Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Randomized Ablation Strategies for the Treatment of Persistent Atrial Fibrillation: RASTA Study

Dixit, Sanjay, Marchlinski, Francis E., Lin, David, Callans, David J., Bala, Rupa, Riley, Michael P., Garcia, Fermin C., Hutchinson, Mathew D., Ratcliffe, Sarah J., Cooper, Joshua M., Verdino, Ralph J., Patel, Vickas V., Zado, Erica S., Cash, Nancy R., Killian, Tony, Tomson, Todd T., Gerstenfeld, Edward P.·2012·Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: The single-procedure efficacy of pulmonary vein isolation (PVI) is less than optimal in patients with persistent atrial fibrillation (AF). Adjunctive techniques have been developed to enhance single-procedure efficacy in these patients. We conducted a study to compare 3 ablation strategies in patients with persistent AF. Methods and Results—: Subjects were randomized as follows: arm 1, PVI + ablation of non-PV triggers identified using a stimulation protocol (standard approach); arm 2, standard approach + empirical ablation at common non-PV AF trigger sites (mitral annulus, fossa ovalis, eustachian ridge, crista terminalis, and superior vena cava); or arm 3, standard approach + ablation of left atrial complex fractionated electrogram sites. Patients were seen at 6 weeks, 6 months, and 1 year; transtelephonic monitoring was performed at each visit. Antiarrhythmic drugs were discontinued at 3 to 6 months. The primary study end point was freedom from atrial arrhythmias off antiarrhythmic drugs at 1 year after a single-ablation procedure. A total of 156 patients (aged 59±9 years; 136 males; AF duration, 47±50 months) participated (arm 1, 55 patients; arm 2, 50 patients; arm 3, 51 patients). Procedural outcomes (procedure, fluoroscopy, and PVI times) were comparable between the 3 arms. More lesions were required to target non-PV trigger sites than a complex fractionated electrogram (33±9 versus 22±9; P <0.001). The primary end point was achieved in 71 patients and was worse in arm 3 (29%) compared with arm 1 (49%; P =0.04) and arm 2 (58%; P =0.004). Conclusions—: These data suggest that additional substrate modification beyond PVI does not improve single-procedure efficacy in patients with persistent AF. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00379301.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.111.966226

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 281

Metadata

Authors
Dixit, S., Marchlinski, F. E., Lin, D., Callans, D. J., Bala, R., Riley, M. P., Garcia, F. C., Hutchinson, M. D., Ratcliffe, S. J., Cooper, J. M., Verdino, R. J., Patel, V. V., Zado, E. S., Cash, N. R., Killian, T., Tomson, T. T., & Gerstenfeld, E. P.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2012-04
Volume
5
Issue
2
Pages
287-294
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2132445458
Cited by
281
References
15
FWCI
10.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Ablation Strategies for the Treatment of Persistent Atrial Fibrillation: RASTA Study. https://app.cochat.ai/papers/10.1161/circep.111.966226
The paper
Dixit, S., Marchlinski, F. E., Lin, D., Callans, D. J., Bala, R., Riley, M. P., Garcia, F. C., Hutchinson, M. D., Ratcliffe, S. J., Cooper, J. M., Verdino, R. J., Patel, V. V., Zado, E. S., Cash, N. R., Killian, T., Tomson, T. T., & Gerstenfeld, E. P. (2012). Randomized Ablation Strategies for the Treatment of Persistent Atrial Fibrillation: RASTA Study. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.111.966226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.