Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Self-citationSpontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975 · cited 1×
“The cornerstone of this procedure is the electrical isolation of the pulmonary veins (PVs) 3 .”
McHorney, C. A., Ware, J. E., Rachel Lu, J. F., & Sherbourne, C. D. (1994) · Medical Care · doi:10.1097/00005650-199401000-00004 · Cited by 4,458
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765 · cited 2×
“Catheter-based ablation is an effective and safe treatment for patients with AF 1,2 .”
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationApproaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
Reddy, V. Y., Gerstenfeld, E. P., Natale, A., Whang, W., Cuoco, F. A., Patel, C., Mountantonakis, S. E., Gibson, D. N., Harding, J. D., Ellis, C. R., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307291 · Cited by 970 · cited 1×
“Procedural times with the investigational device were favorable also when compared to single-shot PFA technologies, typically ranging between 106 min and 145 min 26,37 .”
Self-citationMembrane Electroporation and Electropermeabilization: Mechanisms and Models
Kotnik, T., Rems, L., Tarek, M., & Miklavčič, D. (2019) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-052118-115451 · Cited by 813 · cited 1×
“Pulsed field ablation (PFA), a non-thermal energy source, ablates tissue by using microsecond pulses of electric fields to destabilize cell membranes 12,13 .”
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Verma, A., Haines, D. E., Boersma, L. V., Sood, N., Natale, A., Marchlinski, F. E., Calkins, H., Sanders, P., Packer, D. L., Kuck, K.-H., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.063988 · Cited by 613 · cited 3×
“…of using pulsed field on the posterior wall, an energy source shown to avoid the risk of thermal injury to adjacent organs, such as the esophagus 26 Trial success with respect to effectiveness was defined as non-inferiority of the primary effectiveness endpoint based on binomial proportions…”
Self-citationCell death due to electroporation – A review
Batista Napotnik, T., Polajžer, T., & Miklavčič, D. (2021) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2021.107871 · Cited by 542
Metadata
- Authors
- Anter, E., Mansour, M., Nair, D. G., Sharma, D., Taigen, T. L., Neuzil, P., Kiehl, E. L., Kautzner, J., Osorio, J., Mountantonakis, S., Natale, A., Hummel, J. D., Amin, A. K., Siddiqui, U. R., Harlev, D., Hultz, P., Liu, S., Onal, B., Tarakji, K. G., Reddy, V. Y., SPHERE PER-AF Investigators, & Reddy, V. Y.
- Venue
- Nature Medicine
- Published
- 2024-05-17
- Volume
- 30
- Issue
- 8
- Pages
- 2303-2310
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W4396994038
- Cited by
- 169
- References
- 41
- FWCI
- 45.39
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial. https://app.cochat.ai/papers/10.1038/s41591-024-03022-6
- The paper
- Anter, E., Mansour, M., Nair, D. G., Sharma, D., Taigen, T. L., Neuzil, P., Kiehl, E. L., Kautzner, J., Osorio, J., Mountantonakis, S., Natale, A., Hummel, J. D., Amin, A. K., Siddiqui, U. R., Harlev, D., Hultz, P., Liu, S., Onal, B., Tarakji, K. G., . . . Reddy, V. Y. (2024). Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial. Nature Medicine. https://doi.org/10.1038/s41591-024-03022-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.