Determination of X-ray detection limit and applications in perovskite X-ray detectors
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/5174 · Cited by 8,161
U1 snRNP regulates cancer cell migration and invasion in vitro
Oh, J.-M., Venters, C. C., Di, C., Pinto, A. M., Wan, L., Younis, I., Cai, Z., Arai, C., So, B. R., Duan, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13993-7 · Cited by 7,157
Fundamentals of Biostatistics.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-4-873 · Cited by 4,575
Limits for qualitative detection and quantitative determination. Application to radiochemistry
Currie, L. A. (1968) · Analytical Chemistry · doi:10.1021/ac60259a007 · Cited by 4,553
Limit of detection. A closer look at the IUPAC definition
Long, G. L., & Winefordner, J. D. (1983) · Analytical Chemistry · doi:10.1021/ac00258a001 · Cited by 2,162
Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals
Wei, H., Fang, Y., Mulligan, P., Chuirazzi, W., Fang, H.-H., Wang, C., Ecker, B. R., Gao, Y., Loi, M. A., Cao, L., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.41 · Cited by 1,877
Self-citationCurrie, L. A. (1995) · Pure and Applied Chemistry · doi:10.1351/pac199567101699 · Cited by 1,703
Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit
Pan, W., Wu, H., Luo, J., Deng, Z., Ge, C., Chen, C., Jiang, X., Yin, W.-J., Niu, G., Zhu, L., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0012-4 · Cited by 1,416
Printable organometallic perovskite enables large-area, low-dose X-ray imaging
Kim, Y. C., Kim, K. H., Son, D.-Y., Jeong, D.-N., Seo, J.-Y., Choi, Y. S., Han, I. T., Lee, S. Y., & Park, N.-G. (2017) · Nature · doi:10.1038/nature24032 · Cited by 1,206
Long, G. L., Voigtman, E. G., Kosinski, M. A., & Winefordner, J. D. (1983) · Analytical Chemistry · doi:10.1021/ac00259a060 · Cited by 1,120
Halide lead perovskites for ionizing radiation detection
Wei, H., & Huang, J. (2019) · Nature Communications · doi:10.1038/s41467-019-08981-w · Cited by 976
Wei, W., Zhang, Y., Xu, Q., Wei, H., Fang, Y., Wang, Q., Deng, Y., Li, T., Gruverman, A., Cao, L., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.43 · Cited by 814
Self-citationWei, H., DeSantis, D., Wei, W., Deng, Y., Guo, D., Savenije, T. J., Cao, L., & Huang, J. (2017) · Nature Materials · doi:10.1038/nmat4927 · Cited by 660
Self-citationShrestha, S., Fischer, R., Matt, G. J., Feldner, P., Michel, T., Osvet, A., Levchuk, I., Merle, B., Golkar, S., Chen, H., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.94 · Cited by 646
Self-citationZhuang, R., Wang, X., Ma, W., Wu, Y., Chen, X., Tang, L., Zhu, H., Liu, J., Wu, L., Zhou, W., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0466-7 · Cited by 630
Zhang, Y., Liu, Y., Xu, Z., Ye, H., Yang, Z., You, J., Liu, M., He, Y., Kanatzidis, M. G., & Liu, S. (2020) · Nature Communications · doi:10.1038/s41467-020-16034-w · Cited by 545
X-ray sensitivity of photoconductors: application to stabilized a-Se
Kasap, S. O. (2000) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/33/21/326 · Cited by 545 · cited 3×
“(1) and (2) (named as Detection Limit (DL) equations thereafter in this paper) are a well-established model in statistical hypothesis testing theory36.”
BackgroundStabilizing lithium metal using ionic liquids for long-lived batteries
Basile, A., Bhatt, A. I., & O’Mullane, A. P. (2016) · Nature Communications · doi:10.1038/ncomms11794 · Cited by 467
Perovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays
Zhao, J., Zhao, L., Deng, Y., Xiao, X., Ni, Z., Xu, S., & Huang, J. (2020) · Nature Photonics · doi:10.1038/s41566-020-0678-x · Cited by 408
Liu, Y., Zhang, Y., Yang, Z., Yang, D., Ren, X., Pang, L., & Liu, S. (. (2016) · Advanced Materials · doi:10.1002/adma.201601995 · Cited by 386
Flexible, Printable Soft‐X‐Ray Detectors Based on All‐Inorganic Perovskite Quantum Dots
Liu, J., Shabbir, B., Wang, C., Wan, T., Ou, Q., Yu, P., Tadich, A., Jiao, X., Chu, D., Qi, D., et al. (2019) · Advanced Materials · doi:10.1002/adma.201901644 · Cited by 375
Hot‐Pressed CsPbBr3 Quasi‐Monocrystalline Film for Sensitive Direct X‐ray Detection
Pan, W., Yang, B., Niu, G., Xue, K., Du, X., Yin, L., Zhang, M., Wu, H., Miao, X., & Tang, J. (2019) · Advanced Materials · doi:10.1002/adma.201904405 · Cited by 346
An encrusting kleptoparasite-host interaction from the early Cambrian
Zhang, Z., Strotz, L. C., Topper, T. P., Chen, F., Chen, Y., Liang, Y., Zhang, Z., Skovsted, C. B., & Brock, G. A. (2020) · Nature Communications · doi:10.1038/s41467-020-16332-3 · Cited by 287
Xia, M., Yuan, J., Niu, G., Du, X., Yin, L., Pan, W., Luo, J., Li, Z., Zhao, H., Xue, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910648 · Cited by 272
A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes
Tsai, H., Liu, F., Shrestha, S., Fernando, K., Tretiak, S., Scott, B. L., Vo, D. T., Strzalka, J. W., & Nie, W. (2020) · Science Advances · doi:10.1126/sciadv.aay0815 · Cited by 269
Self-citationTie, S., Zhao, W., Xin, D., Zhang, M., Long, J., Chen, Q., Zheng, X., Zhu, J., & Zhang, W. (2020) · Advanced Materials · doi:10.1002/adma.202001981 · Cited by 249
Direct observation of imploded core heating via fast electrons with super-penetration scheme
Gong, T., Habara, H., Sumioka, K., Yoshimoto, M., Hayashi, Y., Kawazu, S., Otsuki, T., Matsumoto, T., Minami, T., Abe, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13574-8 · Cited by 199
High-sensitivity X-ray detectors based on solution-grown caesium lead bromide single crystals
Zhang, H., Wang, F., Lu, Y., Sun, Q., Xu, Y., Zhang, B.-B., Jie, W., & Kanatzidis, M. G. (2020) · Journal of Materials Chemistry C · doi:10.1039/c9tc05490a · Cited by 171
Direct X-ray photoconversion in flexible organic thin film devices operated below 1 V
Basiricò, L., Ciavatti, A., Cramer, T., Cosseddu, P., Bonfiglio, A., & Fraboni, B. (2016) · Nature Communications · doi:10.1038/ncomms13063 · Cited by 170
A micron-scale laminar MAPbBr3 single crystal for an efficient and stable perovskite solar cell
Rao, H.-S., Chen, B.-X., Wang, X.-D., Kuang, D.-B., & Su, C.-Y. (2017) · Chemical Communications · doi:10.1039/c7cc02447a · Cited by 170
Hu, M., Jia, S., Liu, Y., Cui, J. Y., Zhang, Y., Su, H., Cao, S., Mo, L., Chu, D., Zhao, G., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b23158 · Cited by 160
Perovskite semiconductors for direct X-ray detection and imaging
Su, Y., Ma, W., & Yang, Y. (2020) · Journal of Semiconductors · doi:10.1088/1674-4926/41/5/051204 · Cited by 135
Pan, L., Feng, Y., Huang, J., & Cao, L. R. (2020) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2020.3018101 · Cited by 64
Self-citationFirst human imaging with MARS photon-counting CT
Panta, R. K., Butler, A. P. H., Butler, P. H., de Ruiter, N. J. A., Bell, S. T., Walsh, M. F., Doesburg, R. M. N., Chernoglazov, A. I., Goulter, B. P., Carbonez, P., et al. (2018) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2018.8824513 · Cited by 32 · cited 1×
“(3), which is another form of the DL equations.”
Background
Cited by
Buried Interface Modification in Perovskite Solar Cells: A Materials Perspective
Gao, Z., Wang, Y., & Choy, W. C. H. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202104030 · Cited by 271
Zhao, X., Li, Z., Wang, S., Song, Y., Hong, E., Yan, T., Meng, G., & Fang, X. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202500039 · Cited by 18
Metadata
- Authors
- Pan, L., Shrestha, S., Taylor, N., Nie, W., & Cao, L. R.
- Venue
- Nature Communications
- Published
- 2021-09-06
- Volume
- 12
- Issue
- 1
- Pages
- 5258-5258
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3167508804
- Cited by
- 185
- References
- 35
- FWCI
- 19.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.