A portable scanner for magnetic resonance imaging of the brain
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Access to scanners for magnetic resonance imaging (MRI) is typically limited by cost and by infrastructure requirements. Here, we report the design and testing of a portable prototype scanner for brain MRI that uses a compact and lightweight permanent rare-earth magnet with a built-in readout field gradient. The 122-kg low-field (80 mT) magnet has a Halbach cylinder design that results in a minimal stray field and requires neither cryogenics nor external power. The built-in magnetic field gradient reduces the reliance on high-power gradient drivers, lowering the overall requirements for power and cooling, and reducing acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique that leverages previous characterization of the field patterns. In healthy adult volunteers, the scanner can generate T1-weighted, T2-weighted and proton density-weighted brain images with a spatial resolution of 2.2 × 1.3 × 6.8 mm3. Future versions of the scanner could improve the accessibility of brain MRI at the point of care, particularly for critically ill patients. A portable prototype scanner for brain MRI that uses a compact and lightweight permanent rare-earth magnet with a built-in readout field gradient generates clinically relevant images of the brain, as shown in adult volunteers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Feigin, V. L., Nichols, E., Alam, T., Bannick, M. S., Beghi, E., Blake, N., Culpepper, W. J., Dorsey, E. R., Elbaz, A., Ellenbogen, R. G., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30499-x · Cited by 5,644
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Design of permanent multipole magnets with oriented rare earth cobalt material
Halbach, K. (1980) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(80)90094-4 · Cited by 1,532
Moore, G. E. (2006) · IEEE Solid-State Circuits Society Newsletter · doi:10.1109/n-ssc.2006.4785860 · Cited by 854
Beckmann, U., Gillies, D. M., Berenholtz, S. M., Wu, A. W., & Pronovost, P. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2177-9 · Cited by 620
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Sarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Self-citationThe Energy Consumption of Radiology: Energy- and Cost-saving Opportunities for CT and MRI Operation
Heye, T. J., Knoerl, R., Wehrle, T., Mangold, D., Cerminara, A., Loser, M., Plumeyer, M., Degen, M., Lüthy, R., Brodbeck, D., et al. (2020) · Radiology · doi:10.1148/radiol.2020192084 · Cited by 290
Wald, L. L., McDaniel, P. C., Witzel, T., Stockmann, J. P., & Cooley, C. Z. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26942 · Cited by 272
Self-citationAccessible magnetic resonance imaging: A review
Geethanath, S., & Vaughan, J. T. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26638 · Cited by 244
Transport, monitoring, and successful brain MR imaging in unsedated neonates
Mathur, A. M., Neil, J. J., McKinstry, R. C., & Inder, T. E. (2008) · Pediatric Radiology · doi:10.1007/s00247-007-0705-9 · Cited by 208
Two‐dimensional imaging in a lightweight portable MRI scanner without gradient coils
Cooley, C. Z., Stockmann, J., Armstrong, B. D., Sarracanie, M., Lev, M. H., Rosen, M. S., & Wald, L. L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25147 · Cited by 175
Self-citationParallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study
Hennig, J., Welz, A. M., Schultz, G., Korvink, J. G., Liu, Z., Speck, O., & Zaitsev, M. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0105-7 · Cited by 163
Design of Sparse Halbach Magnet Arrays for Portable MRI Using a Genetic Algorithm
Cooley, C. Z., Haskell, M. W., Cauley, S., Sappo, C. R., LaPierre, C., Ha, C. G., Stockmann, J., & Wald, L. L. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2751001 · Cited by 138
Self-citationWarf, B. C. (2010) · World Neurosurgery · doi:10.1016/j.wneu.2010.02.009 · Cited by 128 · cited 1×
“Finally, accessible, low-cost MRI could benefit remote low and middle income regions both in the US and abroad, for example to monitor treatment of pediatric hydrocephalus in Sub-Sahara Africa 5 .”
Stockmann, J., Ciris, P. A., Galiana, G., Tam, L., & Constable, R. T. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22425 · Cited by 107
Self-citationLightweight, compact, and high‐performance 3 T MR system for imaging the brain and extremities
Foo, T., Laskaris, E. T., Vermilyea, M. E., Xu, M., Thompson, P., Conte, G., Epps, C. V., Immer, C., Lee, S., Tan, E. T., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27175 · Cited by 100
McDaniel, P. C., Cooley, C. Z., Stockmann, J., & Wald, L. L. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27861 · Cited by 93
Self-citationRen, Z. H., Mu, W. C., & Huang, S. Y. (2018) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2018.2876679 · Cited by 71
Schultz, G., Ullmann, P., Lehr, H., Welz, A. M., Hennig, J., & Zaitsev, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22393 · Cited by 70
Reconstruction of MRI data encoded by multiple nonbijective curvilinear magnetic fields
Lin, F., Witzel, T., Schultz, G., Gallichan, D., Kuo, W., Wang, F., Hennig, J., Zaitsev, M., & Belliveau, J. W. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24115 · Cited by 34
Matter, N. I., Scott, G., Venook, R. D., Ungersma, S. E., Grafendorfer, T., Macovski, A., & Conolly, S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21065 · Cited by 25
Performance of Shielded Electromagnet-Evaluation Under Low-Frequency Excitation
Bringout, G., Gräfe, K., & Buzug, T. M. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2329396 · Cited by 9
Cited by
Low‐field MRI: Clinical promise and challenges
Arnold, T. C., Freeman, C. W., Litt, B., & Stein, J. M. (2023) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28408 · Cited by 374
A low-cost and shielding-free ultra-low-field brain MRI scanner
Liu, Y., Leong, A. T. L., Zhao, Y., Xiao, L., Mak, H. K. F., Tsang, A. C. O., Lau, G. K. K., Leung, G. K. K., & Wu, E. X. (2021) · Nature Communications · doi:10.1038/s41467-021-27317-1 · Cited by 261
Top-Level Design and Simulated Performance of the First Portable CT-MR Scanner
Peng, Y., Li, M., Grandinetti, J., Wang, G., & Jia, X. (2022) · IEEE Access · doi:10.1109/access.2022.3208278 · Cited by 4
Metadata
- Authors
- Cooley, C. Z., McDaniel, P. C., Stockmann, J. P., Srinivas, S. A., Cauley, S. F., Śliwiak, M., Sappo, C. R., Vaughn, C. F., Guerin, B., Rosen, M. S., Lev, M. H., & Wald, L. L.
- Venue
- Nature Biomedical Engineering
- Published
- 2020-11-23
- Volume
- 5
- Issue
- 3
- Pages
- 229-239
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3110229364
- Cited by
- 251
- References
- 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.