Sub-parts-per-trillion level sensitivity in trace gas detection by cantilever-enhanced photo-acoustic spectroscopy
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
An exceptional property of photo-acoustic spectroscopy is the zero-background in wavelength modulation configuration while the signal varies linearly as a function of absorbed laser power. Here, we make use of this property by combining a highly sensitive cantilever-enhanced photo-acoustic detector, a particularly stable high-power narrow-linewidth mid-infrared continuous-wave optical parametric oscillator, and a strong absorption cross-section of hydrogen fluoride to demonstrate the ability of cantilever-enhanced photo-acoustic spectroscopy to reach sub-parts-per-trillion level sensitivity in trace gas detection. The high stability of the experimental setup allows long averaging times. A noise equivalent concentration of 650 parts-per-quadrillion is reached in 32 minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
The HITRAN2012 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Babikov, Y., Barbe, A., Chris Benner, D., Bernath, P. F., Birk, M., Bizzocchi, L., Boudon, V., Brown, L. R., et al. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2013.07.002 · Cited by 3,255
Werle, P., M�cke, R., & Slemr, F. (1993) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00425997 · Cited by 947
Extended pseudo-Voigt function for approximating the Voigt profile
Ida, T., Ando, M., & Toraya, H. (2000) · Journal of Applied Crystallography · doi:10.1107/s0021889800010219 · Cited by 306
Renfew, M. M. (1991) · Journal of Chemical Education · doi:10.1021/ed068pa232.3 · Cited by 246
Molecular Gas Sensing Below Parts Per Trillion: Radiocarbon-Dioxide Optical Detection
Galli, I., Bartalini, S., Borri, S., Cancio, P., Mazzotti, D., De Natale, P., & Giusfredi, G. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.270802 · Cited by 198
Spectroscopic detection of radiocarbon dioxide at parts-per-quadrillion sensitivity
Galli, I., Bartalini, S., Ballerini, R., Barucci, M., Cancio, P., Pas, M. D., Giusfredi, G., Mazzotti, D., Akikusa, N., & Natale, P. D. (2016) · Optica · doi:10.1364/optica.3.000385 · Cited by 167
Spagnolo, V., Patimisco, P., Borri, S., Scamarcio, G., Bernacki, B. E., & Kriesel, J. (2012) · Optics Letters · doi:10.1364/ol.37.004461 · Cited by 164
Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy
Koskinen, V., Fonsen, J., Kauppinen, J. K., & Kauppinen, I. (2006) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2006.05.018 · Cited by 78
Cantilever enhanced photoacoustic detection of carbon dioxide using a tunable diode laser source
Koskinen, V., Fonsen, J., Roth, K., & Kauppinen, J. K. (2007) · Applied Physics B · doi:10.1007/s00340-006-2560-z · Cited by 78
Walna, B., Kurzyca, I., Bednorz, E., & Kolendowicz, L. (2012) · Environmental Monitoring and Assessment · doi:10.1007/s10661-012-2962-9 · Cited by 70
Improved Tuning Fork for Terahertz Quartz-Enhanced Photoacoustic Spectroscopy
Sampaolo, A., Patimisco, P., Giglio, M., Vitiello, M. S., Beere, H. E., Ritchie, D. A., Scamarcio, G., Tittel, F. K., & Spagnolo, V. (2016) · Sensors · doi:10.3390/s16040439 · Cited by 68
Peltola, J., Hieta, T., & Vainio, M. (2015) · Optics Letters · doi:10.1364/ol.40.002933 · Cited by 64
Self-citationPeltola, J., Vainio, M., Hieta, T., Uotila, J., Sinisalo, S., Metsälä, M., Siltanen, M., & Halonen, L. (2013) · Optics Express · doi:10.1364/oe.21.010240 · Cited by 63
Self-citationHigh finesse optical cavity coupled with a quartz-enhanced photoacoustic spectroscopic sensor
Patimisco, P., Borri, S., Galli, I., Mazzotti, D., Giusfredi, G., Akikusa, N., Yamanishi, M., Scamarcio, G., Natale, P. D., & Spagnolo, V. (2014) · The Analyst · doi:10.1039/c4an01158a · Cited by 62
Wu, H., Dong, L., Zheng, H., Yu, Y., Ma, W., Zhang, L., Yin, W., Xiao, L., Jia, S., & Tittel, F. K. (2017) · Nature Communications · doi:10.1038/ncomms15331
Xiong, L., Bai, W., Chen, F., Zhao, X., Yu, F., & Diebold, G. J. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1706040114
Cited by
Qiao, S., He, Y., Sun, H., Patimisco, P., Sampaolo, A., Spagnolo, V., & Ma, Y. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01459-5 · Cited by 325
Towards Integrated Mid-Infrared Gas Sensors
Popa, D., & Udrea, F. (2019) · Sensors · doi:10.3390/s19092076 · Cited by 311
Laser sensors for energy systems and process industries: Perspectives and directions
Farooq, A., Alquaity, A. B. S., Raza, M., Nasir, E. F., Yao, S., & Ren, W. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2022.100997 · Cited by 164
Biosensors Based on Mechanical and Electrical Detection Techniques
Chalklen, T., Jing, Q., & Kar-Narayan, S. (2020) · Sensors · doi:10.3390/s20195605 · Cited by 133
Metadata
- Authors
- Tomberg, T., Vainio, M., Hieta, T., & Halonen, L.
- Venue
- Scientific Reports
- Published
- 2018-01-30
- Volume
- 8
- Issue
- 1
- Pages
- 1848-1848
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2793298712
- Cited by
- 171
- References
- 17
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.