Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 440

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Low-loss plasmon-assisted electro-optic modulator

Open access
Haffner, Christian, Chelladurai, Daniel, Fedoryshyn, Yuriy, Josten, Arne, Baeuerle, Benedikt, Heni, Wolfgang, Watanabe, Tatsuhiko, Cui, Tong, Cheng, Bojun, Saha, Soham, Elder, Delwin L., Dalton, Larry. R., Boltasseva, Alexandra, Shalaev, Vladimir M., Kinsey, Nathaniel, Leuthold, Juerg·2018·Nature

Abstract

For nearly two decades, researchers in the field of plasmonics1—which studies the coupling of electromagnetic waves to the motion of free electrons near the surface of a metal2—have sought to realize subwavelength optical devices for information technology3–6, sensing7,8, nonlinear optics9,10, optical nanotweezers11 and biomedical applications12. However, the electron motion generates heat through ohmic losses. Although this heat is desirable for some applications such as photo-thermal therapy, it is a disadvantage in plasmonic devices for sensing and information technology13 and has led to a widespread view that plasmonics is too lossy to be practical. Here we demonstrate that the ohmic losses can be bypassed by using ‘resonant switching’. In the proposed approach, light is coupled to the lossy surface plasmon polaritons only in the device’s off state (in resonance) in which attenuation is desired, to ensure large extinction ratios between the on and off states and allow subpicosecond switching. In the on state (out of resonance), destructive interference prevents the light from coupling to the lossy plasmonic section of a device. To validate the approach, we fabricated a plasmonic electro-optic ring modulator. The experiments confirm that low on-chip optical losses, operation at over 100 gigahertz, good energy efficiency, low thermal drift and a compact footprint can be combined in a single device. Our result illustrates that plasmonics has the potential to enable fast, compact on-chip sensing and communications technologies. Ohmic losses in plasmonic devices can be reduced by exploiting ‘resonant switching’, in which light couples to surface plasmon polaritons only when in resonance and bypasses them otherwise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-018-0031-4

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 440

Metadata

Authors
Haffner, C., Chelladurai, D., Fedoryshyn, Y., Josten, A., Baeuerle, B., Heni, W., Watanabe, T., Cui, T., Cheng, B., Saha, S., Elder, D. L., Dalton, L. R., Boltasseva, A., Shalaev, V. M., Kinsey, N., & Leuthold, J.
Venue
Nature
Published
2018-04
Volume
556
Issue
7702
Pages
483-486
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2798125601
Cited by
440
References
7
FWCI
19.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-loss plasmon-assisted electro-optic modulator. https://app.cochat.ai/papers/10.1038/s41586-018-0031-4
The paper
Haffner, C., Chelladurai, D., Fedoryshyn, Y., Josten, A., Baeuerle, B., Heni, W., Watanabe, T., Cui, T., Cheng, B., Saha, S., Elder, D. L., Dalton, L. R., Boltasseva, A., Shalaev, V. M., Kinsey, N., & Leuthold, J. (2018). Low-loss plasmon-assisted electro-optic modulator. Nature. https://doi.org/10.1038/s41586-018-0031-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.