Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 220

The DOI matches its Crossref record.

Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads

Open access
Ziacchi, M., Diemberger, I., Corzani, A., Martignani, C., Mazzotti, A., Massaro, G., Valzania, C., Rapezzi, C., Boriani, G., Biffi, M. · 2018 · Scientific Reports

Abstract

We evaluated the performance of 3 different left ventricular leads (LV) for resynchronization therapy: bipolar (BL), quadripolar (QL) and active fixation leads (AFL). We enrolled 290 consecutive CRTD candidates implanted with BL (n = 136) or QL (n = 97) or AFL (n = 57). Over a minimum 10 months follow-up, we assessed: (a) composite technical endpoint (TE) (phrenic nerve stimulation at 8 V@0.4 ms, safety margin between myocardial and phrenic threshold <2V, LV dislodgement and failure to achieve the target pacing site), (b) composite clinical endpoint (CE) (death, hospitalization for heart failure, heart transplantation, lead extraction for infection), (c) reverse remodeling (RR) (reduction of end systolic volume >15%). Baseline characteristics of the 3 groups were similar. At follow-up the incidence of TE was 36.3%, 14.3% and 19.9% in BL, AFL and QL, respectively (p < 0.01). Moreover, the incidence of RR was 56%, 64% and 68% in BL, AFL and QL respectively (p = 0.02). There were no significant differences in CE (p = 0.380). On a multivariable analysis, “non-BL leads” was the single predictor of an improved clinical outcome. QL and AFL are superior to conventional BL by enhancing pacing of the target site: AFL through prevention of lead dislodgement while QL through improved management of phrenic nerve stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-31692-z

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 220

Metadata

Authors
Ziacchi, M., Diemberger, I., Corzani, A., Martignani, C., Mazzotti, A., Massaro, G., Valzania, C., Rapezzi, C., Boriani, G., & Biffi, M.
Venue
Scientific Reports
Published
2018-09-05
Volume
8
Issue
1
Pages
13262-13262
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2889074464
Cited by
220
References
0
FWCI
36.13
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads. https://app.cochat.ai/papers/10.1038/s41598-018-31692-z
The paper
Ziacchi, M., Diemberger, I., Corzani, A., Martignani, C., Mazzotti, A., Massaro, G., Valzania, C., Rapezzi, C., Boriani, G., & Biffi, M. (2018). Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads. Scientific Reports. https://doi.org/10.1038/s41598-018-31692-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.