One-step nanoscale expansion microscopy reveals individual protein shapes
Open accessPublished version of a preprint
Abstract
Abstract Fluorescence imaging is one of the most versatile and widely-used tools in biology 1 . Although techniques to overcome the diffraction barrier were introduced more than two decades ago, and the nominal attainable resolution kept improving 2, 3 , fluorescence microscopy still fails to image the morphology of single proteins or small molecular complexes, either purified or in a cellular context 4, 5 . Here we report a solution to this problem, in the form of o ne-step n anoscale e xpansion (ONE) microscopy. We combined the 10-fold axial expansion of the specimen (1000-fold by volume) with a fluorescence fluctuation analysis 6, 7 to enable the description of cultured cells, tissues, viral particles, molecular complexes and single proteins. At the cellular level, using immunostaining, our technology revealed detailed nanoscale arrangements of synaptic proteins, including a quasi-regular organisation of PSD95 clusters. At the single molecule level, upon main chain fluorescent labelling, we could visualise the shape of individual membrane and soluble proteins. Moreover, conformational changes undergone by the ∼17 kDa protein calmodulin upon Ca 2+ binding were readily observable. We also imaged and classified molecular aggregates in cerebrospinal fluid samples from Parkinson’s Disease (PD) patients, which represents a promising new development towards improved PD diagnosis. ONE microscopy is compatible with conventional microscopes and can be performed with the software we provide here as a free, open-source package. This technology bridges the gap between high-resolution structural biology techniques and light microscopy, and provides a new avenue for discoveries in biology and medicine.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Highly accurate protein structure prediction with AlphaFold
Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03819-2 · Cited by 43,764 · see citing works
Protein complex prediction with AlphaFold-Multimer
Evans, R., O’Neill, M., Pritzel, A., Antropova, N., Senior, A., Green, T., Žídek, A., Bates, R., Blackwell, S., Yim, J., et al. (2021) · doi:10.1101/2021.10.04.463034 · Cited by 3,808 · see citing works
Molecular anatomy of a trafficking organelle
Takamori, S., Holt, M., Stenius, K., Lemke, E. A., Grønborg, M., Riedel, D., Urlaub, H., Schenck, S., Brügger, B., Ringler, P., et al. (2006) · Cell · doi:10.1016/j.cell.2006.10.030 · Cited by 2,373 · see citing works
Mollenhauer, B., Cullen, V., Kahn, I., Krastins, B., Outeiro, T. F., Pepivani, I., Ng, J., Schulz-Schaeffer, W., Kretzschmar, H. A., McLean, P. J., et al. (2008) · Experimental Neurology · doi:10.1016/j.expneurol.2008.06.004 · Cited by 382 · see citing works
Self-citation‘MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution’
Eilers, Y., Ta, H., Gwosch, K. C., Balzarotti, F., & Hell, S. W. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1801672115 · Cited by 188 · see citing works
Mutch, S. A., Kensel-Hammes, P., Gadd, J. C., Fujimoto, B. S., Allen, R. W., Schiro, P. G., Lorenz, R. M., Kuyper, C. L., Kuo, J. S., Bajjalieh, S. M., et al. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3805-10.2011 · Cited by 185 · see citing works
Flagged first, then by citations
- Authors
- Shaib, A. H., Chouaib, A. A., Chowdhury, R., Altendorf, J., Mihaylov, D., Zhang, C., Krah, D., Imani, V., Spencer, R. K. W., Georgiev, S. V., Mougios, N., Monga, M., Reshetniak, S., Mimoso, T., Chen, H., Fatehbasharzad, P., Crzan, D., Saal, K.-A., Alawieh, M. M., Alawar, N., Eilts, J., Kang, J., Soleimani, A., Müller, M., Pape, C., Alvarez, L., Trenkwalder, C., Mollenhauer, B., Outeiro, T. F., Köster, S., Preobraschenski, J., Becherer, U., Moser, T., Boyden, E. S., Aricescu, A. R., Sauer, M., Opazo, F., & Rizzoli, S. O.
- Affiliations
- Universitätsmedizin Göttingen (DE)
- Saarland University (DE)
- MRC Laboratory of Molecular Biology (GB)
- Howard Hughes Medical Institute (US)
- University of Göttingen (DE)
- University of Würzburg (DE)
- German Center for Neurodegenerative Diseases (DE)
- Multiscale Bioimaging (DE)
- Corresponding author
- Shaib, Ali H.
- Rizzoli, Silvio O.
- ORCID
- Shaib, Ali H.
- Chouaib, Abed Alrahman
- Chowdhury, Rajdeep
- Altendorf, Jonas
- Mihaylov, Daniel
- Zhang, Chi
- Krah, Donatus
- Spencer, Russell K. W.
- Georgiev, Svilen Veselinov
- Mougios, Nikolaos
- Reshetniak, Sofiia
- Chen, Han
- Fatehbasharzad, Parisa
- Alawieh, Mohamad Mahdi
- Alawar, Nadia
- Eilts, Janna
- Kang, Jinyoung
- Soleimani, Alireza
- Müller, Marcus
- Pape, Constantin
- Alvarez, Luis
- Trenkwalder, Claudia
- Mollenhauer, Brit
- Outeiro, Tiago F.
- Köster, Sarah
- Preobraschenski, Julia
- Becherer, Ute
- Moser, Tobias
- Boyden, Edward S.
- Aricescu, A. Radu
- Sauer, Markus
- Opazo, Felipe
- Rizzoli, Silvio O.
- Venue
- Nature Biotechnology
- Published
- 2024-10-09
- Volume
- 43
- Issue
- 9
- Pages
- 1539-1547
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- PMC
- PMC7616833
- OpenAlex
- W4403253139
- Cited by
- 104
- References
- 6
- Citations by year
- 2026: 26 · 2025: 37 · 2024: 19 · 2023: 20 · 2022: 2
- FWCI
- 15.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Nature Biotechnology (publishedVersion, cc-by-nc-nd)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (publishedVersion, other-oa)
- DZNE Pub (submittedVersion, cc-by-nc-nd)
- GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (submittedVersion)
- Newcastle University ePrints (Newcastle Univesity) (cc-by-nc-nd)
- Funders
- Deutsche Forschungsgemeinschaft (SFB1286/A03/B02/C06/Z04, SFB894/A9)
- RCUK | MRC | Medical Research Foundation (MR/L009609/1)
- RCUK | Medical Research Council (MR/L009609/1, MC_EX_MR/T046279/1, MC_UP_1201/15)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- expansion microscopy, protein shape, fluorescence intensity fluctuations, calmodulin, calcium binding, protein conformational change, membrane proteins, soluble protein, protein aggregates, Parkinson's disease, cerebrospinal fluid, super-resolution imaging
- MeSH terms
- Calcium, Calmodulin, Humans, Microscopy, Fluorescence, Parkinson Disease, Protein Conformation, Proteins, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review