The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Single-fluorophore biosensors for sensitive and multiplexed detection of signalling activities
Open accessAbstract
Unravelling the dynamic molecular interplay behind complex physiological processes such as neuronal plasticity requires the ability to both detect minute changes in biochemical states in response to physiological signals and track multiple signalling activities simultaneously. Fluorescent protein-based biosensors have enabled the real-time monitoring of dynamic signalling processes within the native context of living cells, yet most commonly used biosensors exhibit poor sensitivity (for example, due to low dynamic range) and are limited to imaging signalling activities in isolation. Here, we address this challenge by developing a suite of excitation ratiometric kinase activity biosensors that offer the highest reported dynamic range and enable the detection of subtle changes in signalling activity that could not be reliably detected previously, as well as a suite of single-fluorophore biosensors that enable the simultaneous tracking of as many as six distinct signalling activities in single living cells. Mehta et al. create single-fluorophore kinase activity sensors for PKA, PKC and ERK in different colours, and demonstrate that they enable multiplex imaging of a combination of signalling activities in cell lines and primary rat neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging cytosolic NADH-NAD(+) redox state with a genetically encoded fluorescent biosensor
Hung, Y. P., Albeck, J. G., Tantama, M., & Yellen, G. (2011) · Cell Metabolism · doi:10.1016/j.cmet.2011.08.012 · Cited by 509
Sanderson, J. L., Gorski, J. A., & Dell’Acqua, M. L. (2016) · Neuron · doi:10.1016/j.neuron.2016.01.043 · Cited by 210
Diering, G. H., Gustina, A. S., & Huganir, R. L. (2014) · Neuron · doi:10.1016/j.neuron.2014.09.024 · Cited by 153
Self-citation
Cited by
Advancing Biosensors with Machine Learning
Cui, F., Yue, Y., Zhang, Y., Zhang, Z., & Zhou, H. S. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01424 · Cited by 768
Self-citationGreenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
Self-citationOpportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19
Bhalla, N., Pan, Y., Yang, Z., & Payam, A. F. (2020) · ACS Nano · doi:10.1021/acsnano.0c04421 · Cited by 385
Zhang, J. Z., Nguyen, W. H., Greenwood, N., Rose, J. C., Ong, S.-E., Maly, D. J., & Baker, D. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-02107-w · Cited by 37
Self-citationA Genetically Encoded Fluorescent Biosensor for Intracellular Measurement of Malonyl-CoA
Ranzau, B. L., Robinson, T. D., Scully, J. M., Kapelczak, E. D., Dean, T. S., TeSlaa, T., & Schmitt, D. L. (2025) · ACS Bio & Med Chem Au · doi:10.1021/acsbiomedchemau.4c00103 · Cited by 8
Metadata
- Authors
- Mehta, S., Zhang, Y., Roth, R. H., Zhang, J.-F., Mo, A., Tenner, B., Huganir, R. L., & Zhang, J.
- Venue
- Nature Cell Biology
- Published
- 2018-09-24
- Volume
- 20
- Issue
- 10
- Pages
- 1215-1225
- ISSN
- 1465-7392 (ISSN-L)
- 1476-4679
- OpenAlex
- W2892339961
- Cited by
- 162
- References
- 3
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-fluorophore biosensors for sensitive and multiplexed detection of signalling activities. https://app.cochat.ai/papers/10.1038/s41556-018-0200-6
- The paper
- Mehta, S., Zhang, Y., Roth, R. H., Zhang, J.-F., Mo, A., Tenner, B., Huganir, R. L., & Zhang, J. (2018). Single-fluorophore biosensors for sensitive and multiplexed detection of signalling activities. Nature Cell Biology. https://doi.org/10.1038/s41556-018-0200-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.