Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Integrated femtosecond pulse generator on thin-film lithium niobate

Open access
Yu, Mengjie, Barton III, David, Cheng, Rebecca, Reimer, Christian, Kharel, Prashanta, He, Lingyan, Shao, Linbo, Zhu, Di, Hu, Yaowen, Grant, Hannah R., Johansson, Leif, Okawachi, Yoshitomo, Gaeta, Alexander L., Zhang, Mian, Lončar, Marko · 2022 · Nature

Abstract

Optical isolators are indispensable components of almost any optical system and are used to protect a laser from unwanted reflections for phase-stable coherent operation. The emergence of chip-scale optical systems, powered by semiconductor lasers that are integrated on the same chip, has generated a demand for a fully integrated optical isolator. Conventional approaches, which rely on the use of magneto-optic materials to break Lorentz reciprocity, present substantial challenges in terms of material integration. Although alternative magnetic-free approaches have been explored, an integrated isolator with a low insertion loss, high isolation ratio, broad bandwidth and low power consumption on a monolithic material platform is yet to be achieved. Here we realize a non-reciprocal travelling-wave-based electro-optic isolator on thin-film lithium niobate. The isolator enables a maximum optical isolation of 48.0 dB with an on-chip insertion loss of 0.5 dB and uses a single-frequency microwave drive power of 21 dBm. The isolation ratio remains larger than 37 dB across a tunable optical wavelength range from 1,510 to 1,630 nm. We realize a hybrid distributed feedback laser–lithium niobate isolator module that successfully protects the single-mode operation and linewidth of the laser from reflection. Our result represents an important step towards a practical high-performance optical isolator on chip. An integrated electro-optic isolator on thin-film lithium niobate enables non-reciprocal isolation by microwave-driven travelling-wave phase modulation. The isolator exhibits a maximum optical isolation of 48.0 dB at around 1,553 nm and an on-chip insertion loss of 0.5 dB.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-022-05345-1

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Cited by

See all 278

Metadata

Authors
Yu, M., Barton III, D., Cheng, R., Reimer, C., Kharel, P., He, L., Shao, L., Zhu, D., Hu, Y., Grant, H. R., Johansson, L., Okawachi, Y., Gaeta, A. L., Zhang, M., & Lončar, M.
Venue
Nature
Published
2022-11-16
Volume
612
Issue
7939
Pages
252-258
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4309409773
Cited by
278
References
49
FWCI
22.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integrated femtosecond pulse generator on thin-film lithium niobate. https://app.cochat.ai/papers/10.1038/s41586-022-05345-1
The paper
Yu, M., Barton III, D., Cheng, R., Reimer, C., Kharel, P., He, L., Shao, L., Zhu, D., Hu, Y., Grant, H. R., Johansson, L., Okawachi, Y., Gaeta, A. L., Zhang, M., & Lončar, M. (2022). Integrated femtosecond pulse generator on thin-film lithium niobate. Nature. https://doi.org/10.1038/s41586-022-05345-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.