Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 262

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Microscopy with ultraviolet surface excitation for rapid slide-free histology

Open access
Fereidouni, Farzad, Harmany, Zachary T., Tian, Miao, Todd, Austin, Kintner, John A., McPherson, John D., Borowsky, Alexander D., Bishop, John, Lechpammer, Mirna, Demos, Stavros G., Levenson, Richard · 2017 · Nature Biomedical Engineering

Abstract

Histological examination of tissues is central to the diagnosis and management of neoplasms and many other diseases and is a foundational technique for preclinical and basic research. However, commonly used bright-field microscopy requires prior preparation of micrometre-thick tissue sections mounted on glass slides—a process that can require hours or days, contributes to cost and delays access to critical information. Here, we introduce a simple, non-destructive slide-free technique that, within minutes, provides high-resolution diagnostic histological images resembling those obtained from conventional haematoxylin and eosin histology. The approach, which we named microscopy with ultraviolet surface excitation (MUSE), can also generate shape and colour-contrast information. MUSE relies on ~280 nm ultraviolet light to restrict the excitation of conventional fluorescent stains to tissue surfaces and it has no significant effects on downstream molecular assays (including fluorescence in situ hybridization and RNA sequencing). MUSE promises to improve the speed and efficiency of patient care in both state-of-the-art and low-resource settings and to provide opportunities for rapid histology in research. A slide-free, inexpensive and non-destructive microscopy technique rapidly provides high-resolution histology images that resemble those obtained from conventional haematoxylin-and-eosin-stained specimens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-017-0165-y

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 262

Metadata

Authors
Fereidouni, F., Harmany, Z. T., Tian, M., Todd, A., Kintner, J. A., McPherson, J. D., Borowsky, A. D., Bishop, J., Lechpammer, M., Demos, S. G., & Levenson, R.
Venue
Nature Biomedical Engineering
Published
2017-12-04
Volume
1
Issue
12
Pages
957-966
ISSN
2157-846X (ISSN-L)
OpenAlex
W2771842941
Cited by
262
References
23
FWCI
11.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microscopy with ultraviolet surface excitation for rapid slide-free histology. https://app.cochat.ai/papers/10.1038/s41551-017-0165-y
The paper
Fereidouni, F., Harmany, Z. T., Tian, M., Todd, A., Kintner, J. A., McPherson, J. D., Borowsky, A. D., Bishop, J., Lechpammer, M., Demos, S. G., & Levenson, R. (2017). Microscopy with ultraviolet surface excitation for rapid slide-free histology. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-017-0165-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.