The DOI matches its Crossref record.
Efficient electrical detection of mid-infrared graphene plasmons at room temperature
Open accessAbstract
Optical excitation and subsequent decay of graphene plasmons can produce a significant increase in charge-carrier temperature. An efficient method to convert this temperature elevation into electrical signals can enable important mid-infrared applications. However, the modest thermoelectric coefficient and weak temperature dependence of carrier transport in graphene hinder this goal. Here, we demonstrate mid-infrared graphene detectors consisting of arrays of plasmonic resonators interconnected by quasi-one-dimensional nanoribbons. Localized barriers associated with disorder in the nanoribbons produce a dramatic temperature dependence of carrier transport, thus enabling the electrical detection of plasmon decay in the nearby graphene resonators. Our device has a subwavelength footprint of 5 × 5 μm2 and operates at 12.2 μm with an external responsivity of 16 mA W–1 and a low noise-equivalent power of 1.3 nW Hz–1/2 at room temperature. It is fabricated using large-scale graphene and possesses a simple two-terminal geometry, representing an essential step towards the realization of an on-chip graphene mid-infrared detector array.A system of patterned graphene nanoresonators/nanoribbons can be used as an efficient mid-infrared detector, based on plasmonic resonant absorption and subsequent carrier thermalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Unipolar barrier photodetectors based on van der Waals heterostructures
Chen, Y., Wang, Y., Wang, Z., Gu, Y., Ye, Y., Chai, X., Ye, J., Chen, Y., Xie, R., Zhou, Y., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00586-w · Cited by 604
Photodetectors of 2D Materials from Ultraviolet to Terahertz Waves
Qiu, Q., & Huang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008126 · Cited by 582
Semimetals for high-performance photodetection
Liu, J., Xia, F., Xiao, D., García de Abajo, F. J., & Sun, D. (2020) · Nature Materials · doi:10.1038/s41563-020-0715-7 · Cited by 326
Self-citationMid-infrared semimetal polarization detectors with configurable polarity transition
Wei, J., Xu, C., Dong, B., Qiu, C.-W., & Lee, C. (2021) · Nature Photonics · doi:10.1038/s41566-021-00819-6 · Cited by 213
Yang, K., Kang, S., Wu, X., Liu, B., Sun, C., & Wang, Y. (2023) · Applied Physics Letters · doi:10.1063/5.0168376 · Cited by 6
Metadata
- Authors
- Guo, Q., Yu, R., Li, C., Yuan, S., Deng, B., García de Abajo, F. J., & Xia, F.
- Venue
- Nature Materials
- Published
- 2018-08-27
- Volume
- 17
- Issue
- 11
- Pages
- 986-992
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W2803848478
- Cited by
- 165
- References
- 0
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient electrical detection of mid-infrared graphene plasmons at room temperature. https://app.cochat.ai/papers/10.1038/s41563-018-0157-7
- The paper
- Guo, Q., Yu, R., Li, C., Yuan, S., Deng, B., García de Abajo, F. J., & Xia, F. (2018). Efficient electrical detection of mid-infrared graphene plasmons at room temperature. Nature Materials. https://doi.org/10.1038/s41563-018-0157-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.