Cryo-EM model validation recommendations based on outcomes of the 2019 EMDataResource challenge
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper describes outcomes of the 2019 Cryo-EM Model Challenge. The goals were to (1) assess the quality of models that can be produced from cryogenic electron microscopy (cryo-EM) maps using current modeling software, (2) evaluate reproducibility of modeling results from different software developers and users and (3) compare performance of current metrics used for model evaluation, particularly Fit-to-Map metrics, with focus on near-atomic resolution. Our findings demonstrate the relatively high accuracy and reproducibility of cryo-EM models derived by 13 participating teams from four benchmark maps, including three forming a resolution series (1.8 to 3.1 Å). The results permit specific recommendations to be made about validating near-atomic cryo-EM structures both in the context of individual experiments and structure data archives such as the Protein Data Bank. We recommend the adoption of multiple scoring parameters to provide full and objective annotation and assessment of the model, reflective of the observed cryo-EM map density.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MolProbity: More and better reference data for improved all‐atom structure validation
Williams, C. J., Headd, J. J., Moriarty, N. W., Prisant, M. G., Videau, L. L., Deis, L. N., Verma, V., Keedy, D. A., Hintze, B. J., Chen, V. B., et al. (2018) · Protein Science · doi:10.1002/pro.3330 · Cited by 4,599
Self-citationRosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Self-citationKühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Protein Data Bank: the single global archive for 3D macromolecular structure data
wwPDB consortium, Burley, S. K., Berman, H. M., Bhikadiya, C., Bi, C., Chen, L., Costanzo, L. D., Christie, C., Duarte, J. M., Dutta, S., et al. (2019) · Nucleic Acids Research · doi:10.1093/nar/gky949 · Cited by 1,163
Self-citationMariani, V., Biasini, M., Barbato, A., & Schwede, T. (2013) · Bioinformatics · doi:10.1093/bioinformatics/btt473 · Cited by 1,138
LGA: a method for finding 3D similarities in protein structures
Zemla, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg571 · Cited by 1,069
EMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
Self-citationOutcome of the first electron microscopy validation task force meeting
Henderson, R., Sali, A., Baker, M. L., Carragher, B., Devkota, B., Downing, K. H., Egelman, E. H., Feng, Z., Frank, J., Grigorieff, N., et al. (2012) · Structure · doi:10.1016/j.str.2011.12.014 · Cited by 505
Self-citationCryo‐EM model validation using independent map reconstructions
DiMaio, F., Zhang, J., Chiu, W., & Baker, D. (2013) · Protein Science · doi:10.1002/pro.2267 · Cited by 72
Self-citation
Cited by
Improvement of cryo-EM maps by simultaneous local and non-local deep learning
He, J., Li, T., & Huang, S.-Y. (2023) · Nature Communications · doi:10.1038/s41467-023-39031-1 · Cited by 212
“5) is used as a metric to measure the relative accuracy of the map 42 .”
Low-Temperature Plasma for Biology, Hygiene, and Medicine: Perspective and Roadmap
Laroussi, M., Bekeschus, S., Keidar, M., Bogaerts, A., Fridman, A., Lu, X., Ostrikov, K., Hori, M., Stapelmann, K., Miller, V., et al. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2021.3135118 · Cited by 174
Better, Faster, Cheaper: Recent Advances in Cryo–Electron Microscopy
Chua, E. Y. D., Mendez, J. H., Rapp, M., Ilca, S. L., Tan, Y. Z., Maruthi, K., Kuang, H., Zimanyi, C. M., Cheng, A., Eng, E. T., et al. (2022) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-032620-110705 · Cited by 159
Cryo-EM structure and B-factor refinement with ensemble representation
Beton, J. G., Mulvaney, T., Cragnolini, T., & Topf, M. (2024) · Nature Communications · doi:10.1038/s41467-023-44593-1 · Cited by 30
Automated multiconformer model building for X-ray crystallography and cryo-EM
Wankowicz, S. A., Ravikumar, A., Sharma, S., Riley, B., Raju, A., Hogan, D. W., Flowers, J., van den Bedem, H., Keedy, D. A., & Fraser, J. S. (2024) · eLife · doi:10.7554/elife.90606 · Cited by 28
Self-citation
Metadata
- Authors
- Lawson, C. L., Kryshtafovych, A., Adams, P. D., Afonine, P. V., Baker, M. L., Barad, B. A., Bond, P., Burnley, T., Cao, R., Cheng, J., Chojnowski, G., Cowtan, K., Dill, K. A., DiMaio, F., Farrell, D. P., Fraser, J. S., Herzik, M. A., Hoh, S. W., Hou, J., Hung, L.-W., Igaev, M., Joseph, A. P., Kihara, D., Kumar, D., Mittal, S., Monastyrskyy, B., Olek, M., Palmer, C. M., Patwardhan, A., Perez, A., Pfab, J., Pintilie, G. D., Richardson, J. S., Rosenthal, P. B., Sarkar, D., Schäfer, L. U., Schmid, M. F., Schröder, G. F., Shekhar, M., Si, D., Singharoy, A., Terashi, G., Terwilliger, T. C., Vaiana, A., Wang, L., Wang, Z., Wankowicz, S. A., Williams, C. J., Winn, M., Wu, T., Yu, X., Zhang, K., Berman, H. M., & Chiu, W.
- Venue
- Nature Methods
- Published
- 2021-02
- Volume
- 18
- Issue
- 2
- Pages
- 156-164
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W3127623024
- Cited by
- 113
- References
- 9
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.