Design of stretchable and self-powered sensing device for portable and remote trace biomarkers detection
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Timely and remote biomarker detection is highly desired in personalized medicine and health protection but presents great challenges in the devices reported so far. Here, we present a cost-effective, flexible and self-powered sensing device for H 2 S biomarker analysis in various application scenarios based on the structure of galvanic cells. The sensing mechanism is attributed to the change in electrode potential resulting from the chemical adsorption of gas molecules on the electrode surfaces. Intrinsically stretchable organohydrogels are used as solid-state electrolytes to enable stable and long-term operation of devices under stretching deformation or in various environments. The resulting open-circuit sensing device exhibits high sensitivity, low detection limit, and excellent selectivity for H 2 S. Its application in the non-invasive halitosis diagnosis and identification of meat spoilage is demonstrated, emerging great commercial value in portable medical electronics and food security. A wireless sensory system has also been developed for remote H 2 S monitoring with the participation of Bluetooth and cloud technologies. This work breaks through the shortcomings in the traditional chemiresistive sensors, offering a direction and theoretical foundation for designing wearable sensors catering to other stimulus detection requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, C., Yang, W., & Parr, R. G. (1988) · Physical Review B · doi:10.1103/physrevb.37.785 · Cited by 100,874 · cited 1×
“…adsorption energy between H 2 S and Zn atoms is only − 0.042 eV, whichismainlyphysicaladsorption,andtheweakchemicaladsorption that rarely exists can also lead to quite small changes in the Zn electrode potential, thus causing the weak response of the Ag-encapsulated sensor mentioned above 48 – 51 .”
InfluentialDensity-functional exchange-energy approximation with correct asymptotic behavior
Becke, A. D. (1988) · Physical Review A · doi:10.1103/physreva.38.3098 · Cited by 53,711
Highly stretchable and tough hydrogels
Sun, J.-Y., Zhao, X., Illeperuma, W. R. K., Chaudhuri, O., Oh, K. H., Mooney, D. J., Vlassak, J. J., & Suo, Z. (2012) · Nature · doi:10.1038/nature11409 · Cited by 5,481
Energy-adjusted a b i n i t i o pseudopotentials for the first row transition elements
Dolg, M., Wedig, U., Stoll, H., & Preuss, H. (1987) · The Journal of Chemical Physics · doi:10.1063/1.452288 · Cited by 3,543
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Shrivastava, A., & Gupta, V. (2011) · Chronicles of Young Scientists · doi:10.4103/2229-5186.79345 · Cited by 3,205
Designing Cell-Compatible Hydrogels for Biomedical Applications
Seliktar, D. (2012) · Science · doi:10.1126/science.1214804 · Cited by 1,923 · cited 2×
“Being composed of water and three-dimensional polymeric networks, hydrogels have been shown to be one of the most potential sensing components in wearable applications in recent years, thanks to their intrinsic stretchability, transparency, biocompatibility, and stimulus-responsiveness 26 – 30 .”
Highly stretchable, transparent ionic touch panel
Kim, C.-C., Lee, H.-H., Oh, K. H., & Sun, J.-Y. (2016) · Science · doi:10.1126/science.aaf8810 · Cited by 1,047 · cited 1×
“27).”
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918 · cited 1×
“Currently, methods for accurate detection of H 2 S in medical diagnosis include gas chromatography/mass spectrometry 10 , ion chromatography 7 , etc.”
MXenes stretch hydrogel sensor performance to new limits
Zhang, Y.-Z., Lee, K. H., Anjum, D. H., Sougrat, R., Jiang, Q., Kim, H., & Alshareef, H. N. (2018) · Science Advances · doi:10.1126/sciadv.aat0098 · Cited by 783
Cited by
Smart Gas Sensors: Recent Developments and Future Prospective
Zong, B., Wu, S., Yang, Y., Li, Q., Tao, T., & Mao, S. (2025) · Nano-Micro Letters · doi:10.1007/s40820-024-01543-w · Cited by 282
Roy, A., Zenker, S., Jain, S., Afshari, R., Oz, Y., Zheng, Y., & Annabi, N. (2024) · Advanced Materials · doi:10.1002/adma.202404225 · Cited by 278
Shi, Y., Guan, Y., Liu, M., Kang, X., Tian, Y., Deng, W., Yu, P., Ning, C., Zhou, L., Fu, R., et al. (2024) · ACS Nano · doi:10.1021/acsnano.3c11578 · Cited by 235
A review on flexible wearables – Recent developments in non-invasive continuous health monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2024) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2023.114993 · Cited by 196
Precisely manipulating polymer chain interactions for multifunctional hydrogels
Guo, S., Zhang, S., Li, H., Liu, S., Koh, J. J., Zhou, M., Sun, Z., Liu, Y., Qu, H., Yu, Z., et al. (2025) · Matter · doi:10.1016/j.matt.2024.06.024 · Cited by 179
Self-citationTordi, P., Ridi, F., Samorì, P., & Bonini, M. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202416390 · Cited by 175
Wang, W., Yao, D., Wang, H., Ding, Q., Luo, Y., Ding, H., Yu, J., Zhang, H., Tao, K., Zhang, S., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202316339 · Cited by 162
Self-citation
Metadata
- Authors
- Huang, W., Ding, Q., Wang, H., Wu, Z., Luo, Y., Shi, W., Yang, L., Liang, Y., Liu, C., & Wu, J.
- Venue
- Nature Communications
- Published
- 2023-08-26
- Volume
- 14
- Issue
- 1
- Pages
- 5221-5221
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4386191750
- Cited by
- 166
- References
- 46
- FWCI
- 12.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.