Pre-symptomatic detection of COVID-19 from smartwatch data
Open accessPublished version of a preprint
The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Consumer wearable devices that continuously measure vital signs have been used to monitor the onset of infectious disease. Here, we show that data from consumer smartwatches can be used for the pre-symptomatic detection of coronavirus disease 2019 (COVID-19). We analysed physiological and activity data from 32 individuals infected with COVID-19, identified from a cohort of nearly 5,300 participants, and found that 26 of them (81%) had alterations in their heart rate, number of daily steps or time asleep. Of the 25 cases of COVID-19 with detected physiological alterations for which we had symptom information, 22 were detected before (or at) symptom onset, with four cases detected at least nine days earlier. Using retrospective smartwatch data, we show that 63% of the COVID-19 cases could have been detected before symptom onset in real time via a two-tiered warning system based on the occurrence of extreme elevations in resting heart rate relative to the individual baseline. Our findings suggest that activity tracking and health monitoring via consumer wearable devices may be used for the large-scale, real-time detection of respiratory infections, often pre-symptomatically. Analysis of physiological and activity data from consumer smartwatches enables real-time detection, often before symptom onset, of COVID-19, as well as other respiratory illnesses and stress inducers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Wearable biochemical and biophysical sensors have been used to detect and manage diseases1,12–15 and for wellness applications16–18.”
From End-to-end design of wearable sensors (2022) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249
Wickham, H. (2016) · Use R! · doi:10.1007/978-3-319-24277-4 · Cited by 33,115
ggplot2: Elegant Graphics for Data Analysis
Wickham, H. (2009) · doi:10.1007/978-0-387-98141-3 · Cited by 14,447
Lauer, S. A., Grantz, K. H., Bi, Q., Jones, F. K., Zheng, Q., Meredith, H. R., Azman, A. S., Reich, N. G., & Lessler, J. (2020) · Annals of Internal Medicine · doi:10.7326/m20-0504 · Cited by 5,970
Temporal dynamics in viral shedding and transmissibility of COVID-19
He, X., Lau, E. H. Y., Wu, P., Deng, X., Wang, J., Hao, X., Lau, Y. C., Wong, J. Y., Guan, Y., Tan, X., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0869-5 · Cited by 4,247
A Fast Algorithm for the Minimum Covariance Determinant Estimator
Rousseeuw, P. J., & Driessen, K. V. (1999) · Technometrics · doi:10.1080/00401706.1999.10485670 · Cited by 2,708
Prevalence of Asymptomatic SARS-CoV-2 Infection: A Narrative Review
Oran, D. P., & Topol, E. J. (2020) · Annals of Internal Medicine · doi:10.7326/m20-3012 · Cited by 2,279
Presymptomatic SARS-CoV-2 Infections and Transmission in a Skilled Nursing Facility
Arons, M. M., Hatfield, K. M., Reddy, S. C., Kimball, A., James, A., Jacobs, J. R., Taylor, J., Spicer, K., Bardossy, A. C., Oakley, L. P., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2008457 · Cited by 2,052
Bi, Q., Wu, Y., Mei, S., Ye, C., Zou, X., Zhang, Z., Liu, X., Wei, L., Truelove, S. A., Zhang, T., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30287-5 · Cited by 1,958
Cited by
Items 501–545 of 545
Proactive and Reactive Auto-scaling Techniques for Edge Computing
Gupta, S., Islam, M. T., & Buyya, R. (2026) · Springer handbooks · doi:10.1007/978-3-031-92372-2_32
AI and Machine Learning in Pandemic Surveillance: Ethics and Security Implications
Olorunlana, T. J. (2024) · International Journal of Science Architecture Technology and Environment · doi:10.63680/ijsate052454.09
Wahidah, W., Sari, N., & Ayumi, K. F. (2026) · PREPOTIF Jurnal Kesehatan Masyarakat · doi:10.31004/prepotif.v10i1.55176
Heath, R. A. (2022) · medRxiv · doi:10.1101/2022.10.27.22281632
Mayer, C. (2023) · Deep Blue (University of Michigan) · doi:10.7302/8272
Karthik Subramanian, E. N., Nagapriyanka, E., Majeti, V. P. K., Bhavani, C. G., Swetha, A. L., & Dhayanithi, N. B. (2025) · International Journal of Environmental Sciences · doi:10.64252/05adh787
A Multi-Model Machine Learning Approach for Predictive Analytics and Intelligent Decision Making
Manivannan, K. (2026) · Journal of Intelligent Decision Making and Information Science · doi:10.59543/jidmis.v3.1783
Cleary, J. L., Fang, Y., Sen, S., & Wu, Z. (2022) · doi:10.1371/journal.pone.0277350.r004
Efficiently classifying shocks in complex systems requires dormant reportersPreprint
Brewster, D. A., & Cluzel, P. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2609.00725
Dhanasekar, J., Lathamani, L., Selvakumar, M., Sudhamani, T., Nandhakumaran, S., & Tamizharasi, S. (2025) · Biomedicine · doi:10.51248/v46i1.187
Decentralized Epidemic Tracking using Federated Learning and Edge AI on Consumer Wearables
Hariharan., N., Abikayil Aarthi., S., Ajav., V., Gurudev., N., Deerga Tharsan, A., V, Mukilan., C., V, & Aravinth., R. (2026) · INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT · doi:10.55041/ijsrem67933
Gomes, B., de Lima, M. S. G., MEDEIROS, R. D. L., Ferreira, A. C. D. A., NASCIMENTO, A. K. G. D., de Souza, R. J. P., Fittipaldi, E. O. D. S., & Fernandes, J. (2026) · Conexão Ciência (Online) · doi:10.24862/cco.v21i1.2224
Wearable Biosensors and Remote Patient Monitoring
Raza, S. N., Akhtar, M. R., & Khan, I. (2026) · doi:10.70593/978-81-6632-168-9
Wiebe, M., Mackay, M., Krishnan, R., Tian, J., Larsson, J., Modanloo, S., McIntosh, C. J., Sztym, M., Elton-Smith, G., Rose, A., et al. (2024) · doi:10.1371/journal.pdig.0000571.r002
To, S. M. (2020) · Research Repository (Delft University of Technology)
Personalized Baselines in Vital Signs: Insights from Wearable-Derived Sleep Data in Healthy Adults
Sarani, N., Che, R., Jackson, B. S., Hanson, C., Selby, S., Ronvelia, D., Wilson, M., Gude, K. P., & Fernandes, R. L. (2025) · Journal of Biotechnology and Biomedicine · doi:10.26502/jbb.2642-91280197
De waardegedreven acceptatie van smartwatches
Bonneux, S. (2023) · Document Server@UHasselt (UHasselt)
Hierarchical heated markov modeling for synthesizing activity data from wearable devices
Fang, D., & Ruan, D. (2026) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2025.11.053
Nocturnal cough as a syndromic surveillance signal for respiratory illness in EnglandPreprint
Irons, T., Carlsson, E., Tang, M. L., Mellor, J., Rubin, C., Allen, A., Elliot, A. J., Kågebäck, M., & Packham, J. (2026) · medRxiv · doi:10.64898/2026.07.20.26357937
Umate, O. A., Salunkhe, S. P., Tripathi, S., Potghan, P. P., Nair, R., & Dhotre, P. S. (2026) · International Journal of Science and Research Archive · doi:10.30574/ijsra.2026.21.2.2029
Wearable and BAN Sensors for Physical Rehabilitation and eHealth Architectures
Domingues, M. F., Sciarrone, A., & Radwan, A. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-2813-7
Grossmann, K., Risch, M., Markovic, A., Aeschbacher, S., Weideli, O. C., Velez, L., Kovac, M., Pereira, F., Wohlwend, N., Risch, C., et al. (2024) · doi:10.1371/journal.pone.0292203.r003
Wearable Technologies for Vaccines and Therapeutics in Infectious Diseases: A Scoping ReviewPreprint
Shahmoon, E., Nemet, D., & Yamin, D. (2026) · Research Square · doi:10.21203/rs.3.rs-10445370/v1
Silvestre, T. R., Santos, E. M. D., Pinto, R. A., & Evangelista, L. G. C. (2022) · doi:10.5753/sbcas.2022.222546
Artificial Intelligence in Biosensing and Wearable Health Monitoring
Gao, J. (2026) · Theoretical and Natural Science · doi:10.54254/2753-8818/2027.mb39152
Physiological Behavior of COVID-19 Patients Using Wearable System and Markov Chains
Viera, E., Héctor Kaschel, C., & Valencia, C. (2021) · IEEE CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON) · doi:10.1109/chilecon54041.2021.9702977
Canali, S. (2021) · InTrasformazione: rivista di storia delle idee · doi:10.4474/dps/10/01/dss504/09
A Recent Review on Machine Learning Applications and Deep Learning Techniques for Handling Pandemics
Zayoud, M., Oueida, S., & Al-Hajj, R. (2023) · Lecture notes in networks and systems · doi:10.1007/978-981-99-3236-8_89
Valadão, C., Silva, L., Lampier, L., Coelho, Y., Delisle-Rodríguez, D., Caldeira, E. M. D. O., & Bastos-Filho, T. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49407-9_42
Polido, S., Napoli, O. O., Breternitz, M., & de Almeida, A. (2024) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon56669.2024.10608642
Manyuha, I. M., & Lubinga, E. (2025) · The Thinker · doi:10.36615/rssqac09
白, 春., 蒋, 维., & 王, 洵. (2025) · 元宇宙医学. · doi:10.61189/977285vvilzw
Suporte wearable para Mobile Documents (mDoc) ISO/IEC 18013-5
Matias, H. F. (2023) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Big Tech und die Pandemie – Smarte Retter in der Not?
Nosthoff, A.-V., & Maschewski, F. (2021) · PhilPapers (PhilPapers Foundation)
Monitoramento da Saúde Vocal empregando Sensor Piezoelétrico e IoT
Mendes, L., Silva, I. F., Lima, T., & Correia, S. (2025) · Anais de XXXV Simpósio Brasileiro de Telecomunicações e Processamento de Sinais · doi:10.14209/sbrt.2025.1571156740
von Preyss-Friedman, S. M., Emmet, L., Deckert, D., David, D. A. B., Baudino, J.-L., Strachan, I., Didcote, S., Räisänen, H., Longoria, K., Gielen, W., et al. (2026) · doi:10.36227/techrxiv.177078582.23173356/v1
IoT pulse oximetry model for early detection of COVID-19
Bonyo, L. (2021) · SU+ Digital Repository (Strathmore University)
Alafeef, M. (2023) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Xiong, Y., Zheng, Z., Tang, Y., Liao, Y., Cheng, G., Wang, T., Wang, Y., Fu, Z., Wang, Y., Fang, P., et al. (2026) · Advanced Materials · doi:10.1002/adma.75265
Self-citationOnline Imputation Analysis for Anomaly Heart Rate Detection in Wearable Data Streams
Lima, A. M. S., Uchida, M. A. S., Traina, A. J. M., & Sousa, E. P. M. (2026) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms69103.2026.00166
Impacto de Mecanismos de Ausência de Dados na Performance de um Sistema de Monitoramento de COVID-19
Cardoso, L. S., Lima, A. M. S., Traina, A. J. M., & Sousa, E. P. M. (2026) · Simpósio Brasileiro de Bancos de Dados (SBBD) · doi:10.5753/sbbd_estendido.2026.249613
Metadata
- Authors
- Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., Celli, A., Higgs, E., Dagan-Rosenfeld, O., Fay, B., Kirkpatrick, S., Kellogg, R., Gibson, M., Wang, T., Hunting, E. M., Mamic, P., Ganz, A. B., Rolnik, B., Li, X., & Snyder, M. P.
- Venue
- Nature Biomedical Engineering
- Published
- 2020-11-18
- Volume
- 4
- Issue
- 12
- Pages
- 1208-1220
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3104096625
- Cited by
- 463
- References
- 37
- FWCI
- 23.59
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.