Abstract

Multi-modality imaging hardware can be integrated in a single gantry to collect diverse datasets for complementary information and spatiotemporal correlation, with excellent examples including PET-CT and PET-MRI. However, there is no CT-MRI prototype up to today due to technical challenges and associated cost-benefit considerations. Thanks to the rapid development of medical imaging, it becomes feasible now to integrate cost-effective CT and MRI imagers together for portability, popularity, and point of care. In this paper, we present the top-level design of the first portable CT-MRI system and evaluate its imaging performance via realistic numerical simulations. In this CT-MRI system, the magnet made of two neodymium (NdFeB) rings of about 40.0 cm radius forms a magnetic field of about 57 mT at the isocenter and has a gap of 11.3 cm to accommodate the rotating CT gantry. The targeted MR imaging field of view (FOV) is a sphere of ~15 cm in diameter and that of CT is approximately 20 cm diameter in axial direction and 5 cm in longitudinal direction. Our results show a great potential of such a hybrid system. The proposed CT-MRI system will be valuable in applications such as imaging in underdeveloped countries, disaster scenes and battle fields.

Overview

Integrity signals

Registry

Crossref · 10.1109/access.2022.3208278

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 29 references

Cited by

See all 4

Metadata

Authors
Peng, Y., Li, M., Grandinetti, J., Wang, G., & Jia, X.
Affiliations
  • The University of Texas Southwestern Medical Center (US)
  • Rensselaer Polytechnic Institute (US)
  • Johns Hopkins University (US)
Venue
IEEE Access
Published
2022
Volume
10
Pages
102325-102333
ISSN
2169-3536 (ISSN-L)
OpenAlex
W4296558728
Cited by
4
References
29
Citations by year
2026: 1 · 2025: 2 · 2022: 1
FWCI
0.43
Type
journal article
Language
en
Open access
Locations
  • IEEE Access (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University) (cc-by)
Funders
  • National Science Foundation (1636933, 1920920)
  • Cancer Prevention and Research Institute of Texas (RP200573)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
Keywords
portable medical imaging, multi-modality imaging, Nd-Fe-B permanent magnets, point-of-care imaging, field of view

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Top-Level Design and Simulated Performance of the First Portable CT-MR Scanner. https://app.cochat.ai/papers/10.1109/access.2022.3208278
The paper
Peng, Y., Li, M., Grandinetti, J., Wang, G., & Jia, X. (2022). Top-Level Design and Simulated Performance of the First Portable CT-MR Scanner. IEEE Access. https://doi.org/10.1109/access.2022.3208278

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.