Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Graphene-based Josephson junction microwave bolometer

Open access
Lee, Gil-Ho, Efetov, Dmitri K., Jung, Woochan, Ranzani, Leonardo, Walsh, Evan D., Ohki, Thomas A., Taniguchi, Takashi, Watanabe, Kenji, Kim, Philip, Englund, Dirk, Fong, Kin Chung · 2020 · Nature

Abstract

Sensitive microwave detectors are essential in radioastronomy1, dark-matter axion searches2 and superconducting quantum information science3,4. The conventional strategy to obtain higher-sensitivity bolometry is the nanofabrication of ever smaller devices to augment the thermal response5–7. However, it is difficult to obtain efficient photon coupling and to maintain the material properties in a device with a large surface-to-volume ratio owing to surface contamination. Here we present an ultimately thin bolometric sensor based on monolayer graphene. To utilize the minute electronic specific heat and thermal conductivity of graphene, we develop a superconductor–graphene–superconductor Josephson junction8–13 bolometer embedded in a microwave resonator with a resonance frequency of 7.9 gigahertz and over 99 per cent coupling efficiency. The dependence of the Josephson switching current on the operating temperature, charge density, input power and frequency shows a noise-equivalent power of 7 × 10−19 watts per square-root hertz, which corresponds to an energy resolution of a single 32-gigahertz photon14, reaching the fundamental limit imposed by intrinsic thermal fluctuations at 0.19 kelvin. Our results establish that two-dimensional materials could enable the development of bolometers with the highest sensitivity allowed by the laws of thermodynamics. An ultimately thin microwave bolometric sensor based on a superconductor–graphene–superconductor Josephson junction with monolayer graphene has a sensitivity approaching the fundamental limit imposed by intrinsic thermal fluctuations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-020-2752-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Lee, G.-H., Efetov, D. K., Jung, W., Ranzani, L., Walsh, E. D., Ohki, T. A., Taniguchi, T., Watanabe, K., Kim, P., Englund, D., & Fong, K. C.
Venue
Nature
Published
2020-09-30
Volume
586
Issue
7827
Pages
42-46
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2973122102
Cited by
160
References
1
FWCI
9.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Graphene-based Josephson junction microwave bolometer. https://app.cochat.ai/papers/10.1038/s41586-020-2752-4
The paper
Lee, G.-H., Efetov, D. K., Jung, W., Ranzani, L., Walsh, E. D., Ohki, T. A., Taniguchi, T., Watanabe, K., Kim, P., Englund, D., & Fong, K. C. (2020). Graphene-based Josephson junction microwave bolometer. Nature. https://doi.org/10.1038/s41586-020-2752-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.