Detection of metastable electronic states by Penning trap mass spectrometry
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
State-of-the-art optical clocks 1 achieve precisions of 10 −18 or better using ensembles of atoms in optical lattices 2 , 3 or individual ions in radio-frequency traps 4 , 5 . Promising candidates for use in atomic clocks are highly charged ions 6 (HCIs) and nuclear transitions 7 , which are largely insensitive to external perturbations and reach wavelengths beyond the optical range 8 that are accessible to frequency combs 9 . However, insufficiently accurate atomic structure calculations hinder the identification of suitable transitions in HCIs. Here we report the observation of a long-lived metastable electronic state in an HCI by measuring the mass difference between the ground and excited states in rhenium, providing a non-destructive, direct determination of an electronic excitation energy. The result is in agreement with advanced calculations. We use the high-precision Penning trap mass spectrometer PENTATRAP to measure the cyclotron frequency ratio of the ground state to the metastable state of the ion with a precision of 10 −11 —an improvement by a factor of ten compared with previous measurements 10 , 11 . With a lifetime of about 130 days, the potential soft-X-ray frequency reference at 4.96 × 10 16 hertz (corresponding to a transition energy of 202 electronvolts) has a linewidth of only 5 × 10 −8 hertz and one of the highest electronic quality factors (10 24 ) measured experimentally so far. The low uncertainty of our method will enable searches for further soft-X-ray clock transitions 8 , 12 in HCIs, which are required for precision studies of fundamental physics 6 . Penning trap mass spectrometry is used to measure the electronic transition energy from a long-lived metastable state to the ground state in highly charged rhenium ions with a precision of 10 −11 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
A parts-per-billion measurement of the antiproton magnetic moment
Smorra, C., Sellner, S., Borchert, M. J., Harrington, J. A., Higuchi, T., Nagahama, H., Tanaka, T., Mooser, A., Schneider, G., Bohman, M., et al. (2017) · Nature · doi:10.1038/nature24048 · Cited by 149
Self-citation
Cited by
Muniz, J. A., Young, D. J., Cline, J. R. K., & Thompson, J. K. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023152 · Cited by 38
High-Precision Determination of g Factors and Masses of Ne209+ and Ne229+
Heiße, F., Door, M., Sailer, T., Filianin, P., Herkenhoff, J., König, C. M., Kromer, K., Lange, D., Morgner, J., Rischka, A., et al. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.253002 · Cited by 18
Self-citationMcMahon, B., & Sawyer, B. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.014005 · Cited by 12
Metadata
- Authors
- Schüssler, R. X., Bekker, H., Braß, M., Cakir, H., Crespo López-Urrutia, J. R., Door, M., Filianin, P., Harman, Z., Haverkort, M. W., Huang, W. J., Indelicato, P., Keitel, C. H., König, C. M., Kromer, K., Müller, M., Novikov, Y. N., Rischka, A., Schweiger, C., Sturm, S., Ulmer, S., Eliseev, S., & Blaum, K.
- Venue
- Nature
- Published
- 2020-05-06
- Volume
- 581
- Issue
- 7806
- Pages
- 42-46
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W3023945135
- Cited by
- 48
- References
- 10
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of metastable electronic states by Penning trap mass spectrometry. https://app.cochat.ai/papers/10.1038/s41586-020-2221-0
- The paper
- Schüssler, R. X., Bekker, H., Braß, M., Cakir, H., Crespo López-Urrutia, J. R., Door, M., Filianin, P., Harman, Z., Haverkort, M. W., Huang, W. J., Indelicato, P., Keitel, C. H., König, C. M., Kromer, K., Müller, M., Novikov, Y. N., Rischka, A., Schweiger, C., Sturm, S., . . . Blaum, K. (2020). Detection of metastable electronic states by Penning trap mass spectrometry. Nature. https://doi.org/10.1038/s41586-020-2221-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.