The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fast-forming hydrogel with ultralow polymeric content as an artificial vitreous body
Open accessAbstract
Degradation-induced swelling in implanted hydrogels can cause severe adverse reactions in surrounding tissues. Here, we report a new class of hydrogel with extremely low swelling pressure, and demonstrate its use as an artificial vitreous body. The hydrogel has ultralow polymer content (4.0 g l−1), low cytotoxicity, and forms in situ in 10 minutes via the crosslinking of clusters of highly branched polymers of tetra-armed poly(ethylene glycol) prepolymers. After injection and gelation in the eyes of rabbits, the hydrogel functioned as an artificial vitreous body for over a year without adverse effects, and proved effective for the treatment of retinal detachment. The properties of the hydrogel make it a promising candidate as an infill biomaterial for a range of biomedical applications. A hydrogel made of crosslinked clusters of highly branched polymers that has ultralow swelling pressure and that forms in 10 minutes despite its low polymer content functions as an artificial vitreous body for over one year without inducing adverse effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sakai, T., Matsunaga, T., Yamamoto, Y., Ito, C., Yoshida, R., Suzuki, S., Sasaki, N., Shibayama, M., & Chung, U.-I. (2008) · Macromolecules · doi:10.1021/ma800476x · Cited by 1,274
Self-citation“Nonswellable” Hydrogel Without Mechanical Hysteresis
Kamata, H., Akagi, Y., Kayasuga-Kariya, Y., Chung, U.-I., & Sakai, T. (2014) · Science · doi:10.1126/science.1247811 · Cited by 669
Self-citation
Cited by
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Tailoring the Swelling‐Shrinkable Behavior of Hydrogels for Biomedical Applications
Feng, W., & Wang, Z. (2023) · Advanced Science · doi:10.1002/advs.202303326 · Cited by 548
Methods To Assess Shear-Thinning Hydrogels for Application As Injectable Biomaterials
Chen, M. H., Wang, L. L., Chung, J. J., Kim, Y.-H., Atluri, P., & Burdick, J. A. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00734 · Cited by 504
Gao, Y., Peng, K., & Mitragotri, S. (2021) · Advanced Materials · doi:10.1002/adma.202006362 · Cited by 295
Metadata
- Authors
- Hayashi, K., Okamoto, F., Hoshi, S., Katashima, T., Zujur, D. C., Li, X., Shibayama, M., Gilbert, E. P., Chung, U.-I., Ohba, S., Oshika, T., & Sakai, T.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-03-09
- Volume
- 1
- Issue
- 3
- Pages
- 0044
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2592964248
- Cited by
- 214
- References
- 2
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast-forming hydrogel with ultralow polymeric content as an artificial vitreous body. https://app.cochat.ai/papers/10.1038/s41551-017-0044
- The paper
- Hayashi, K., Okamoto, F., Hoshi, S., Katashima, T., Zujur, D. C., Li, X., Shibayama, M., Gilbert, E. P., Chung, U.-I., Ohba, S., Oshika, T., & Sakai, T. (2017). Fast-forming hydrogel with ultralow polymeric content as an artificial vitreous body. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-017-0044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.