The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Graphene-based Josephson junction microwave bolometer
Open accessAbstract
Sensitive microwave detectors are essential in radioastronomy1, dark-matter axion searches2 and superconducting quantum information science3,4. The conventional strategy to obtain higher-sensitivity bolometry is the nanofabrication of ever smaller devices to augment the thermal response5–7. However, it is difficult to obtain efficient photon coupling and to maintain the material properties in a device with a large surface-to-volume ratio owing to surface contamination. Here we present an ultimately thin bolometric sensor based on monolayer graphene. To utilize the minute electronic specific heat and thermal conductivity of graphene, we develop a superconductor–graphene–superconductor Josephson junction8–13 bolometer embedded in a microwave resonator with a resonance frequency of 7.9 gigahertz and over 99 per cent coupling efficiency. The dependence of the Josephson switching current on the operating temperature, charge density, input power and frequency shows a noise-equivalent power of 7 × 10−19 watts per square-root hertz, which corresponds to an energy resolution of a single 32-gigahertz photon14, reaching the fundamental limit imposed by intrinsic thermal fluctuations at 0.19 kelvin. Our results establish that two-dimensional materials could enable the development of bolometers with the highest sensitivity allowed by the laws of thermodynamics. An ultimately thin microwave bolometric sensor based on a superconductor–graphene–superconductor Josephson junction with monolayer graphene has a sensitivity approaching the fundamental limit imposed by intrinsic thermal fluctuations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single microwave-photon detector using an artificial Λ-type three-level system
Inomata, K., Lin, Z., Koshino, K., Oliver, W. D., Tsai, J.-S., Yamamoto, T., & Nakamura, Y. (2016) · Nature Communications · doi:10.1038/ncomms12303 · Cited by 203
Cited by
Pham, P. V., Bodepudi, S. C., Shehzad, K., Liu, Y., Xu, Y., Yu, B., & Duan, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00735 · Cited by 708
The field-free Josephson diode in a van der Waals heterostructure
Wu, H., Wang, Y., Xu, Y., Sivakumar, P. K., Pasco, C., Filippozzi, U., Parkin, S. S. P., Zeng, Y.-J., McQueen, T., & Ali, M. N. (2022) · Nature · doi:10.1038/s41586-022-04504-8 · Cited by 391
Metadata
- Authors
- Lee, G.-H., Efetov, D. K., Jung, W., Ranzani, L., Walsh, E. D., Ohki, T. A., Taniguchi, T., Watanabe, K., Kim, P., Englund, D., & Fong, K. C.
- Venue
- Nature
- Published
- 2020-09-30
- Volume
- 586
- Issue
- 7827
- Pages
- 42-46
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2973122102
- Cited by
- 160
- References
- 1
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Graphene-based Josephson junction microwave bolometer. https://app.cochat.ai/papers/10.1038/s41586-020-2752-4
- The paper
- Lee, G.-H., Efetov, D. K., Jung, W., Ranzani, L., Walsh, E. D., Ohki, T. A., Taniguchi, T., Watanabe, K., Kim, P., Englund, D., & Fong, K. C. (2020). Graphene-based Josephson junction microwave bolometer. Nature. https://doi.org/10.1038/s41586-020-2752-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.