The DOI matches its Crossref record; 100 of the 102 references it cites were found in a registry or an index.
Chemometric analysis in Raman spectroscopy from experimental design to machine learning–based modeling
Abstract
Raman spectroscopy is increasingly being used in biology, forensics, diagnostics, pharmaceutics and food science applications. This growth is triggered not only by improvements in the computational and experimental setups but also by the development of chemometric techniques. Chemometric techniques are the analytical processes used to detect and extract information from subtle differences in Raman spectra obtained from related samples. This information could be used to find out, for example, whether a mixture of bacterial cells contains different species, or whether a mammalian cell is healthy or not. Chemometric techniques include spectral processing (ensuring that the spectra used for the subsequent computational processes are as clean as possible) as well as the statistical analysis of the data required for finding the spectral differences that are most useful for differentiation between, for example, different cell types. For Raman spectra, this analysis process is not yet standardized, and there are many confounding pitfalls. This protocol provides guidance on how to perform a Raman spectral analysis: how to avoid these pitfalls, and strategies to circumvent problematic issues. The protocol is divided into four parts: experimental design, data preprocessing, data learning and model transfer. We exemplify our workflow using three example datasets where the spectra from individual cells were collected in single-cell mode, and one dataset where the data were collected from…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite the wealth of information RS affords, the analysis and interpretation of experimental RS data remains a major challenge (37–39).”
From Hyperspectral unmixing for Raman spectroscopy via physics-constrained autoencoders (2024) · cites this paper as [38]
Citations
Cites
The Elements of Statistical Learning
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7 · Cited by 25,970
Reducing the dimensionality of data with neural networks
Hinton, G. E., & Salakhutdinov, R. R. (2006) · Science · doi:10.1126/science.1127647 · Cited by 20,928
The FAIR Guiding Principles for scientific data management and stewardship
Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J., Appleton, G., Axton, M., Baak, A., Blomberg, N., Boiten, J.-W., da Silva Santos, L. B., Bourne, P. E., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.18 · Cited by 18,423
THE USE OF MULTIPLE MEASUREMENTS IN TAXONOMIC PROBLEMS
FISHER, R. A. (1936) · Annals of Eugenics · doi:10.1111/j.1469-1809.1936.tb02137.x · Cited by 15,227
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
Experimental Design and Data Analysis for Biologists
Quinn, G. P., & Keough, M. J. (2002) · doi:10.1017/cbo9780511806384 · Cited by 10,674
Cohen, J. (1992) · Current Directions in Psychological Science · doi:10.1111/1467-8721.ep10768783 · Cited by 5,870
Effect size, confidence interval and statistical significance: a practical guide for biologists
Nakagawa, S., & Cuthill, I. C. (2007) · Biological Reviews · doi:10.1111/j.1469-185x.2007.00027.x · Cited by 3,835
Partial least squares for discrimination
Barker, M., & Rayens, W. (2003) · Journal of Chemometrics · doi:10.1002/cem.785 · Cited by 2,841
Vertex component analysis: a fast algorithm to unmix hyperspectral data
Nascimento, J. M. P., & Dias, J. M. B. (2005) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2005.844293 · Cited by 2,669 · cited 1×
“Typical approaches include vertex component analysis 75 , N-FINDER 74 , independent component analysis 76 and multivariate curve resolution alternative least squares 11 .”
Method
Research works printed but not linked: 4
- Carrabba, M. M. Wavenumber standards for Raman Spectrometry. in Handbook of Vibrational Spectroscopy Vol 1 (Wiley, 2006).
- Eilers, P. H. & Boelens, H. F. Baseline correction with asymmetric least squares smoothing. Leiden-. Univ. Med. Cent. Rep. 1, 5 (2005).
- Theodoridis, S. and Koutroumbas, K. Pattern Recognition 4th edn (Academic Press, 2008).
- Guyon, I. & Elisseeff, A. An introduction to variable and feature selection. J. Mach. Learn. Res. 3, 1157–1182 (2003).
Cited by
Biomedical SERS – the current state and future trends
Cialla-May, D., Bonifacio, A., Bocklitz, T., Markin, A., Markina, N., Fornasaro, S., Dwivedi, A., Dib, T., Farnesi, E., Liu, C., et al. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00090k · Cited by 287
Self-citationLin, L. L., Alvarez-Puebla, R., Liz-Marzán, L. M., Trau, M., Wang, J., Fabris, L., Wang, X., Liu, G., Xu, S., Han, X. X., et al. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c17502 · Cited by 247
Self-citationDeep Learning for Raman Spectroscopy: A Review
Luo, R., Popp, J., & Bocklitz, T. (2022) · Analytica · doi:10.3390/analytica3030020 · Cited by 244
“…and implementation of the pre-processing (sequence) becomes a heavy burden [30]. normalisation as well as dimension reduction are always needed [2,29]. the computational complexity of the above-mentioned pre-processing sequence is high simply no universal pre-processing technique exists, the…”
Self-citationRecent Progresses in Machine Learning Assisted Raman Spectroscopy
Qi, Y., Hu, D., Jiang, Y., Wu, Z., Zheng, M., Chen, E. X., Liang, Y., Sadi, M. A., Zhang, K., & Chen, Y. P. (2023) · Advanced Optical Materials · doi:10.1002/adom.202203104 · Cited by 250
Machine Learning-Assisted Low-Dimensional Electrocatalysts Design for Hydrogen Evolution Reaction
Li, J., Wu, N., Zhang, J., Wu, H.-H., Pan, K., Wang, Y., Liu, G., Liu, X., Yao, Z., & Zhang, Q. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01192-5 · Cited by 207
Metadata
- Authors
- Guo, S., Popp, J., & Bocklitz, T.
- Affiliations
- Leibniz Institute of Photonic Technology (DE)
- Venue
- Nature Protocols
- Published
- 2021-11-05
- Volume
- 16
- Issue
- 12
- Pages
- 5426-5459
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W3210254907
- Cited by
- 361
- References
- 102
- Citations by year
- 2026: 98 · 2025: 98 · 2024: 78 · 2023: 46 · 2022: 41
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Protocols (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Raman spectroscopy, chemometrics, experimental design, spectral preprocessing, machine learning modeling, model transfer, single-cell Raman spectroscopy, Raman imaging, cell classification
- MeSH terms
- Machine Learning, Chemometrics, Animals, Calibration, Data Interpretation, Statistical, Humans, Reference Standards, Spectrum Analysis, Raman, Models, Statistical, Principal Component Analysis, Mice, Datasets as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemometric analysis in Raman spectroscopy from experimental design to machine learning–based modeling. https://app.cochat.ai/papers/10.1038/s41596-021-00620-3
- The paper
- Guo, S., Popp, J., & Bocklitz, T. (2021). Chemometric analysis in Raman spectroscopy from experimental design to machine learning–based modeling. Nature Protocols. https://doi.org/10.1038/s41596-021-00620-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.