Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Video-based AI for beat-to-beat assessment of cardiac function

Open access

Published version of a preprint

Abstract

Accurate assessment of cardiac function is crucial for the diagnosis of cardiovascular disease 1, screening for cardiotoxicity 2 and decisions regarding the clinical management of patients with a critical illness 3. However, human assessment of cardiac function focuses on a limited sampling of cardiac cycles and has considerable inter-observer variability despite years of training 4,5. Here, to overcome this challenge, we present a video-based deep learning algorithm-EchoNet-Dynamic-that surpasses the performance of human experts in the critical tasks of segmenting the left ventricle, estimating ejection fraction and assessing cardiomyopathy. Trained on echocardiogram videos, our model accurately segments the left ventricle with a Dice similarity coefficient of 0.92, predicts ejection fraction with a mean absolute error of 4.1% and reliably classifies heart failure with reduced ejection fraction (area under the curve of 0.97). In an external dataset from another healthcare system, EchoNet-Dynamic predicts the ejection fraction with a mean absolute error of 6.0% and classifies heart failure with reduced ejection fraction with an area under the curve of 0.96. Prospective evaluation with repeated human measurements confirms that the model has variance that is comparable to or less than that of human experts. By leveraging information across multiple cardiac cycles, our model can rapidly identify subtle changes in ejection fraction, is more reproducible than human evaluation and lays the foundation for precise diagnosis of cardiovascular disease in real time. As a resource to promote further innovation, we also make publicly available a large dataset of 10,030 annotated echocardiogram videos.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41586-020-2145-8

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Research works printed but not linked: 1

  1. Chen, L.-C., Papandreou, G., Schroff, F. & Adam, H. Rethinking atrous convolution for semantic image segmentation. Preprint at https://arxiv.org/abs/1706.05587 (2017). · arXiv

Cited by

See all 1,153

Metadata

Authors
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y.
Affiliations
  • Stanford Medicine (US)
  • Stanford University (US)
  • Cedars-Sinai Medical Center (US)
Corresponding author
  • Ouyang, David
  • Zou, James Y.
Venue
Nature
Published
2020-03-25
Volume
580
Issue
7802
Pages
252-256
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W3013692475
Cited by
1,153
References
41
Citations by year
2026: 263 · 2025: 276 · 2024: 212 · 2023: 172 · 2022: 122 · 2021: 85 · 2020: 22
FWCI
62.03
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature (publishedVersion)
  • medRxiv (acceptedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
  • National Science Foundation (1763191)
  • American College of Cardiology Foundation
  • National Institutes of Health (1r21md012867-01, R21 MD012867-01)
  • National Institute on Aging (P30AG059307)
  • National Heart, Lung, and Blood Institute (F32 HL149298)
  • National Institute on Minority Health and Health Disparities (R21 MD012867)
  • Stanford Cardiovascular Institute, School of Medicine, Stanford University
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
EchoNet-Dynamic, echocardiography, left ventricle segmentation, ejection fraction estimation, heart failure with reduced ejection fraction, cardiomyopathy classification, interobserver variability, cardiovascular disease diagnosis
MeSH terms
Deep Learning, Atrial Fibrillation, Echocardiography, Heart, Heart Diseases, Heart Failure, Hospitals, Humans, Models, Cardiovascular, Prospective Studies, Video Recording, Reproducibility of Results, Ventricular Function, Left, Datasets as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Video-based AI for beat-to-beat assessment of cardiac function. https://app.cochat.ai/papers/10.1038/s41586-020-2145-8
The paper
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y. (2020). Video-based AI for beat-to-beat assessment of cardiac function. Nature. https://doi.org/10.1038/s41586-020-2145-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.