P., & Zhang, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00196 · Cited by 347
Self-citation
Metadata
- Authors
- Han, B., Zou, Y., Zhang, Z., Yang, X., Shi, X., Meng, H., Wang, H., Xu, K., Deng, Y., & Gu, M.
- Venue
- Nature Communications
- Published
- 2021-05-24
- Volume
- 12
- Issue
- 1
- Pages
- 3066-3066
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3164331806
- Cited by
- 229
- References
- 2
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Probing the Na metal solid electrolyte interphase via cryo-transmission electron microscopy. https://app.cochat.ai/papers/10.1038/s41467-021-23368-6
- The paper
- Han, B., Zou, Y., Zhang, Z., Yang, X., Shi, X., Meng, H., Wang, H., Xu, K., Deng, Y., & Gu, M. (2021). Probing the Na metal solid electrolyte interphase via cryo-transmission electron microscopy. Nature Communications. https://doi.org/10.1038/s41467-021-23368-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.