Energy comparison of sequential and integrated CO2 capture and electrochemical conversion
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Integrating carbon dioxide (CO 2 ) electrolysis with CO 2 capture provides exciting new opportunities for energy reductions by simultaneously removing the energy-demanding regeneration step in CO 2 capture and avoiding critical issues faced by CO 2 gas-fed electrolysers. However, understanding the potential energy advantages of an integrated process is not straightforward due to the interconnected processes which require knowledge of both capture and electrochemical conversion processes. Here, we identify the upper limits of the integrated process from an energy perspective by comparing the working principles and performance of integrated and sequential approaches. Our high-level energy analyses unveil that an integrated electrolyser must show similar performance to the gas-fed electrolyser to ensure an energy benefit of up to 44% versus the sequential route. However, such energy benefits diminish if future gas-fed electrolysers resolve the CO 2 utilisation issue and if an integrated electrolyser shows lower conversion efficiencies than the gas-fed system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress and perspectives of electrochemical CO2 reduction on copper in aqueous electrolyte
Nitopi, S., Bertheussen, E., Scott, S. B., Liu, X., Engstfeld, A. K., Horch, S., Seger, B., Stephens, I. E. L., Chan, K., Hahn, C., et al. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00705 · Cited by 5,223
What would it take for renewably powered electrosynthesis to displace petrochemical processes?
De Luna, P., Hahn, C., Higgins, D., Jaffer, S. A., Jaramillo, T. F., & Sargent, E. H. (2019) · Science · doi:10.1126/science.aav3506 · Cited by 3,052
A Process for Capturing CO2 from the Atmosphere
Keith, D. W., Holmes, G., St. Angelo, D., & Heidel, K. (2018) · Joule · doi:10.1016/j.joule.2018.05.006 · Cited by 1,910
CO 2 electrolysis to multicarbon products at activities greater than 1 A cm −2
García de Arquer, F. P., Dinh, C.-T., Ozden, A., Wicks, J., McCallum, C., Kirmani, A. R., Nam, D.-H., Gabardo, C., Seifitokaldani, A., Wang, X., et al. (2020) · Science · doi:10.1126/science.aay4217 · Cited by 1,517
CO 2 electrolysis to multicarbon products in strong acid
Huang, J. E., Li, F., Ozden, A., Sedighian Rasouli, A., García de Arquer, F. P., Liu, S., Zhang, S., Luo, M., Wang, X., Lum, Y., et al. (2021) · Science · doi:10.1126/science.abg6582 · Cited by 1,359
GILLIAM, R., GRAYDON, J., KIRK, D., & THORPE, S. (2007) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2006.10.062 · Cited by 702
Riboldi, L., & Bolland, O. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.03.1385 · Cited by 256
Metadata
- Authors
- Li, M., Irtem, E., Iglesias van Montfort, H.-P., Abdinejad, M., & Burdyny, T.
- Venue
- Nature Communications
- Published
- 2022-09-14
- Volume
- 13
- Issue
- 1
- Pages
- 5398-5398
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4295786012
- Cited by
- 160
- References
- 7
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.