Determination of X-ray detection limit and applications in perovskite X-ray detectors
Open accessAbstract
X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Cited by
Buried Interface Modification in Perovskite Solar Cells: A Materials Perspective
Gao, Z., Wang, Y., & Choy, W. C. H. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202104030 · Cited by 271
Zhao, X., Li, Z., Wang, S., Song, Y., Hong, E., Yan, T., Meng, G., & Fang, X. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202500039 · Cited by 18
Metadata
- Authors
- Pan, L., Shrestha, S., Taylor, N., Nie, W., & Cao, L. R.
- Venue
- Nature Communications
- Published
- 2021-09-06
- Volume
- 12
- Issue
- 1
- Pages
- 5258-5258
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3167508804
- Cited by
- 185
- References
- 1
- FWCI
- 19.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of X-ray detection limit and applications in perovskite X-ray detectors. https://app.cochat.ai/papers/10.1038/s41467-021-25648-7
- The paper
- Pan, L., Shrestha, S., Taylor, N., Nie, W., & Cao, L. R. (2021). Determination of X-ray detection limit and applications in perovskite X-ray detectors. Nature Communications. https://doi.org/10.1038/s41467-021-25648-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.