Simpler, Faster, and Sensitive Zika Virus Assay Using Smartphone Detection of Loop-mediated Isothermal Amplification on Paper Microfluidic Chips
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The recent Zika virus (ZIKV) outbreak has prompted the need for field-ready diagnostics that are rapid, easy-to-use, handheld, and disposable while providing extreme sensitivity and specificity. To meet this demand, we developed a wax-printed paper microfluidic chip utilizing reverse transcription loop-mediated isothermal amplification (RT-LAMP). The developed simple and sensitive ZIKV assay was demonstrated using undiluted tap water, human urine, and diluted (10%) human blood plasma. Paper type, pore size, and channel dimension of various paper microfluidic chips were investigated and optimized to ensure proper filtration of direct-use biological samples (tap water, urine, and plasma) during capillary action-driven flow. Once ZIKV RNA has flowed and reached to a detection area of the paper microfluidic chip, it was excised for the addition of an RT-LAMP mixture with a pH indicator, then placed on a hot plate at 68 °C. Visible color changes from successful amplification were observed in 15 minutes and quantified by smartphone imaging. The limit of detection was as low as 1 copy/μL. The developed platform can also be used for identifying other flaviviruses, such as Chikungunya virus (CHIKV) and Dengue virus (DENV), and potentially other quickly transmitted virus pathogens, towards field-based diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PCR inhibitors - occurrence, properties and removal
Schrader, C., Schielke, A., Ellerbroek, L., & Johne, R. (2012) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2012.05384.x · Cited by 2,118
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Purification and Characterization of PCR-Inhibitory Components in Blood Cells
Al-Soud, W. A., & Rådström, P. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.2.485-493.2001 · Cited by 944
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Large-scale sequencing of human influenza reveals the dynamic nature of viral genome evolution
Ghedin, E., Sengamalay, N. A., Shumway, M., Zaborsky, J., Feldblyum, T., Subbu, V., Spiro, D. J., Sitz, J., Koo, H., Bolotov, P., et al. (2005) · Nature · doi:10.1038/nature04239 · Cited by 466
Yamada, K., Shibata, H., Suzuki, K., & Citterio, D. (2017) · Lab on a Chip · doi:10.1039/c6lc01577h · Cited by 437
Dengue, Zika and Chikungunya: Emerging Arboviruses in the New World
Patterson, J., Sammon, M., & Garg, M. (2016) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2016.9.30904 · Cited by 331
Instrument-Free Point-of-Care Molecular Detection of Zika Virus
Song, J., Mauk, M. G., Hackett, B. A., Cherry, S., Bau, H. H., & Liu, C. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01632 · Cited by 310
A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses
Priye, A., Bird, S. W., Light, Y. K., Ball, C. S., Negrete, O. A., & Meagher, R. J. (2017) · Scientific Reports · doi:10.1038/srep44778 · Cited by 300
Heukelbach, J., Alencar, C. H., Kelvin, A. A., De Oliveira, W. K., & Pamplona de Góes Cavalcanti, L. (2016) · The Journal of Infection in Developing Countries · doi:10.3855/jidc.8217 · Cited by 239
WU, D. Y., UGOZZOLI, L., PAL, B. K., QIAN, J., & WALLACE, R. B. (1991) · DNA and Cell Biology · doi:10.1089/dna.1991.10.233 · Cited by 192
Overcoming Inhibition in Real-Time Diagnostic PCR
Hedman, J., & Rådström, P. (2013) · Methods in Molecular Biology · doi:10.1007/978-1-60327-353-4_2 · Cited by 164
Ganguli, A., Ornob, A., Yu, H., Damhorst, G. L., Chen, W., Sun, F., Bhuiya, A. M., Cunningham, B. T., & Bashir, R. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0209-9 · Cited by 157
Oduyebo, T., Polen, K. D., Walke, H. T., Reagan-Steiner, S., Lathrop, E., Rabe, I. B., Kuhnert-Tallman, W., Martin, S. W., Walker, A. T., Gregory, C. J., et al. (2017) · MMWR Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm6629e1 · Cited by 149
Structure, stability and behaviour of nucleic acids in ionic liquids
Tateishi‐Karimata, H., & Sugimoto, N. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku499 · Cited by 139
Calvert, A. E., Biggerstaff, B. J., Tanner, N. A., Lauterbach, M., & Lanciotti, R. S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0185340 · Cited by 115
Cunha, M. S., Espósito, D. L. A., Rocco, I. M., Maeda, A. Y., Vasami, F. G. S., Nogueira, J. S., de Souza, R. P., Suzuki, A., Addas‐Carvalho, M., Barjas‐Castro, M. L., et al. (2016) · Genome Announcements · doi:10.1128/genomea.00032-16 · Cited by 114
Tian, B., Qiu, Z., Ma, J., de la Torre, T. Z. G., Johansson, C., Svedlindh, P., & Strömberg, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.085 · Cited by 109
Simple and Highly Sensitive Molecular Diagnosis of Zika Virus by Lateral Flow Assays
Lee, J. H., Shin, Y. M., Chung, S. H., Hwang, K. S., Yoon, D. S., & Lee, J. H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03460 · Cited by 95
Kurosaki, Y., Martins, D. B. G., Kimura, M., Catena, A. D. S., Borba, M. A. C. S. M., Mattos, S. D. S., Abe, H., Yoshikawa, R., Filho, J. L. D. L., & Yasuda, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-13836-9 · Cited by 68
Future developments in biosensors for field-ready Zika virus diagnostics
Nicolini, A. M., McCracken, K. E., & Yoon, J. (2017) · Journal of Biological Engineering · doi:10.1186/s13036-016-0046-z · Cited by 59
Self-citationEngineering Paper-Based Sensors for Zika Virus
Meagher, R. J., Negrete, O. A., & Rompay, K. K. A. V. (2016) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2016.05.009 · Cited by 38
Cited by
Yang, S.-M., Lv, S., Zhang, W., & Cui, Y. (2022) · Sensors · doi:10.3390/s22041620 · Cited by 299
Point of care testing for infectious diseases
Chen, H., Liu, K., Li, Z., & Wang, P. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.03.008 · Cited by 270
Paul, R., Ostermann, E., & Wei, Q. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112592 · Cited by 211
“For colorimetric detection of the LAMP assay, pH-sensitive dyes (Kaarj et al., 2018), metal ion indicators (Port et al., 2014; Seok et al., 2017), or functionalized gold nanoparticles (Choi et al., 2016) have been reported as color indicators in the literature.”
BackgroundMethodInfluentialIsothermal amplifications – a comprehensive review on current methods
Glökler, J., Lim, T. S., Ida, J., & Frohme, M. (2021) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.1080/10409238.2021.1937927 · Cited by 184
Advanced “lab-on-a-chip” to detect viruses – Current challenges and future perspectives
Zhuang, J., Yin, J., Lv, S., Wang, B., & Mu, Y. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112291 · Cited by 158
Metadata
- Authors
- Kaarj, K., Akarapipad, P., & Yoon, J.-Y.
- Venue
- Scientific Reports
- Published
- 2018-08-20
- Volume
- 8
- Issue
- 1
- Pages
- 12438-12438
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2885281620
- Cited by
- 184
- References
- 22
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.