Cited by 69Lymphatic System and DiseasesLymphatic Disorders and TreatmentsParasitic Diseases Research and Treatment

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Demonstration and Analysis of the Suction Effect for Pumping Lymph from Tissue Beds at Subatmospheric Pressure

Open access

Abstract

Many tissues exhibit subatmospheric interstitial pressures under normal physiologic conditions. The mechanisms by which the lymphatic system extracts fluid from these tissues against the overall pressure gradient are unknown. We address this important physiologic issue by combining experimental measurements of contractile function and pressure generation with a previously validated mathematical model. We provide definitive evidence for the existence of ‘suction pressure’ in collecting lymphatic vessels, which manifests as a transient drop in pressure downstream of the inlet valve following contraction. This suction opens the inlet valve and is required for filling in the presence of low upstream pressure. Positive transmural pressure is required for this suction, providing the energy required to reopen the vessel. Alternatively, external vessel tethering can serve the same purpose when the transmural pressure is negative. Suction is transmitted upstream, allowing fluid to be drawn in through initial lymphatics. Because suction plays a major role in fluid entry to the lymphatics and is affected by interstitial pressure, our results introduce the phenomenon as another important factor to consider in the study of lymphoedema and its treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-017-11599-x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Expansion of the collecting LV wall during lymphatic diastole produces a transient negative pressure pulse (suction force) that is transmitted back to the lymphatic capillary network to create the hydrostatic pressure gradient that pulls interstitial fluid into the capillary lumen.

    “Expansion of the collecting LV wall during lymphatic diastole produces a transient negative pressure pulse (relative to the baseline pressure)—a suction force—that (presumably) is transmitted back to the lymphatic capillary network to create the hydrostatic pressure gradient that pulls interstitial fluid into the lumen of the capillary (51).”

    From Transport and Immune Functions of the Lymphatic System. (2025) · cites this paper as [51]

  • Ex vivo studies and numerical modeling show that suction is enhanced and prolonged by the addition of upstream resistance to simulate a capillary network.

    “Although transmission of suction upstream to lymphatic capillary networks has not been demonstrated in vivo, ex vivo studies and numerical modeling show that suction is enhanced and prolonged by the addition of upstream resistance to simulate a capillary network, thus providing support for this principle (51).”

    From Transport and Immune Functions of the Lymphatic System. (2025) · cites this paper as [51]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 46

  1. Guyton, A. C. & Coleman, T. G. Regulation of interstitial fluid volume and pressure. Annals of the New York Academy of Sciences 150, 537–547, https://doi.org/10.1111/j.1749-6632.1968.tb14705.x (1968). · DOI
  2. Clough, G. & Smaje, L. H. Simultaneous measurement of pressure in the interstitium and the terminal lymphatics of the cat mesentery. The Journal of Physiology 283, 457–468 (1978). · DOI
  3. Granger, H. J., Lane, G. A., Barnes, G. E. & Lewis, R. E. Dynamics and control of transmicrovascular fluid exchange. Edema 8, 189–224 (1984).
  4. Hogan, R. D. The initial lymphatics and interstitial fluid pressure. In “Tissue Fluid Pressure and Composition” (A. R. Hargens, ed.). Williams and Wilkins, Baltimore., 155–163 (1981).
  5. Moriondo, A., Mukenge, S. & Negrini, D. Transmural pressure in rat initial subpleural lymphatics during spontaneous or mechanical ventilation. American Journal of Physiology–Heart and Circulatory Physiology 289, H263–H269, https://doi.org/10.1152/ajpheart.00060.2005 (2005). · DOI
  6. Zweifach, B. W. & Prather, J. W. Micromanipulation of pressure in terminal lymphatics in the mesentery. American Journal of Physiology 228, 1326–1335 (1975). · DOI
  7. Mislin, H. Structural and functional relations of the mesenteric lymph vessels. Progress in Lymphology. Proceedings of the International Symposium on Lymphology, 87–96 (1966).
  8. Schmid-Schönbein, G. W. Microlymphatics and lymph flow. Physiological Reviews 70, 987–1028 (1990). · DOI
  9. Zawieja, D. C. Contractile physiology of lymphatics. Lymphatic Research and Biology 7, 87–96, https://doi.org/10.1089/lrb.2009.0007 (2009). · DOI
  10. Gashev, A. A. & Zawieja, D. C. Physiology of human lymphatic contractility: a historical perspective. Lymphology 34, 124–134 (2001).
  11. Guyton, A. C., Granger, H. J. & Taylor, A. E. Interstitial fluid pressure. Physiological Reviews 51, 527–563 (1971). · DOI
  12. Hogan, R. D. & Unthank, J. L. The initial lymphatics as sensors of interstitial fluid volume. Microvascular Research 31, 317–324, https://doi.org/10.1016/0026-2862(86)90020-8 (1986). · DOI · Paper page
  13. Negrini, D., Moriondo, A. & Mukenge, S. Transmural pressure during cardiogenic oscillations in rodent diaphragmatic lymphatic vessels. Lymphatic Research and Biology 2, 69–81, https://doi.org/10.1089/lrb.2004.2.69 (2004). · DOI
  14. Gashev, A., Orlov, R. & Zawieja, D. [Contractions of the lymphangion under low filling conditions and the absence of stretching stimuli. The possibility of the sucking effect]. Ross Fiziol Zh Im I M Sechenova 87, 97–109 (2001).
  15. Trzewik, J., Mallipattu, S. K., Artmann, G. M., Delano, F. A. & Schmid-Schönbein, G. W. Evidence for a second valve system in lymphatics: endothelial microvalves. The FASEB Journal 15, 1711–1717 (2001). · DOI
  16. Parsons, R. J. & McMaster, P. D. The effect of the pulse upon the formation and flow of lymph. The Journal of Experimental Medicine 68, 353–376 (1938). · DOI
  17. McMaster, P. D. The relative pressures within cutaneous lymphatic capillaries and the tissues. The Journal of Experimental Medicine 86, 293–308 (1947). · DOI
  18. McMaster, P. D. The lymphatics and lymph flow in the edematous skin of human beings with cardiac and renal disease. The Journal of Experimental Medicine 65, 373–392 (1937). · DOI
  19. Benoit, J. N., Zawieja, D. C., Goodman, A. H. & Granger, H. J. Characterization of intact mesenteric lymphatic pump and its responsiveness to acute edemagenic stress. American Journal of Physiology–Heart and Circulatory Physiology 257, H2059–H2069 (1989). · DOI
  20. Gashev, A. A., Davis, M. J., Delp, M. D. & Zawieja, D. C. Regional variations of contractile activity in isolated rat lymphatics. Microcirculation 11, 477–492, https://doi.org/10.1080/10739680490476033 (2004). · DOI
  21. Davis, M. J. et al. Intrinsic increase in lymphangion muscle contractility in response to elevated afterload. American Journal of Physiology–Heart and Circulatory Physiology 303, H795–H808, https://doi.org/10.1152/ajpheart.01097.2011 (2012). · DOI · Paper page
  22. Davis, M. J., Rahbar, E., Gashev, A. A., Zawieja, D. C. & Moore, J. E. Determinants of valve gating in collecting lymphatic vessels from rat mesentery. American Journal of Physiology–Heart and Circulatory Physiology 301, H48–H60, https://doi.org/10.1152/ajpheart.00133.2011 (2011). · DOI
  23. Sloas, D. et al. Estimation of the pressure drop required for lymph flow through initial lymphatic networks. Lymphatic Research and Biology 14(2), 62–69, https://doi.org/10.1089/lrb.2015.0039 (2016). · DOI
  24. Bates, D. O., Levick, J. R. & Mortimer, P. S. Starling pressures in the human arm and their alteration in postmastectomy oedema. The Journal of Physiology 477, 355–363 (1994). · DOI
  25. Grimaldi, A. et al. Functional arrangement of rat diaphragmatic initial lymphatic network. American Journal of Physiology–Heart and Circulatory Physiology 291, H876–H885 (2006). · DOI
  26. Zamir, M., Moore, J. E. Jr, Fujioka, H. & Gaver, D. P. III Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28–30, 2008 Pasadena, California. Annals of Biomedical Engineering 38, 1204–1215, https://doi.org/10.1007/s10439-010-9902-z (2010). · DOI
  27. Bridenbaugh, E. A. et al. An immunological fingerprint differentiates muscular lymphatics from arteries and veins. Lymphatic Research and Biology 11, 155–171, https://doi.org/10.1089/lrb.2013.0023 (2013). · DOI
  28. Kunert, C., Baish, J. W., Liao, S., Padera, T. P. & Munn, L. L. Mechanobiological oscillators control lymph flow. Proceedings of the National Academy of Sciences 112, 10938–10943, https://doi.org/10.1073/pnas.1508330112 (2015). · DOI
  29. Jamalian, S., Bertram, C. D., Richardson, W. J. & Moore, J. E. Parameter sensitivity analysis of a lumped-parameter model of a chain of lymphangions in series. American Journal of Physiology–Heart and Circulatory Physiology 305(12), H1709–H1717, https://doi.org/10.1152/ajpheart.00403.2013 (2013). · DOI
  30. Jamalian, S., Davis, M., Zawieja, D. & Moore, J. E. Network scale modeling of lymph transport and its effective pumping. Parameters. 11(2), e0148384, https://doi.org/10.1371/journal.pone.0148384 (2016). · DOI
  31. Bertram, C. D., Macaskill, C. & Moore, J. E. Jr. Simulation of a chain of collapsible contracting lymphangions with progressive valve closure. Journal of Biomechanical Engineering 133(1), 011008, https://doi.org/10.1115/1.4002799 (2011). · DOI
  32. Preston, N. J., Seers, K. & Mortimer, P. S. Physical therapies for reducing and controlling lymphoedema of the limbs. Cochrane Database of Systematic Reviews 4, CD003141, https://doi.org/10.1002/14651858.CD003141.pub2 (2004). · DOI
  33. Rockson, S. G. Lymphedema. The American Journal of Medicine 110, 288–295, https://doi.org/10.1016/S0002-9343(00)00727-0 (2001). · DOI
  34. Wu, T. F., Carati, C. J., MacNaughton, W. K. & von der Weid, P.-Y. Contractile activity of lymphatic vessels is altered in the TNBS model of guinea pig ileitis. American Journal of Physiology–Gastrointestinal and Liver Physiology 291, G566–G574, https://doi.org/10.1152/ajpgi.00058.2006 (2006). · DOI
  35. Cromer, W. et al. Colonic insult impairs lymph flow, increases cellular content of the lymph, alters local lymphatic micro-environment and leads to sustained inflammation in the rat ileum. Inflammatory Bowel Diseases 21, 1553–1563, https://doi.org/10.1097/MIB.0000000000000402 (2015). · DOI
  36. Zawieja, S. D. et al. Impairments in the intrinsic contractility of mesenteric collecting lymphatics in a rat model of metabolic syndrome. American Journal of Physiology–Heart and Circulatory Physiology 302, H643–H653, https://doi.org/10.1152/ajpheart.00606.2011 (2012). · DOI
  37. Blum, K. S. et al. Chronic high-fat diet impairs collecting lymphatic vessel function in mice. PLoS One 9(4), e94713, https://doi.org/10.1371/journal.pone.0094713 (2014). · DOI
  38. Akl, T. J., Nagai, T., Coté, G. L. & Gashev, A. A. Mesenteric lymph flow in adult and aged rats. American Journal of Physiology–Heart and Circulatory Physiology 301(5), H1828–H1840, https://doi.org/10.1152/ajpheart.00538.2011 (2011). · DOI
  39. García-Cruz, D. et al. Cantu syndrome and lymphoedema. Clinical Dysmorphology 20(1), 32–37, https://doi.org/10.1097/MCD.0b013e32833d015c (2011). · DOI
  40. Davis, M. J., Zawieja, D. C. & Gashev, A. A. Automated measurement of diameter and contraction waves of cannulated lymphatic microvessels. Lymphatic Research and Biology 4, 3–10, https://doi.org/10.1089/lrb.2006.4.3 (2006). · DOI
  41. Davis, M. J. & Davidson, J. Force-velocity relationship of myogenically active arterioles. American Journal of Physiology–Heart and Circulatory Physiology 282, H165–H174 (2002). · DOI
  42. Bertram, C. D., Macaskill, C. & Moore, J. E. Simulation of a chain of collapsible contracting lymphangions with progressive valve closure. ASME Journal of Biomechanical Engineering 133(1), 011008-1–011008-10, https://doi.org/10.1115/1.4002799 (2011). · DOI
  43. Akl, T. J., Nepiyushchikh, Z. V., Gashev, A. A., Zawieja, D. C. & Coté, G. L. Measuring contraction propagation and localizing pacemaker cells using high speed video microscopy. Journal of Biomedical Optics 16(2), 026016-1–026016-9, doi:https://doi.org/10.1117/1.3544512 (2011). · DOI
  44. Margaris, K. N., Nepiyushchikh, Z., Zawieja, D. C., Moore, J. J. & Black, R. A. Microparticle image velocimetry approach to flow measurements in isolated contracting lymphatic vessels. Journal of Biomedical Optics 21(2), 025002-1–025002-11, https://doi.org/10.1117/1.JBO.21.2.025002 (2016). · DOI
  45. Bertram, C. D., Macaskill, C., Davis, M. J. & Moore, J. E. Jr. Development of a model of a multi-lymphangion lymphatic vessel incorporating realistic and measured parameter values. Biomechanics and Modeling in Mechanobiology 13(2), 401–416, https://doi.org/10.1007/s10237-013-0505-0 (2014). · DOI
  46. Bertram, C. D., Macaskill, C., Davis, M. J. & Moore, J. E. Consequences of intravascular lymphatic valve properties: a study of contraction timing in a multi-lymphangion model. American Journal of Physiology–Heart and Circulatory Physiology 310, H847–H860, https://doi.org/10.1152/ajpheart.00669.2015 (2016). · DOI

Cited by

Sorted by citations

Metadata

Authors
Jamalian, S., Jafarnejad, M., Zawieja, S. D., Bertram, C. D., Gashev, A. A., Zawieja, D. C., Davis, M. J., & Moore, J. E.
Affiliations
  • Imperial College London (GB)
  • University of Missouri (US)
  • The University of Sydney (AU)
  • Texas A&M University (US)
Corresponding author
  • Davis, Michael J.
  • Moore, James E.
Venue
Scientific Reports
Published
2017-09-21
Volume
7
Issue
1
Pages
12080-12080
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2755292037
Cited by
69
References
1
Citations by year
2026: 5 · 2025: 11 · 2024: 9 · 2023: 10 · 2022: 6 · 2021: 8 · 2020: 5 · 2019: 8 · 2018: 7
FWCI
2.41
Type
journal article
Language
en
Open access
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • Royal Academy of Engineering
  • Royal Society
  • National Institutes of Health
  • National Heart, Lung, and Blood Institute (R01HL070308, R01HL120867, R01HL122578, U01HL123420, R01HL125608, R01HL096552, R01HL094269)
Topics
  • Health Sciences › Medicine › Oncology › Lymphatic System and Diseases
  • Health Sciences › Medicine › Surgery › Lymphatic Disorders and Treatments
  • Health Sciences › Medicine › Infectious Diseases › Parasitic Diseases Research and Treatment
Keywords
lymphatic pumping, suction pressure, sub-atmospheric pressure, lymphatic vessels, transmural pressure, interstitial fluid pressure, lymphedema
MeSH terms
Animals, Atmospheric Pressure, Lymph, Lymphatic System, Lymphedema, Male, Suction, Rats, Sprague-Dawley, Lymphatic Vessels

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review