Estimation of joint torque in dynamic activities using wearable A-mode ultrasound
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




![Fig. 5 Knee torque estimation during treadmill and outdoor locomotion. A Illustration of participants performing various walking and running tasks on an instrumented treadmill with RF thickness measured with SETs and joint kinematics measured with wireless IMUs. B Example estimated knee torque during the stance phase (left column) and corresponding ground truth (right column) for treadmill locomotion at various speeds (0.75, 1.25, 1.75 m s−1 walking and 2.50, 3.00 m s−1 running) and slopes [+10% (top row), 0% (middle row), −10% (bottom row)] from a representative participant. Lines and shaded regions represent mean ± SD across the steps within each condition. C RMSEs for different locomotion types across all participants (n = 5). Student’s two-tailed t tests: walk vs run (p = 0.873). D RMSEs for different slope levels across all participants (n = 5). One-way ANOVA: no significant main effect (p = 0.965, F2,8 = 0.036). For C and D, each box bounds the IQR divided by the median with whiskers extending up to 1.5*IQR. Each dot represents the RMSE for one participant. E Photograph of a participant performing outdoor locomotion with a backpack containing the A-mode ultrasound electronics. Placements of SETs and IMUs remained unchanged compared to the treadmill test. F Knee torque estimation at different speeds during level ground outdoor locomotion. Lines and shaded regions represent mean ± SD (n = 15 steps). G Knee torque estimation during comfortable-speed downhill and uphill walking and running. Lines and shaded regions represent mean ± SD (n = 15 steps).](https://figures.cochat.ai/paper-figures/518caa39bfd442ed9aa4116c03e72a57/estimation-of-joint-torque-in-dynamic-activities-using-wearable-a-mode-figure-5.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Functional and clinical significance of skeletal muscle architecture
Lieber, R. L., & Frid�n, J. (2000) · Muscle & Nerve · doi:10.1002/1097-4598(200011)23:11<1647::aid-mus1>3.0.co;2-m · Cited by 1,254
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Model-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Recovery and Performance in Sport: Consensus Statement
Kellmann, M., Bertollo, M., Bosquet, L., Brink, M., Coutts, A. J., Duffield, R., Erlacher, D., Halson, S. L., Hecksteden, A., Heidari, J., et al. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2017-0759 · Cited by 824
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R. D., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 816
Anatomical Data for Analyzing Human Motion
Plagenhoef, S., Evans, F. G., & Abdelnour, T. (1983) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1983.10605290 · Cited by 647
Bioadhesive ultrasound for long-term continuous imaging of diverse organs
Wang, C., Chen, X., Wang, L., Makihata, M., Liu, H.-C., Zhou, T., & Zhao, X. (2022) · Science · doi:10.1126/science.abo2542 · Cited by 599
Narici, M. V., Binzoni, T., Hiltbrand, E., Fasel, J., Terrier, F., & Cerretelli, P. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021685 · Cited by 555
Disselhorst-Klug, C., Schmitz-Rode, T., & Rau, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.003 · Cited by 414
Variable gearing in pennate muscles
Azizi, E., Brainerd, E. L., & Roberts, T. J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709212105 · Cited by 396
Key Concepts in Model Selection: Performance and Generalizability
Forster, M. R. (2000) · Journal of Mathematical Psychology · doi:10.1006/jmps.1999.1284 · Cited by 384
Relevance of in vivo force measurements to human biomechanics
Komi, P. V. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90038-5 · Cited by 374
A fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
Lin, M., Zhang, Z., Gao, X., Bian, Y., Wu, R. S., Park, G., Lou, Z., Zhang, Z., Xu, X., Chen, X., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01800-0 · Cited by 364
Current interventions in the management of knee osteoarthritis
Bhatia, D., Bejarano, T., & Novo, M. (2013) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/0975-7406.106561 · Cited by 271
Correlation of Torque and Elbow Injury in Professional Baseball Pitchers
Anz, A. W., Bushnell, B. D., Griffin, L. P., Noonan, T. J., Torry, M. R., & Hawkins, R. J. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546510363402 · Cited by 264
Modeling Overuse Injuries in Sport as a Mechanical Fatigue Phenomenon
Edwards, W. B. (2018) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000163 · Cited by 262
Farris, D. J., & Lichtwark, G. A. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.02.016 · Cited by 236
In vivo behavior of the human soleus muscle with increasing walking and running speeds
Lai, A., Lichtwark, G. A., Schache, A. G., Lin, Y.-C., Brown, N. A. T., & Pandy, M. G. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00128.2015 · Cited by 199
Behavior of human muscle fascicles during shortening and lengthening contractions in vivo
Reeves, N. D., & Narici, M. V. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01046.2002 · Cited by 198
Considerations and Practical Options for Measuring Muscle Strength: A Narrative Review
Bohannon, R. W. (2019) · BioMed Research International · doi:10.1155/2019/8194537 · Cited by 187
Gauging force by tapping tendons
Martin, J. A., Brandon, S. C. E., Keuler, E. M., Hermus, J. R., Ehlers, A. C., Segalman, D. J., Allen, M. S., & Thelen, D. G. (2018) · Nature Communications · doi:10.1038/s41467-018-03797-6 · Cited by 186
EMG normalization to study muscle activation in cycling
Rouffet, D., & Hautier, C. A. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.03.008 · Cited by 182
Lower extremity muscle activities during cycling are influenced by load and frequency
Baum, B. S., & Li, L. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00110-4 · Cited by 174
Interpreting muscle function from EMG: lessons learned from direct measurements of muscle force
Roberts, T. J., & Gabaldon, A. M. (2008) · Integrative and Comparative Biology · doi:10.1093/icb/icn056 · Cited by 173
Towards Wearable A-Mode Ultrasound Sensing for Real-Time Finger Motion Recognition
Yang, X., Sun, X., Zhou, D., Li, Y., & Liu, H. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2829913 · Cited by 169
A Review of Force Myography Research and Development
Xiao, Z. G., & Menon, C. (2019) · Sensors · doi:10.3390/s19204557 · Cited by 169
Individualization of exosuit assistance based on measured muscle dynamics during versatile walking
Nuckols, R. W., Lee, S., Swaminathan, K., Orzel, D., Howe, R. D., & Walsh, C. J. (2021) · Science Robotics · doi:10.1126/scirobotics.abj1362 · Cited by 162
Self-citationTraining Load and Injury: Causal Pathways and Future Directions
Kalkhoven, J. T., Watsford, M. L., Coutts, A. J., Edwards, W. B., & Impellizzeri, F. M. (2021) · Sports Medicine · doi:10.1007/s40279-020-01413-6 · Cited by 159
Biomechanics of the elbow in sports
Loftice, J., Fleisig, G. S., Zheng, N., & Andrews, J. R. (2004) · Clinics in Sports Medicine · doi:10.1016/j.csm.2004.06.003 · Cited by 138
A Review of Occupational Knee Disorders
Reid, C. R., McCauley-Bell, P., Cummings, N. H., McMullin, D. L., & Durrani, S. K. (2010) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-010-9242-8 · Cited by 132
Electro-mechanical stability of surface EMG sensors
Roy, S. H., Luca, G. D., Cheng, M. S., Johansson, A., Gilmore, L., & Luca, C. J. D. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0168-z · Cited by 127
Dick, T. J. M., Biewener, A. A., & Wakeling, J. M. (2017) · Journal of Experimental Biology · doi:10.1242/jeb.154807 · Cited by 126
Measuring biomechanical loads in team sports – from lab to field
Verheul, J., Nedergaard, N. J., Vanrenterghem, J., & Robinson, M. A. (2020) · Science and Medicine in Football · doi:10.1080/24733938.2019.1709654 · Cited by 124
Structural Determinants of Muscle Gearing During Dynamic Contractions
Eng, C. M., Azizi, E., & Roberts, T. J. (2018) · Integrative and Comparative Biology · doi:10.1093/icb/icy054 · Cited by 102
Nuckols, R. W., Takahashi, K. Z., Farris, D. J., Mizrachi, S., Riemer, R., & Sawicki, G. S. (2020) · PLOS ONE · doi:10.1371/journal.pone.0231996 · Cited by 101
Self-citationThe Multi-Scale, Three-Dimensional Nature of Skeletal Muscle Contraction
Roberts, T. J., Eng, C. M., Sleboda, D. A., Holt, N. C., Brainerd, E. L., Stover, K. K., Marsh, R. L., & Azizi, E. (2019) · Physiology · doi:10.1152/physiol.00023.2019 · Cited by 89
He, J., Luo, H., Jia, J., Yeow, J. T. W., & Jiang, N. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2872593 · Cited by 80
Muscle gearing during isotonic and isokinetic movements in the ankle plantarflexors
Randhawa, A., Jackman, M. E., & Wakeling, J. M. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2448-z · Cited by 80
Dynamic monitoring of forearm muscles using one-dimensional sonomyography system
Guo, J., Zheng, Y.-P., Huang, Q.-H., & Chen, X. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.02.0026 · Cited by 79
Wei, S. X., Zhang, Y., & Liu, H. (2022) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2022.3204343 · Cited by 76
A Proportional Pattern Recognition Control Scheme for Wearable A-mode Ultrasound Sensing
Yang, X., Yan, J., Chen, Z., Ding, H., & Liu, H. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2898614 · Cited by 75
Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies
Ravary‐Plumioën, B., Pourcelot, P., Bortolussi, C., Konieczka, S., & Crevier‐Denoix, N. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.01.008 · Cited by 73
Effects of changing speed on knee and ankle joint load during walking and running
de David, A. C., Carpes, F. P., & Stefanyshyn, D. J. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.946074 · Cited by 72
Assessment of muscle activity using electrical stimulation and mechanomyography: a systematic review
Uwamahoro, R., Sundaraj, K., & Subramaniam, I. D. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00840-w · Cited by 66
Towards Soft Wearable Strain Sensors for Muscle Activity Monitoring
Alvarez, J. T., Gerez, L. F., Araromi, O. A., Hunter, J. G., Choe, D. K., Payne, C. J., Wood, R. J., & Walsh, C. J. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3196501 · Cited by 64
Self-citationChen, X., Zheng, Y., Guo, J.-Y., Zhu, Z., Chan, S. C., & Zhang, Z. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2227-2 · Cited by 62
Wakeling, J. M., Febrer-Nafría, M., & Groote, F. D. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111657 · Cited by 62
Soft Sensing Shirt for Shoulder Kinematics Estimation
Jin, Y., Glover, C., Cho, H., Araromi, O. A., Graule, M. A., Li, N., Wood, R. J., & Walsh, C. J. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9196586 · Cited by 61
Self-citationSegmenting Mechanomyography Measures of Muscle Activity Phases Using Inertial Data
Woodward, R. B., Stokes, M. J., Shefelbine, S. J., & Vaidyanathan, R. (2019) · Scientific Reports · doi:10.1038/s41598-019-41860-4 · Cited by 60
Rupp, S., Hopf, T., Hess, T., Seil, R., & Kohn, D. (1999) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/ar.1999.v15.0150171 · Cited by 57
Modulation of Achilles tendon force with load carriage and exosuit assistance
Schmitz, D. G., Nuckols, R. W., Lee, S., Akbaş, T., Swaminathan, K., Walsh, C. J., & Thelen, D. G. (2022) · Science Robotics · doi:10.1126/scirobotics.abq1514 · Cited by 51
Self-citationCzaplicki, A., Jarocka, M., & Walawski, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0144283 · Cited by 50
Bretschneider, S. F., Los, F. S., Eygendaal, D. E., Kuijer, P., & van der Molen, H. F. (2021) · American Journal of Industrial Medicine · doi:10.1002/ajim.23303 · Cited by 48
A Gesture Recognition Strategy Based on A-Mode Ultrasound for Identifying Known and Unknown Gestures
Guo, L., Lu, Z., Yao, L., & Cai, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3167696 · Cited by 46
Lute, A. C., & Luce, C. H. (2017) · Water Resources Research · doi:10.1002/2017wr020752 · Cited by 41
Bio-signal based elbow angle and torque simultaneous prediction during isokinetic contraction
Zhou, Y., Liu, J., Zeng, J., Li, K., & Liu, H. (2019) · Science China Technological Sciences · doi:10.1007/s11431-018-9354-5 · Cited by 30
Sartori, M., & Sawicki, G. S. (2021) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/abe3e0 · Cited by 29
Qing, Z., Lu, Z., Zhoujie, L., Cai, Y., Cai, S., Baizheng, H., & Yao, L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3196926 · Cited by 27
Muscle deformation correlates with output force during isometric contraction
Hallock, L. A., Velu, A., Schwartz, A., & Bajcsy, R. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224391 · Cited by 18
Mendez, J., Murray, R. C., Gabert, L., Fey, N. P., Liu, H., & Lenzi, T. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3248647 · Cited by 16
Brausch, L., Hewener, H., & Lukowicz, P. (2022) · Sensors · doi:10.3390/s22072789 · Cited by 15
Murray, R. C., Mendez, J., Gabert, L., Fey, N. P., Liu, H., & Lenzi, T. (2022) · Sensors · doi:10.3390/s22239350 · Cited by 13
Surface‐Level Muscle Deformation as a Correlate for Joint Torque
Alvarez, J. T., de Marcillac, A., Jin, Y., Gerez, L. F., Araromi, O. A., & Walsh, C. J. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400444 · Cited by 12
Self-citationOtsuka, S., Shan, X., Kurumisawa, K., Omura, S., Yamagishi, T., Naito, M., & Kawakami, Y. (2021) · Journal of Anatomy · doi:10.1111/joa.13505 · Cited by 9
Jin, Y., Zhou, Y. M., McCann, C. M., Proietti, T., Rycroft, C. H., & Walsh, C. J. (2022) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob52689.2022.9925393 · Cited by 9
Self-citationA preliminary study on the relationship between grip force and muscle thickness
Yang, X., Li, Y., Fang, Y., & Liu, H. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008306 · Cited by 8
Duplex Ultrasonic Muscle Activity Sensor
Tsutsui, Y., Tanaka, T., Kaneko, S., & Feng, M. Q. (2006) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2005.1597698 · Cited by 7
Age-Related Reliability of B-Mode Analysis for Tailored Exosuit Assistance
Gionfrida, L., Nuckols, R. W., Walsh, C. J., & Howe, R. D. (2023) · Sensors · doi:10.3390/s23031670 · Cited by 6
Self-citationBaltzopoulos, V. (2007) · Routledge eBooks · doi:10.4324/9780203935750-11 · Cited by 4
Research works printed but not linked: 2
- Zernicke R Whiting W Mechanisms of musculoskeletal injury Biomech. Sport. Perform. Enhancement Inj. Prev. 2000 507 522
- Muscolino, J. E. The Muscular System Manual: The Skeletal Muscles of the Human Body (Elsevier Health Sciences).
Cited by
Emerging Wearable Acoustic Sensing Technologies
Liu, T., Mao, Y., Dou, H., Zhang, W., Yang, J., Wu, P., Li, D., & Mu, X. (2025) · Advanced Science · doi:10.1002/advs.202408653 · Cited by 93
Guo, X., Zhang, Z., Ren, Z., Li, D., Xu, C., Wang, L., Liu, W., Zhuge, Y., Zhou, G., & Lee, C. (2025) · Advanced Materials · doi:10.1002/adma.202510417 · Cited by 74
Unperceivable Designs of Wearable Electronics
Liu, Y., de Mulatier, S., & Matsuhisa, N. (2025) · Advanced Materials · doi:10.1002/adma.202502727 · Cited by 64
Alternative Micro/Nanofabrication Approaches for Wearable Electronics
Zhang, J., & Wang, M. (2026) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00801 · Cited by 56
AI-Enabled Piezoelectric Wearable for Joint Torque Monitoring
Chang, J., Li, J., Ye, J., Zhang, B., Chen, J., Xia, Y., Lei, J., Carlson, T., Loureiro, R. C. V., Korsunsky, A. M., et al. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01753-w · Cited by 47
Metadata
- Authors
- Jin, Y., Alvarez, J. T., Suitor, E. L., Swaminathan, K., Chin, A., Civici, U. S., Nuckols, R. W., Howe, R. D., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- University of Massachusetts Lowell (US)
- Corresponding author
- Walsh, Conor J.
- ORCID
- Venue
- Nature Communications
- Published
- 2024-07-09
- Volume
- 15
- Issue
- 1
- Pages
- 5756-5756
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC11233567
- OpenAlex
- W4400445480
- Cited by
- 58
- References
- 71
- Citations by year
- 2026: 25 · 2025: 28 · 2024: 5
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Department of Health & Human Services | National Institutes of Health (R21AR076686)
- Harvard University | Harvard School of Engineering and Applied Sciences
- National Science Foundation (DGE2140743)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- joint torque estimation, wearable ultrasound, A-mode ultrasound, elbow torque, knee joint torque, isokinetic contraction, weightlifting, cycling, locomotion, musculoskeletal load, injury prevention, rehabilitation
- MeSH terms
- Wearable Electronic Devices, Adult, Biomechanical Phenomena, Elbow Joint, Female, Humans, Joints, Knee Joint, Male, Movement, Muscle Contraction, Ultrasonography, Muscle, Skeletal, Torque, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.