Diagnostic Accuracy of Ultrasound Scanning for Prenatal Microcephaly in the context of Zika Virus Infection: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
To assess the accuracy of ultrasound measurements of fetal biometric parameters for prenatal diagnosis of microcephaly in the context of Zika virus (ZIKV) infection, we searched bibliographic databases for studies published until March 3rd, 2016. We extracted the numbers of true positives, false positives, true negatives, and false negatives and performed a meta-analysis to estimate group sensitivity and specificity. Predictive values for ZIKV-infected pregnancies were extrapolated from those obtained for pregnancies unrelated to ZIKV. Of 111 eligible full texts, nine studies met our inclusion criteria. Pooled estimates from two studies showed that at 3, 4 and 5 standard deviations (SDs) <mean, sensitivities were 84%, 68% and 58% for head circumference (HC); 76%, 58% and 58% for occipitofrontal diameter (OFD); and 94%, 85% and 59% for biparietal diameter (BPD). Specificities at 3, 4 and 5 SDs below the mean were 70%, 91% and 97% for HC; 84%, 97% and 97% for OFD; and 16%, 46% and 80% for BPD. No study including ZIKV-infected pregnant women was identified. OFD and HC were more consistent in specificity and sensitivity at lower thresholds compared to higher thresholds. Therefore, prenatal ultrasound appears more accurate in detecting the absence of microcephaly than its presence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Oliveira Melo, A. S., Malinger, G., Ximenes, R., Szejnfeld, P. O., Alves Sampaio, S., & Bispo de Filippis, A. M. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15831 · Cited by 1,180
Association between Zika virus and microcephaly in French Polynesia, 2013–15: a retrospective study
Cauchemez, S., Besnard, M., Bompard, P., Dub, T., Guillemette-Artur, P., Eyrolle-Guignot, D., Salje, H., Van Kerkhove, M. D., Abadie, V., Garel, C., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00651-6 · Cited by 945
Jones, K. L. (1983) · PubMed · Cited by 842
Jones, C. M., & Athanasiou, T. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.09.040 · Cited by 523
Churches, T. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-1 · Cited by 239
Turok, D., & Horn, J. T. V. (2004) · Handbook of Primary Care Psychology · doi:10.1093/oso/9780195149395.003.0008 · Cited by 233
Benoist, G., Salomon, L. J., Mohlo, M., Suarez, B., Jacquemard, F., & Ville, Y. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.6129 · Cited by 164
A normal second‐trimester ultrasound does not exclude intracranial structural pathology
Malinger, G., Lerman‐Sagie, T., Watemberg, N. M., Rotmensch, S., Lev, D., & Glezerman, M. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2002.00743.x · Cited by 116
Benson, C. B., & Doubilet, P. M. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.157.6.1950881 · Cited by 106
Developmental outcome of isolated fetal microcephaly
Stoler-Poria, S., Lev, D., Schweiger, A., Lerman‐Sagie, T., & Malinger, G. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7556 · Cited by 76
Leibovitz, Z., Daniel‐Spiegel, E., Malinger, G., Haratz, K. K., Tamarkin, M., Gindes, L., Schreiber, L., Ben‐Sira, L., Lev, D., Shapiro, I., et al. (2015) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.15801 · Cited by 76
The accuracy of prenatal ultrasonography in detecting congenital anomalies
Gonçalves, L. F., Jeanty, P., & Piper, J. M. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(94)90411-1 · Cited by 67
Difficulties in the prenatal diagnosis of microcephaly.
Bromley, B., & Benacerraf, B. R. (1995) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1995.14.4.303 · Cited by 60
Sonographic prenatal diagnosis of central nervous system abnormalities
Aubry, M. C., Aubry, J. P., & Dommergues, M. (2003) · Child's Nervous System · doi:10.1007/s00381-003-0768-3 · Cited by 58
Sonographic estimation of fetal head circumference: how accurate are we?
Melamed, N., Yogev, Y., Danon, D., Mashiach, R., Meizner, I., & Ben‐Haroush, A. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7760 · Cited by 54
Fetal head and abdominal circumferences: I. Evaluation of measurement errors
Deter, R. L., Harrist, R. B., Hadlock, F. P., & Carpenter, R. J. (1982) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870100803 · Cited by 47
Improved prediction of gestational age from fetal head measurements
Doubilet, P., & Greenes, R. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.4.797 · Cited by 31
Metadata
- Authors
- Chibueze, E. C., Parsons, A. J. Q., Lopes, K. D. S., Yo, T., Swa, T., Nagata, C., Horita, N., Morisaki, N., Balogun, O. O., Dagvadorj, A., Ota, E., Mori, R., & Oladapo, O. T.
- Venue
- Scientific Reports
- Published
- 2017-05-23
- Volume
- 7
- Issue
- 1
- Pages
- 2310-2310
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2614571502
- Cited by
- 287
- References
- 18
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.