CoChat

Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PET

Open access
Ferrero, Veronica, Fiorina, Elisa, Morrocchi, Matteo, Pennazio, Francesco, Baroni, Guido, Battistoni, Giuseppe, Belcari, Nicola, Camarlinghi, Niccolo’, Ciocca, Mario, Del Guerra, Alberto, Donetti, Marco, Giordanengo, Simona, Giraudo, Giuseppe, Patera, Vincenzo, Peroni, Cristiana, Rivetti, Angelo, Rolo, Manuel Dionisio da Rocha, Rossi, Sandro, Rosso, Valeria, Sportelli, Giancarlo, Tampellini, Sara, Valvo, Francesca, Wheadon, Richard, Cerello, Piergiorgio, Bisogni, Maria Giuseppina · 2018 · Scientific Reports
Cited by 197

The DOI matches its Crossref record.

Abstract

Particle therapy exploits the energy deposition pattern of hadron beams. The narrow Bragg Peak at the end of range is a major advantage but range uncertainties can cause severe damage and require online verification to maximise the effectiveness in clinics. In-beam Positron Emission Tomography (PET) is a non-invasive, promising in-vivo technique, which consists in the measurement of the β+ activity induced by beam-tissue interactions during treatment, and presents the highest correlation of the measured activity distribution with the deposited dose, since it is not much influenced by biological washout. Here we report the first clinical results obtained with a state-of-the-art in-beam PET scanner, with on-the-fly reconstruction of the activity distribution during irradiation. An automated time-resolved quantitative analysis was tested on a lacrimal gland carcinoma case, monitored during two consecutive treatment sessions. The 3D activity map was reconstructed every 10 s, with an average delay between beam delivery and image availability of about 6 s. The correlation coefficient of 3D activity maps for the two sessions (above 0.9 after 120 s) and the range agreement (within 1 mm) prove the suitability of in-beam PET for online range verification during treatment, a crucial step towards adaptive strategies in particle therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-22325-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Ferrero, V., Fiorina, E., Morrocchi, M., Pennazio, F., Baroni, G., Battistoni, G., Belcari, N., Camarlinghi, N., Ciocca, M., Del Guerra, A., Donetti, M., Giordanengo, S., Giraudo, G., Patera, V., Peroni, C., Rivetti, A., Rolo, M. D. D. R., Rossi, S., Rosso, V., Sportelli, G., Tampellini, S., Valvo, F., Wheadon, R., Cerello, P., & Bisogni, M. G.
Venue
Scientific Reports
Published
2018-03-06
Volume
8
Issue
1
Pages
4100-4100
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2795013574
Cited by
197
References
0
FWCI
21.31
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PET. https://app.cochat.ai/papers/10.1038/s41598-018-22325-6
The paper
Ferrero, V., Fiorina, E., Morrocchi, M., Pennazio, F., Baroni, G., Battistoni, G., Belcari, N., Camarlinghi, N., Ciocca, M., Del Guerra, A., Donetti, M., Giordanengo, S., Giraudo, G., Patera, V., Peroni, C., Rivetti, A., Rolo, M. D. D. R., Rossi, S., Rosso, V., . . . Bisogni, M. G. (2018). Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PET. Scientific Reports. https://doi.org/10.1038/s41598-018-22325-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.