Label-free biomedical optical imaging
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Label-free optical imaging employs natural and non-destructive approaches to visualize biomedical samples for both biological assays and clinical diagnosis. At present, this field revolves around multiple technology-oriented communities, each with a specific focus on a particular modality, despite the existence of shared challenges and applications. As a result, biologists or clinical researchers who require label-free imaging are often not aware of the most appropriate modality to use. This Review presents a comprehensive overview of, and comparison among, different label-free imaging modalities and discusses common challenges and applications. We expect this Review to facilitate collaborative interactions between imaging communities, push the field forwards and foster technological advancements and biophysical discoveries, as well as facilitate new avenues in clinical detection, diagnosis and monitoring of diseases. This Review covers a comparison between various label-free biomedical imaging techniques, their advantages over label-based methods and relevant applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flat optics with designer metasurfaces
Yu, N., & Capasso, F. (2014) · Nature Materials · doi:10.1038/nmat3839 · Cited by 5,984 · cited 1×
“Specifically, recent advances in optical metasurfaces 96,97 might bring to new efficient on-chip implementations of various label-free imaging techniques.”
BackgroundPhotoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 6×
“Photoacoustic tomography (PAT) 60 provides 3D imaging based on the photoacoustic effect.”
BackgroundInfluentialSelf-citationLabel-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He, C., Tsai, J. C., Kang, J. X., & Xie, X. S. (2008) · Science · doi:10.1126/science.1165758 · Cited by 2,255
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854 · cited 6×
“Photoacoustic tomography (PAT) 60 provides 3D imaging based on the photoacoustic effect.”
BackgroundInfluentialSelf-citationPerformance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Quantitative phase imaging in biomedicine
Park, Y., Depeursinge, C., & Popescu, G. (2018) · Nature Photonics · doi:10.1038/s41566-018-0253-x · Cited by 1,802
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 2×
“PAT is capable of in vivo 61,66–69 and in vitro 70 imaging at multiple length scales, ranging from subcellular organelles to human organs or small-animal organisms 71 with the same contrast origin, as shown in Fig.”
BackgroundMethodSelf-citationThree-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering
Zumbusch, A., Holtom, G. R., & Xie, X. S. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4142 · Cited by 1,626
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364 · cited 1×
“…of OCT, including ophthalmic imaging 15–17 , coronary artery disease detection 18,19 , intraoperative optical biopsy in cancer detection 20–22 , endoscopic evaluation of the gastrointestinal tract 23,24 , skin imaging in dermatology 25–27 and blood flow imaging in vivo 28,29 , are…”
BackgroundSelf-citationAligned Collagen Is a Prognostic Signature for Survival in Human Breast Carcinoma
Conklin, M. W., Eickhoff, J. C., Riching, K. M., Pehlke, C. A., Eliceiri, K. W., Provenzano, P. P., Friedl, A., & Keely, P. J. (2011) · The American Journal of Pathology · doi:10.1016/j.ajpath.2010.11.076 · Cited by 1,285
Metadata
- Authors
- Shaked, N. T., Boppart, S. A., Wang, L. V., & Popp, J.
- Venue
- Nature Photonics
- Published
- 2023-11-16
- Volume
- 17
- Issue
- 12
- Pages
- 1031-1041
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W4388735543
- Cited by
- 161
- References
- 95
- FWCI
- 23.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-free biomedical optical imaging. https://app.cochat.ai/papers/10.1038/s41566-023-01299-6
- The paper
- Shaked, N. T., Boppart, S. A., Wang, L. V., & Popp, J. (2023). Label-free biomedical optical imaging. Nature Photonics. https://doi.org/10.1038/s41566-023-01299-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.