Sonographic prediction of gestational age: accuracy of second- and third-trimester fetal measurements.
The DOI matches its Crossref record.
Abstract
We measured the accuracy of second- and third-trimester sonographic predictors of gestational age against highly reliable gold standard (crown-rump length) in a group of fetuses. Using a prospectively collected computerized data base, we selected 460 fetal sonograms obtained at 14-42 weeks of gestation in which age could be reliably established on the basis of crown-rump length in the first trimester. We used data obtained from these sonograms to compare several predictors of fetal age. The accuracy of all predictors worsened progressively as pregnancy proceeded. In the second trimester, corrected biparietal diameter and head circumference were more accurate predictors of gestational age than were biparietal diameter, femoral length, and abdominal circumference (p less than .05, F test). In the third trimester, the corrected biparietal diameter, head circumference, and femoral length were the best predictors, significantly better than biparietal diameter and abdominal circumference (p less than .05, F test). Prediction of gestational age that relies on a single sonographic measurement should be based on the head circumference or corrected biparietal diameter in the second trimester and on one of these two predictors or the femoral length in the third trimester.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Committee Opinion No. 700: Methods for estimating the due date
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002046 · Cited by 683
Chibueze, E. C., Parsons, A. J. Q., Lopes, K. D. S., Yo, T., Swa, T., Nagata, C., Horita, N., Morisaki, N., Balogun, O. O., Dagvadorj, A., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01991-y · Cited by 287
Committee Opinion No 611: Method for Estimating Due Date
(2014) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000454932.15177.be · Cited by 258
Reddy, U. M., Abuhamad, A. Z., Levine, D., & Saade, G. R. (2014) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.02.028 · Cited by 253
Predicting delivery date by ultrasound and last menstrual period in early gestation
Taipale, P. (2001) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(00)01131-5 · Cited by 216
Metadata
- Authors
- Benson, C. B., & Doubilet, P. M.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1991-12
- Volume
- 157
- Issue
- 6
- Pages
- 1275-1277
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2016016768
- Cited by
- 106
- References
- 0
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sonographic prediction of gestational age: accuracy of second- and third-trimester fetal measurements. https://app.cochat.ai/papers/10.2214/ajr.157.6.1950881
- The paper
- Benson, C. B., & Doubilet, P. M. (1991). Sonographic prediction of gestational age: accuracy of second- and third-trimester fetal measurements. American Journal of Roentgenology. https://doi.org/10.2214/ajr.157.6.1950881
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.