CoChat

Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial

Open access
Anter, Elad, Mansour, Moussa, Nair, Devi G., Sharma, Dinesh, Taigen, Tyler L., Neuzil, Petr, Kiehl, Erich L., Kautzner, Josef, Osorio, Jose, Mountantonakis, Stavros, Natale, Andrea, Hummel, John D., Amin, Anish K., Siddiqui, Usman R., Harlev, Doron, Hultz, Paul, Liu, Shufeng, Onal, Birce, Tarakji, Khaldoun G., Reddy, Vivek Y., SPHERE PER-AF Investigators, Reddy, Vivek Y. · 2024 · Nature Medicine
Cited by 169

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41591-024-03022-6

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Anter, E., Mansour, M., Nair, D. G., Sharma, D., Taigen, T. L., Neuzil, P., Kiehl, E. L., Kautzner, J., Osorio, J., Mountantonakis, S., Natale, A., Hummel, J. D., Amin, A. K., Siddiqui, U. R., Harlev, D., Hultz, P., Liu, S., Onal, B., Tarakji, K. G., Reddy, V. Y., SPHERE PER-AF Investigators, & Reddy, V. Y.
Venue
Nature Medicine
Published
2024-05-17
Volume
30
Issue
8
Pages
2303-2310
ISSN
  • 1078-8956 (ISSN-L)
  • 1546-170X
OpenAlex
W4396994038
Cited by
169
References
41
FWCI
45.39
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.