Exclusive and ultrasensitive detection of formaldehyde at room temperature using a flexible and monolithic chemiresistive sensor
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Formaldehyde, a probable carcinogen, is a ubiquitous indoor pollutant, but its highly selective detection has been a long-standing challenge. Herein, a chemiresistive sensor that can detect ppb-level formaldehyde in an exclusive manner at room temperature is designed. The TiO 2 sensor exhibits under UV illumination highly selective detection of formaldehyde and ethanol with negligible cross-responses to other indoor pollutants. The coating of a mixed matrix membrane (MMM) composed of zeolitic imidazole framework (ZIF-7) nanoparticles and polymers on TiO 2 sensing films removed ethanol interference completely by molecular sieving, enabling an ultrahigh selectivity (response ratio > 50) and response (resistance ratio > 1,100) to 5 ppm formaldehyde at room temperature. Furthermore, a monolithic and flexible sensor is fabricated successfully using a TiO 2 film sandwiched between a flexible polyethylene terephthalate substrate and MMM overlayer. Our work provides a strategy to achieve exclusive selectivity and high response to formaldehyde, demonstrating the promising potential of flexible gas sensors for indoor air monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Throughput Synthesis of Zeolitic Imidazolate Frameworks and Application to CO 2 Capture
Banerjee, R., Phan, A., Wang, B., Knobler, C., Furukawa, H., O'Keeffe, M., & Yaghi, O. M. (2008) · Science · doi:10.1126/science.1152516 · Cited by 4,205
Explaining the Enhanced Photocatalytic Activity of Degussa P25 Mixed-Phase TiO 2 Using EPR
Hurum, D. C., Agrios, A. G., Gray, K. A., Rajh, T., & Thurnauer, M. C. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp0273934 · Cited by 2,015
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Kolmakov, A., Klenov, D. O., Lilach, Y., Stemmer, S., & Moskovits, M. (2005) · Nano Letters · doi:10.1021/nl050082v · Cited by 1,385
Metal and Metal Oxide Nanoparticles in Chemiresistors: Does the Nanoscale Matter?
Franke, M. E., Koplin, T., & Simon, U. (2005) · Small · doi:10.1002/smll.200500261 · Cited by 1,376
Metal and Metal Oxide Nanoparticles in Chemiresistors: Does the Nanoscale Matter?
Franke, M. E., Koplin, T., & Simon, U. (2006) · Small · doi:10.1002/smll.200690010 · Cited by 1,056
Performance studies of mixed matrix membranes for gas separation: A review
Aroon, M. A., Ismail, A. F., Matsuura, T., & Montazer-Rahmati, M. M. (2010) · Separation and Purification Technology · doi:10.1016/j.seppur.2010.08.023 · Cited by 852
Gücüyener, C., van den Bergh, J., Gascon, J., & Kapteijn, F. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1089765 · Cited by 737
Yao, M., Tang, W., Wang, G., Nath, B., & Xu, G. (2016) · Advanced Materials · doi:10.1002/adma.201506457 · Cited by 641
Tian, H., Fan, H., Li, M., & Ma, L. (2016) · ACS Sensors · doi:10.1021/acssensors.5b00236 · Cited by 464
Cited by
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
MOF‐Based Chemiresistive Gas Sensors: Toward New Functionalities
Jo, Y., Jo, Y. K., Lee, J., Jang, H. W., Hwang, I., & Yoo, D. J. (2023) · Advanced Materials · doi:10.1002/adma.202206842 · Cited by 410
Self-citationTi3C2Tx MXene-Based Flexible Piezoresistive Physical Sensors
Wang, Y., Yue, Y., Cheng, F., Cheng, Y., Ge, B., Liu, N., & Gao, Y. (2022) · ACS Nano · doi:10.1021/acsnano.1c09925 · Cited by 406
Recent Progress on Flexible Room-Temperature Gas Sensors Based on Metal Oxide Semiconductor
Ou, L.-X., Liu, M.-Y., Zhu, L.-Y., Zhang, D. W., & Lu, H.-L. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00956-9 · Cited by 402
Advances in flexible sensors for intelligent perception system enhanced by artificial intelligence
Niu, H., Yin, F., Kim, E., Wang, W., Yoon, D., Wang, C., Liang, J., Li, Y., & Kim, N. (2023) · InfoMat · doi:10.1002/inf2.12412 · Cited by 165
The Challenges and Opportunities for TiO2 Nanostructures in Gas Sensing
Zhao, J., Wang, H., Cai, Y., Zhao, J., Gao, Z., & Song, Y.-Y. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00137 · Cited by 164
Essential role of lattice oxygen in hydrogen sensing reaction
Li, J., Si, W., Shi, L., Gao, R., Li, Q., An, W., Zhao, Z., Zhang, L., Bai, N., Zou, X., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47078-x · Cited by 163
“32 and 33).”
Metadata
- Authors
- Jo, Y. K., Jeong, S.-Y., Moon, Y. K., Jo, Y.-M., Yoon, J.-W., & Lee, J.-H.
- Venue
- Nature Communications
- Published
- 2021-08-16
- Volume
- 12
- Issue
- 1
- Pages
- 4955-4955
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3193885413
- Cited by
- 218
- References
- 35
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.