The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Roadmap toward the 10 ps time-of-flight PET challenge
Open accessAbstract
Since the seventies, positron emission tomography (PET) has become an invaluable medical molecular imaging modality with an unprecedented sensitivity at the picomolar level, especially for cancer diagnosis and the monitoring of its response to therapy. More recently, its combination with x-ray computed tomography (CT) or magnetic resonance (MR) has added high precision anatomic information in fused PET/CT and PET/MR images, thus compensating for the modest intrinsic spatial resolution of PET. Nevertheless, a number of medical challenges call for further improvements in PET sensitivity. These concern in particular new treatment opportunities in the context personalized (also called precision) medicine, such as the need to dynamically track a small number of cells in cancer immunotherapy or stem cells for tissue repair procedures. A better signal-to-noise ratio (SNR) in the image would allow detecting smaller size tumours together with a better staging of the patients, thus increasing the chances of putting cancer in complete remission. Moreover, there is an increasing demand for reducing the radioactive doses injected to the patients without impairing image quality. There are three ways to improve PET scanner sensitivity: improving detector efficiency, increasing geometrical acceptance of the imaging device and pushing the timing performance of the detectors. Currently, some pre-localization of the electron-positron annihilation along a line-of-response (LOR) given by the detection of a pair of annihilation photons is provided by the detection of the time difference between the two photons, also known as the time-of-flight (TOF) difference of the photons, whose accuracy is given by the coincidence time resolution (CTR). A CTR of about 10 picoseconds FWHM will ultimately allow to obtain a direct 3D volume representation of the activity distribution of a positron emitting radiopharmaceutical, at the millimetre level, thus introducing a quantum leap in PET imaging and quantification and fostering more frequent use of 11 C radiopharmaceuticals. The present roadmap article toward the advent of 10 ps TOF-PET addresses the status and current/future challenges along the development of TOF-PET with the objective to reach this mythic 10 ps frontier that will open the door to real-time volume imaging virtually without tomographic inversion. The medical impact and prospects to achieve this technological revolution from the detection and image reconstruction point-of-views, together with a few perspectives beyond the TOF-PET application are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cramming More Components Onto Integrated Circuits
Moore, G. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.658762 · Cited by 5,926
Properties and potential optoelectronic applications of lead halide perovskite nanocrystals
Kovalenko, M. V., Protesescu, L., & Bodnarchuk, M. I. (2017) · Science · doi:10.1126/science.aam7093 · Cited by 2,652
Linewidth dependence of radiative exciton lifetimes in quantum wells
Feldmann, J., Peter, G., Göbel, E. O., Dawson, P., Moore, K., Foxon, C., & Elliott, R. J. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.2337 · Cited by 1,097
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226498 · Cited by 722
Timepix3: a 65K channel hybrid pixel readout chip with simultaneous ToA/ToT and sparse readout
Poikela, T., Plosila, J., Westerlund, T., Campbell, M., Gaspari, M. D., Llopart, X., Gromov, V, Kluit, R., Beuzekom, M. V., Zappon, F., et al. (2014) · Journal of Instrumentation · doi:10.1088/1748-0221/9/05/c05013 · Cited by 559
Cryo-CMOS Circuits and Systems for Quantum Computing Applications
Patra, B., Incandela, R. M., van Dijk, J. P. G., Homulle, H. A. R., Song, L., Shahmohammadi, M., Staszewski, R. B., Vladimirescu, A., Babaie, M., Sebastiano, F., et al. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2737549 · Cited by 551
Self-citationContinuous-wave biexciton lasing at room temperature using solution-processed quantum wells
Grim, J. Q., Christodoulou, S., Di Stasio, F., Krahne, R., Cingolani, R., Manna, L., & Moreels, I. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.213 · Cited by 532
Performance Characteristics of the Digital Biograph Vision PET/CT System
van Sluis, J., de Jong, J., Schaar, J., Noordzij, W., van Snick, P., Dierckx, R., Borra, R., Willemsen, A., & Boellaard, R. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215418 · Cited by 484
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Self-citation
Cited by
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Update on latest advances in time-of-flight PET
Surti, S., & Karp, J. S. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.031 · Cited by 96
Self-citation
Metadata
- Authors
- Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., Varela, J., de La Taille, C., Rivetti, A., Breton, D., Pratte, J.-F., Nuyts, J., Surti, S., Vandenberghe, S., Marsden, P., Parodi, K., Benlloch, J. M., & Benoit, M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-10-20
- Volume
- 65
- Issue
- 21
- Pages
- 21RM01
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3027275779
- Cited by
- 258
- References
- 81
- FWCI
- 15.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Roadmap toward the 10 ps time-of-flight PET challenge. https://app.cochat.ai/papers/10.1088/1361-6560/ab9500
- The paper
- Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., Varela, J., de La Taille, C., Rivetti, A., Breton, D., Pratte, J.-F., Nuyts, J., Surti, S., Vandenberghe, S., Marsden, P., . . . Benoit, M. (2020). Roadmap toward the 10 ps time-of-flight PET challenge. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ab9500
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.