CoChat

Operando monitoring of ion activities in aqueous batteries with plasmonic fiber-optic sensors

Open access
Wang, Runlin, Zhang, Haozhe, Liu, Qiyu, Liu, Fu, Han, Xile, Liu, Xiaoqing, Li, Kaiwei, Xiao, Gaozhi, Albert, Jacques, Lu, Xihong, Guo, Tuan · 2022 · Nature Communications
Cited by 179

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Abstract

Understanding ion transport kinetics and electrolyte-electrode interactions at electrode surfaces of batteries in operation is essential to determine their performance and state of health. However, it remains a challenging task to capture in real time the details of surface-localized and rapid ion transport at the microscale. To address this, a promising approach based on an optical fiber plasmonic sensor capable of being inserted near the electrode surface of a working battery to monitor its electrochemical kinetics without disturbing its operation is demonstrated using aqueous Zn-ion batteries as an example. The miniature and chemically inert sensor detects perturbations of surface plasmon waves propagating on its surface to rapidly screen localized electrochemical events on a sub-μm-scale thickness adjacent to the electrode interface. A stable and reproducible correlation between the real-time ion insertions over charge-discharge cycles and the optical plasmon response has been observed and quantified. This new operando measurement tool will provide crucial additional capabilities to battery monitoring methods and help guide the design of better batteries with improved electro-chemistries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-022-28267-y

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 179

Metadata

Authors
Wang, R., Zhang, H., Liu, Q., Liu, F., Han, X., Liu, X., Li, K., Xiao, G., Albert, J., Lu, X., & Guo, T.
Venue
Nature Communications
Published
2022-01-27
Volume
13
Issue
1
Pages
547-547
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4210530892
Cited by
179
References
50
FWCI
10.64
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Operando monitoring of ion activities in aqueous batteries with plasmonic fiber-optic sensors. https://app.cochat.ai/papers/10.1038/s41467-022-28267-y
The paper
Wang, R., Zhang, H., Liu, Q., Liu, F., Han, X., Liu, X., Li, K., Xiao, G., Albert, J., Lu, X., & Guo, T. (2022). Operando monitoring of ion activities in aqueous batteries with plasmonic fiber-optic sensors. Nature Communications. https://doi.org/10.1038/s41467-022-28267-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.