Radar-Based Heart Sound Detection
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
This paper introduces heart sound detection by radar systems, which enables touch-free and continuous monitoring of heart sounds. The proposed measurement principle entails two enhancements in modern vital sign monitoring. First, common touch-based auscultation with a phonocardiograph can be simplified by using biomedical radar systems. Second, detecting heart sounds offers a further feasibility in radar-based heartbeat monitoring. To analyse the performance of the proposed measurement principle, 9930 seconds of eleven persons-under-tests’ vital signs were acquired and stored in a database using multiple, synchronised sensors: a continuous wave radar system, a phonocardiograph (PCG), an electrocardiograph (ECG), and a temperature-based respiration sensor. A hidden semi-Markov model is utilised to detect the heart sounds in the phonocardiograph and radar data and additionally, an advanced template matching (ATM) algorithm is used for state-of-the-art radar-based heartbeat detection. The feasibility of the proposed measurement principle is shown by a morphology analysis between the data acquired by radar and PCG for the dominant heart sounds S1 and S2: The correlation is 82.97 ± 11.15% for 5274 used occurrences of S1 and 80.72 ± 12.16% for 5277 used occurrences of S2. The performance of the proposed detection method is evaluated by comparing the F-scores for radar and PCG-based heart sound detection with ECG as reference: Achieving an F 1 value of 92.22 ± 2.07%, the radar system approximates the score of 94.15 ± 1.61% for the PCG. The accuracy regarding the detection timing of heartbeat occurrences is analysed by means of the root-mean-square error: In comparison to the ATM algorithm (144.9 ms) and the PCG-based variant (59.4 ms), the proposed method has the lowest error value (44.2 ms). Based on these results, utilising the detected heart sounds considerably improves radar-based heartbeat monitoring, while the achieved performance is also competitive to phonocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Evaluation: from precision, recall and F-measure to ROC, informedness, markedness and correlation
Powers, D. M. W. (2020) · arXiv · doi:10.48550/arxiv.2010.16061 · Cited by 5,440
Journal of The American College of Cardiology
(2015) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2015.03.023 · Cited by 2,584
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Evidence-Based Eye Care · doi:10.1097/00132578-200307000-00027 · Cited by 1,793
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Naghavi, M., Falk, E., Hecht, H. S., Jamieson, M. J., Kaul, S., Berman, D., Fayad, Z., Budoff, M. J., Rumberger, J., Naqvi, T. Z., et al. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.03.002 · Cited by 635
Cited by
Contactless Electrocardiogram Monitoring With Millimeter Wave Radar
Chen, J., Zhang, D., Wu, Z., Zhou, F., Sun, Q., & Chen, Y. (2024) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2022.3214721 · Cited by 210
“However, early research in this area focused on monitoring heart rate [8], heart period [9] or even more specific vibration signals from micro-cardiac events [10] rather than direct ECG signals.”
BackgroundRadar-Based Monitoring of Vital Signs: A Tutorial Overview
Paterniani, G., Sgreccia, D., Davoli, A., Guerzoni, G., Di Viesti, P., Valenti, A. C., Vitolo, M., Vitetta, G. M., & Boriani, G. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3244362 · Cited by 201
“The classification of normal or abnormal heart sounds has been investigated in [129].”
BackgroundContactless seismocardiography via deep learning radars
Ha, U., Assana, S., & Adib, F. (2020) · Proceedings of the 26th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3372224.3419982 · Cited by 197
“It is also worth noting that other state-of-the-art work [61] has focused on recovering portions of the PCG waveform (specifically, those corresponding to two of the micro-cardiac events) and demonstrated correlations of 0.”
BackgroundMethodInfluentialMoVi-Fi: motion-robust vital signs waveform recovery via deep interpreted RF sensing
Chen, Z., Zheng, T., Cai, C., & Luo, J. (2021) · Proceedings of the 27th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3447993.3483251 · Cited by 192
“Therefore, instead of recovering SCG-related waveforms [17, 39, 49], we adopt BVP that is equally useful to clinical studies as SCG, as they are both strongly correlated with electrocardiogram (ECG) [38].”
Method
Metadata
- Authors
- Will, C., Shi, K., Schellenberger, S., Steigleder, T., Michler, F., Fuchs, J., Weigel, R., Ostgathe, C., & Koelpin, A.
- Venue
- Scientific Reports
- Published
- 2018-07-26
- Volume
- 8
- Issue
- 1
- Pages
- 11551-11551
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2884613329
- Cited by
- 184
- References
- 45
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.