Orthogonal fluorescent chemogenetic reporters for multicolor imaging
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Spectrally separated fluorophores allow the observation of multiple targets simultaneously inside living cells, leading to a deeper understanding of the molecular interplay that regulates cell function and fate. Chemogenetic systems combining a tag and a synthetic fluorophore provide certain advantages over fluorescent proteins since there is no requirement for chromophore maturation. Here, we present the engineering of a set of spectrally orthogonal fluorogen-activating tags based on the fluorescence-activating and absorption shifting tag (FAST) that are compatible with two-color, live-cell imaging. The resulting tags, greenFAST and redFAST, demonstrate orthogonality not only in their fluorogen recognition capabilities, but also in their one- and two-photon absorption profiles. This pair of orthogonal tags allowed the creation of a two-color cell cycle sensor capable of detecting very short, early cell cycles in zebrafish development and the development of split complementation systems capable of detecting multiple protein–protein interactions by live-cell fluorescence microscopy. The fluorescent chemogenetic reporters greenFAST and redFAST were engineered by protein engineering. They display orthogonal fluorogen recognition and spectral properties allowing efficient multicolor imaging of proteins in live cells and organisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Cited by
Caveat fluorophore: an insiders’ guide to small-molecule fluorescent labels
Grimm, J. B., & Lavis, L. D. (2022) · Nature Methods · doi:10.1038/s41592-021-01338-6 · Cited by 274
Bottone, S., Joliot, O., Cakil, Z. V., El Hajji, L., Rakotoarison, L.-M., Boncompain, G., Perez, F., & Gautier, A. (2023) · Nature Methods · doi:10.1038/s41592-023-01988-8 · Cited by 48
Self-citationA fluorogenic complementation tool kit for interrogating lipid droplet–organelle interaction
Li, X., Gamuyao, R., Wu, M.-L., Cho, W. J., King, S. V., Petersen, R. A., Stabley, D. R., Lindow, C., Climer, L. K., Shirinifard, A., et al. (2024) · Journal of Cell Biology · doi:10.1083/jcb.202311126 · Cited by 31
Self-citation(2025) · doi:10.1038/s41467-025-62241-8 · Cited by 5
Metadata
- Authors
- Tebo, A. G., Moeyaert, B., Thauvin, M., Carlon-Andres, I., Böken, D., Volovitch, M., Padilla-Parra, S., Dedecker, P., Vriz, S., & Gautier, A.
- Venue
- Nature Chemical Biology
- Published
- 2020-08-10
- Volume
- 17
- Issue
- 1
- Pages
- 30-38
- ISSN
- 1552-4450 (ISSN-L)
- 1552-4469
- OpenAlex
- W3048007410
- Cited by
- 82
- References
- 1
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Orthogonal fluorescent chemogenetic reporters for multicolor imaging. https://app.cochat.ai/papers/10.1038/s41589-020-0611-0
- The paper
- Tebo, A. G., Moeyaert, B., Thauvin, M., Carlon-Andres, I., Böken, D., Volovitch, M., Padilla-Parra, S., Dedecker, P., Vriz, S., & Gautier, A. (2021). Orthogonal fluorescent chemogenetic reporters for multicolor imaging. Nature Chemical Biology. https://doi.org/10.1038/s41589-020-0611-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.