CoChat

Pre-symptomatic detection of COVID-19 from smartwatch data

Open access
Mishra, Tejaswini, Wang, Meng, Metwally, Ahmed A., Bogu, Gireesh K., Brooks, Andrew W., Bahmani, Amir, Alavi, Arash, Celli, Alessandra, Higgs, Emily, Dagan-Rosenfeld, Orit, Fay, Bethany, Kirkpatrick, Susan, Kellogg, Ryan, Gibson, Michelle, Wang, Tao, Hunting, Erika M., Mamic, Petra, Ganz, Ariel B., Rolnik, Benjamin, Li, Xiao, Snyder, Michael P. · 2020 · Nature Biomedical Engineering

Published version of a preprint

Cited by 545

The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

Consumer wearable devices that continuously measure vital signs have been used to monitor the onset of infectious disease. Here, we show that data from consumer smartwatches can be used for the pre-symptomatic detection of coronavirus disease 2019 (COVID-19). We analysed physiological and activity data from 32 individuals infected with COVID-19, identified from a cohort of nearly 5,300 participants, and found that 26 of them (81%) had alterations in their heart rate, number of daily steps or time asleep. Of the 25 cases of COVID-19 with detected physiological alterations for which we had symptom information, 22 were detected before (or at) symptom onset, with four cases detected at least nine days earlier. Using retrospective smartwatch data, we show that 63% of the COVID-19 cases could have been detected before symptom onset in real time via a two-tiered warning system based on the occurrence of extreme elevations in resting heart rate relative to the individual baseline. Our findings suggest that activity tracking and health monitoring via consumer wearable devices may be used for the large-scale, real-time detection of respiratory infections, often pre-symptomatically. Analysis of physiological and activity data from consumer smartwatches enables real-time detection, often before symptom onset, of COVID-19, as well as other respiratory illnesses and stress inducers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-020-00640-6

Cites

37 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 545

Metadata

Authors
Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., Celli, A., Higgs, E., Dagan-Rosenfeld, O., Fay, B., Kirkpatrick, S., Kellogg, R., Gibson, M., Wang, T., Hunting, E. M., Mamic, P., Ganz, A. B., Rolnik, B., Li, X., & Snyder, M. P.
Venue
Nature Biomedical Engineering
Published
2020-11-18
Volume
4
Issue
12
Pages
1208-1220
ISSN
2157-846X (ISSN-L)
OpenAlex
W3104096625
Cited by
463
References
37
FWCI
23.59
Type
journal article
Language
en
Open access
bronze
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.